• Title/Summary/Keyword: Wear a health mask

Search Result 24, Processing Time 0.018 seconds

Study on the shouting breathing pattern while jogging wearing a mask

  • Tian, Zhixing;Bae, Myung-Jin
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.2
    • /
    • pp.130-135
    • /
    • 2021
  • Because of the COVID-19 epidemic, many countries have made the obligation to wear masks normal. Wearing masks in public places has become a must. At present, wearing a mask to participate in sports makes it very common. People seek to gain health through exercise but ignore the potential respirato-ry health threat. That is, wearing a mask will cause a decrease in oxygen content in the body. This neg-ative impact becomes more prominent as the wear-ing time and oxygen consumption increase. To pro-tect people from viruses and enjoy a healthy life. This paper proposes a breathing pattern that im-proves blood oxygen saturation while wearing a jogging mask and walking. Namely, shouting breathing pattern. Use a pulse oximeter to measure the blood oxygen saturation of running at different speeds and compare the normal breathing pattern and the shouting breathing pattern. The results show that the shouting breathing pattern has a sig-nificant improvement in the blood oxygen satura-tion of low-speed walking and medium-speed jog-ging.

Development of a Low Noisy Type of Air-line Mask (저소음형 송기마스크 개발)

  • Paik, Eun-Gyu;Kim, Bong-Nyun;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.277-281
    • /
    • 2005
  • Air-line mask is an important personal protective equipment for workers working under hazardous surroundings in which a fixed ventilation system is difficult to be installed. If the air-line mask make loud noise, works wearing the mask may be faced with health problems such as noise induced hearing loss(NIHL). The purpose of this study is to introduce a low noisy technology for workers using air-line mask. A traditional type air-line has been improved to an advanced air-line mask with lesser noise. In the mask, air suppling conduits consists of multi tubes are placed inside of the front of the safety helmet. The noise level reduced from 80dB(A) to less than 80dB(A) when measured by KS A 0701 method at Center for Safety Inspection, Testing and Certification for KOSHA. It is suitable for related regulation[Article 35 of the Industrial Safety and Health Act(Test of Personal Protective Equipment)]. While workers working in noise level of over 90dB(A), they may expose to 82dB(A) or less when they wear the advanced masks. This type masks can be an alternative for works suffering from loud noise generated by traditional air-line masks.

University students' perception of Health masks at the time of Transition from the COVID-19 pandemic to the Recovery stage for Daily life (코로나 19 팬데믹에서 일상생활로의 회복 단계로 전환되는 시점에서의 보건용 마스크에 대한 대학생의 인식)

  • Yeon-Hee Lee;Ok-Yul Yang
    • Journal of the Health Care and Life Science
    • /
    • v.10 no.1
    • /
    • pp.89-98
    • /
    • 2022
  • This study conducted a survey using a Google questionnaire targeting 380 male and female college students to find out the perceptions of college students about health masks at the time of transition from the COVID-19 pandemic to the recovery stage. As a result, at the time when the obligation to wear an outdoor mask was relaxed, they still wore an outdoor mask (3.63±1.34). As for the reasons for wearing a mask, 27.8% said 'wearing a mask became a habit' and 'fear of infection' was 19.4%. Hand washing to prevent COVID-19 was observed well (4.07±1.00), and when infection was suspected, they showed an attitude of checking for infection with a home kit or rapid antigen test (3.88±1.17). In addition, it was recognized that COVID-19 is not threatening (3.19±1.28) and that it will recover easily after infection (3.19±1.28). In a situation where the number of COVID-19 infections continues to decrease, the government is pushing for a gradual recovery of new daily life. Therefore, it is necessary to provide correct information that affects individual awareness and to promote it through various media, and I would like to emphasize the importance of education on the autonomous practice of individual quarantine rules.

