DOI QR코드

DOI QR Code

Detection of Arrhythmias by Holter Monitoring and Use of Wearable Electrocardiography Devices Holter and wearable devices for arrhythmia detection

  • Ji Yeon Chang (Department of Biomedical Laboratory Science, Dankook University College of Health &Welfare) ;
  • Jae Kyung Kim (Dept. of Biomedical Laboratory Science, Dankook Univ.)
  • Received : 2023.04.05
  • Accepted : 2023.05.20
  • Published : 2023.06.30

Abstract

In this paper, we show that the limitations of Holter monitoring and Wearable Electrocardiogarphy Devices and their arrhythmia detection. Sudden death caused by cardiovascular disease, often referred to as the "silent killer" due to its unpredictable nature, is a major health concern. Electrocardiography (ECG) is a basic diagnostic tool for detecting heart disease, but its limitations make it difficult to detect arrhythmia, a significant indicator of an irregular heart state. To address this limitation, a long-term continuous ECG recording device has been developed, Holter ECG device and wearable device. A significant number of studies have focused on the differences between Holter monitoring and wearable devices. The Holter tests were useful for detecting regularly occurring arrhythmias, whereas wearable patches were better at detecting random and infrequent arrhythmias. Wearable patches were effective in detecting episodes of arrhythmia and myocardial ischemia. Despite the concern, wearable devices had less signal loss than Holter monitoring and patients also preferred wearable devices over Holter monitoring due to convenience. These results could mean that the wearable devices can perfectly replace the Holter test.

Keywords

References

  1. Q. Shen, J. Li, C. Cui, X. Wang, H. Gao, C. Liu, and M. Chen, "A wearable real-time telemom nitoring electrocardiogram device compared with traditional Holter monitoring," Journal of Biomedical Research, Vol. 35, No. 3, pp. 238-246, Dec 2020. https://doi.org/10.7555/JBR.34.20200074
  2. P. Kamga, R. Mostafa, and S. Zafar, "The use of wearable ECG devices in the clinical setting: a revie w," Current Emergency and Hospital Medicine Reports, Vol. 10, No. 3, pp. 67-72, Sep
  3. S. Ramasamy and A. Balan, "Wearable sensors for ECG measurement: a review," Sensor Review, Vol. 38, No. 4, pp. 412-419, Feb 2018. https://doi.org/10.1108/SR-06-2017-0110
  4. J. Hwang, J. Kim, K.J. Choi, M.S. Cho, G.B. Nam, and Y.H. Kim, "Assessing accuracy of wrist-worn wearable devices in measurement of paroxysmal supraventricular tachycardia heart rate,"Korean Circulation Journal, Vol. 49, No 5, pp. 437-445, May 2019. https://doi.org/10.4070/kcj.2018.0323
  5. S. Chaudhuri, T.D. Pawar, and S. Duttagupta, Ambulation analysis in wearable ECG, Springer, 2009.
  6. W. Choi, S.H. Kim, W. Lee, S.H. Kang, C.H. Yoon, T.J. Youn, and I.H. Chae, "Comparison of continuous ECG monitoring by wearable patch device and conventional telemonitoring device," Journal of Korean Medical Science, Vol. 35, No. 44, e363, Nov 2020.
  7. S. Majumder, L. Chen, O. Marinov, C.H. Chen, T. Mondal, and M.J. Deen, "Noncontact wearable wireless ECG systems for long-term monitoring," IEEE Reviews in Biomedical Engineering, Vol. 11, pp. 306-321, May 2018. https://doi.org/10.1109/RBME.2018.2840336
  8. M. Boszko, G. Osak, N. Zurawska, K. Skoczylas, B. Krzowski, G. Wroblewski, G., A. Maciejewski, J. Sobiech, S. Ostrowski, M. Grabowski, and L. Koltowski, "Assessment of a new KoMaWo electrode-patch configuration accuracy and review of the literature," Journal of Electrocardiology, Vol 75, pp. 82-87, No v-Dec
  9. K. Eguchi and R. Aoki, "Practical RR interval editing for heart rate variability analysis using single-channel wearable ECG devices," IEEE Access, Vol. 11, pp. 25543-25582, Mar 2023. https://doi.org/10.1109/ACCESS.2023.3253933
  10. H. Kamozawa, S. Muroga, and M. Tanaka, "A detection method of atrial fibrillation from 24-hour Holter-ECG using CNN," IEEJ Transactions on Electrical and Electronic Engineering, Vol. 18, No. 4, pp. 577-582, Apr 2023. https://doi.org/10.1002/tee.23756
  11. M. Strik, S. Ploux, D. Weigel, J. van der Zande, A. Velraeds, H.P. Racine, F.D. Ramirez, M. Haissaguerre, and P. Bordachar, "The use of smartwatch electrocardiogram beyond arrhythmia detection," Trends in Cardiovascular Medicine, Vol. S1050-1738, No. 22, 00153-0, Jan 2023.
  12. J. Hoevelmann, K. Sliwa, O. Briton, M. Ntsekhe, A. Chin, and C. Viljoen, "Effectiveness of implantable loop recorder and Holter electrocardiographic monitoring for the detection of arrhythmias in patients with peripartum cardiomyopathy," Clinical Research in Cardiology, Vol. 112, No. 3, pp. 379-391, Mar 2023. https://doi.org/10.1007/s00392-022-02101-3
  13. T. Todorov, G.T. Bogdanova, N. Noev, and N. Sabev, "Data management in a holter monitoring system," TEM Journal, Vol. 8, No. 3, pp. 801-805, 2019.
  14. S. Kwon, S.R. Lee, E.K. Choi, H.J. Ahn, H.S. Song, Y.S. Lee, and S. Oh, "Validation of adhesive single-lead ECG device compared with Holter monitoring among non-atrial fibrillation patients," Sensors, Vol. 21, No. 9, p. 3122, Apr 2021.
  15. S. Murali, N. Brugger, F. Rincon, M. Mashru, S. Cook, and J.J. Goy, "Cardiac ambulatory monitoring: new wireless device validated against conventional Holter monitoring in a case series," Frontiers in Cardio vascular Medicine, Vol. 7, 587945, Nov 2020.
  16. P. Vardas, M. Cowie, N. Dagres, D. Asvestas, S. Tzeis, E.P. Vardas, G. Hindricks, and J. Camm, "The electrocardiogram endeavour: from the Holter single-lead recordings to multilead wearable devices supported by computational machine learning algorithms," EP Europace, Vol. 22, No. 1, pp. 19-23, Jan 2020. https://doi.org/10.1093/europace/euz249
  17. Z. Cai, J. Li, X. Zhang, Q. Shen, A. Murray, and C. Liu, "How accurate are ECG parameters from wearable single-lead ECG system for 24-hours monitoring," 2019 Computing in Cardiology, pp. 1-4, Sep 2019.
  18. K. Amami, A. Yoshihisa, Y. Horikoshi, S. Yamada, T. Nehashi, N. Hijioka, M. Nodera, T. Kaneshiro, T. Yokokawa, T. Misaka, and Y. Takeishi, "Utility of a novel wearable electrode embedded in an undershirt for electrocardiogram monitoring and detection of arrhythmias," Plos One, Vol. 17, No. 8, e0273541, Aug
  19. Y.T. Tsukada, M. Tokita, H. Murata, Y. Hirasawa, K. Yodogawa, Y.K. Iwasaki, K. Asai, W. Shimizu, N. Kasai, H. Nakashima, and S. Tsukada, "Validation of wearable textile electrodes for ECG monitoring," Heart and Vessels, Vol. 34, No. 7, pp. 1203-1211, Jul 2019. https://doi.org/10.1007/s00380-019-01347-8
  20. M. Jacobsen, T.A. Dembek, A.P. Ziakos, R. Gholamipoor, G. Kobbe, M. Kollmann, C. Blum, D. MullerWieland, A. Napp, L. Heinemann, N. Deubner, N. Marx, S. Isenmann, and M. Seyfarth, "Reliable detection of atrial fibrillation with a medical wearable during inpatient conditions," Sensors, Vol. 20, No. 19, p. 5517, Sep 2020.
  21. A. Xintarakou, V. Sousonis, D. Asvestas, P.E. Vardas, and S. Tzeis, "Remote cardiac rhythm monitoring in the era of smart wearables: present assets and future perspectives," Frontiers in Cardiovascular Medicine, Vol. 9, 853614, Mar
  22. P. Wang, Z. Lin, X. Yan, Z. Chen, M. Ding, Y. Song, and L. Meng, "A wearable ECG monitor for deep learning based real-time cardiovascular disease detection," arXiv preprint arXiv:2201.10083, Jan 2022.