A Study on the Actual Wearing Status of Health Masks - Focusing on College Students in Their 20s - (보건용 마스크의 착용실태에 관한 연구 - 20대 대학생을 중심으로 - )

  • Hayoung Song;Kyong-Hwa Yi
    • Journal of Fashion Business
    • /
    • v.27 no.2
    • /
    • pp.52-69
    • /
    • 2023
  • Based on five types of health KF masks currently being commercialized, this study analyzed results of a survey of 316 male and female college students with experience in wearing health masks in Seoul metropolitan area. By identifying problems and improvement requirements according to current status of wearing health masks, results of this study could be used as basic data for designing ergonomic health mask with improved ease of wearing and satisfaction for human safety protection in the future. SPSS 26.0 statistical program was used for all data analyses, including post-hoc test, χ2 test for cross-analysis, frequency analysis, independent samples t-test, ANOVA, and Duncan test. Considering that masks are worn for more than 8 hours a day on average, it is necessary to design masks considering materials, sizes of mask ear straps, elasticity and thickness of straps. The design should minimize contact with lips and cheeks with improved fit and comfort, blocking performance, and aesthetics. According to this survey, nearly 50% of respondents said they were willing to wear masks even after the end of COVID-19. Thus, it is necessary to perform research and improve masks to have excellent colors, designs, shapes, fit, and functions suitable for both pandemic and post-pandemic era when wearing masks is common.

Evaluation of the Filtration Efficiency and Facial Inhalation Resistance of Various Commercial Masks (시중에 판매되는 다양한 비인증 마스크의 분진 포집효율과 안면부 흡기저항 평가)

  • Kang, Sohyun;Kim, Soomin;Yoon, Chung Sik;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.3
    • /
    • pp.292-301
    • /
    • 2021
  • Objectives: Wearing medical masks has been recommended since the declaration of coronavirus disease-19 (COVID-19) as a pandemic disease. Certified medical masks are evaluated according to filtration efficiency and facial inhalation resistance. However, some people use non-certified common masks. This study aimed to evaluate various non-certified commercial masks based on the certification criteria for medical masks. Methods: Twenty mask products (three anti-droplet, three disposable dental, eight fashion, three cotton, and three children's masks) were selected. For performance evaluation, filtration efficiency and facial inhalation resistance tests were conducted. The evaluation method followed the certification method for KF-certified masks of the Ministry of Food and Drug Safety (MFDS) and the N95 respirator of the National Institute for Occupational Safety and Health (NIOSH). Results: None of the 20 masks met the KF94 certification standard set by the MFDS. Four and three masks respectively met the KF80 certification standard and the N95 standard of NIOSH. Filtration efficiency was significantly higher in three-layer masks than in single layer masks. Pleated-type masks had higher filtration efficiency than cone-type masks. There was no correlation between the structure of masks and facial inhalation resistance. Conclusion: While no masks complied with the KF94 certification standard, a few masks met the KF80 and the N95 certification standards of NIOSH. Although some people wear non-certified commercial masks, protection from aerosols is not guaranteed by such masks. Evaluation of the protection efficiency of non-certified mask against microbiological infection is needed for the prevention of infectious disease.

Effect of Mask Wearing and Type on Cardiopulmonary Resuscitation Accuracy, Fatigue and Physiological Changes

  • Sung-Hwan Bang;Hyo-Suk Song;Gyu-Sik Shim;Hee-Jeong Ahn
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.113-120
    • /
    • 2023
  • The purpose of this study was the accuracy of cardiac compression, fatigue, and physiological changes of the rescuer for different mask type in cardiopulmonary resuscitation(CPR). Data collection was from 9 to 12 May 2022, the participants were a total of 24 paramedic students with a BLS provider at D University. The students participated in an experiment in which 12 students each wore a surgical mask (Dental mask) and a fine particle 94% blocking mask (KF94 mask) and performed CPR for 2 minutes over a total of 7 times. As a result of the study, in the analysis of the quality of the rescuer's chest compression according to the type of mask, there was a significant difference in the compression speed (F=24.91, p<.001) and bad compression hand position (F=14.54, p=.024) in the group wearing the KF94, Fatigue showed significant differences in both the Dental mask group (F=51.16, p<.001) and the KF94 mask group (F=63.49, p<.001). Among the physiological changes, heart rate showed a significant difference between the Dental mask group (F=34.79, p<.001) and the KF94 mask group (F=35.55, p<.001), and the respiratory rate showed a significant difference between the Dental mask group (F=25.02, p=.001) and the KF94 mask group(F=23.02, p=.002). Therefore, in order to improve the quality of efficient chest compression and reduce the fatigue and physiological changes of rescuers, it will be necessary for rescuers to wear suitable personal protective equipment.

Development and Performance Evaluation of Air-Supplied Mask (분진의 인체내 유입을 차단하기 위한 송기 마스크의 개발 및 성능평가)

  • Kim, Min Cheol;Kim, Hyun Tae;Lee, Kyoo Won
    • Clean Technology
    • /
    • v.4 no.1
    • /
    • pp.60-67
    • /
    • 1998
  • As workers' health and welfare are becoming increasingly important, there are needs for protecting workers from being exposed to dust particles in workplace. One of the simplest ways to protect workers is to wear a one-time-use mask of the 3M type. Although conventional masks are convenient to use, they provide low filtration efficiency simply because of air leaks through interface between the face and the mask. In this study, a new type of mask is developed and tested. The air which is filtered first using high efficiency particulate air(HEPA) filter is supplied to the nose area of workers' face. The developed mask was tested for filtration efficiency and for workers' acceptance. Very good results were obtained for both accounts.

  • PDF

Radon Blocking Effect of Mask used in Everyday Life (일상생활에서 사용하는 마스크의 라돈 차단 효과)

  • Cheon, Se-Hyeon;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.313-318
    • /
    • 2020
  • Since radon is an inert gas and is a monoatomic molecule, the size of one particle represents the size of an atom, which means that it has a radius of approximately 1 to 100 nm. Therefore, if the mask has a radius smaller than the size of general fine dust and ultra fine dust, but it is possible to block the inhalation of radon more than a certain amount, it is considered that the exposure through the inhalation of radon can be reduced through normal indoor wear. Accordingly, we would like to find out the radon blocking effect of a mask worn in everyday life. Looking at the reduction rate of radon for each mask, cotton masks decreased by 33.45%, medical masks by 33.50%, KF 80 masks by 35.12%, and KF 94 masks by 37.72%. It was found that the radon blocking effect of the cotton and medical masks was somewhat inferior to that of the KF mask, but the difference was not so great that the introduction of radon into the air could be blocked to a certain level by wearing a mask.

Study On Masked Face Detection And Recognition using transfer learning

  • Kwak, NaeJoung;Kim, DongJu
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.294-301
    • /
    • 2022
  • COVID-19 is a crisis with numerous casualties. The World Health Organization (WHO) has declared the use of masks as an essential safety measure during the COVID-19 pandemic. Therefore, whether or not to wear a mask is an important issue when entering and exiting public places and institutions. However, this makes face recognition a very difficult task because certain parts of the face are hidden. As a result, face identification and identity verification in the access system became difficult. In this paper, we propose a system that can detect masked face using transfer learning of Yolov5s and recognize the user using transfer learning of Facenet. Transfer learning preforms by changing the learning rate, epoch, and batch size, their results are evaluated, and the best model is selected as representative model. It has been confirmed that the proposed model is good at detecting masked face and masked face recognition.

Fit Tests for Second-class Half Masks (2급 방진마스크 밀착도 평가)

  • Cho, Kee Hong;Kim, Hyun Soo;Choi, Ah Rum;Chun, Ji Young;Kang, Tae Won;Kim, Min Su;Park, Kyeong Hak;Kim, Ze One
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.146-152
    • /
    • 2022
  • Objectives: The purpose of this study is to confirm whether there is a factor to affect the evaluation of fit test of a 2nd class half masks using a OPC test method. Methods: Total 34 adults including Males and Females were tested using OPC-based fit testing equipment while wearing a 2nd class half filtered mask. Results: 1. The result of measuring face dimensions using different tools such as a 3D scanner and digital calipers revealed that the variation of lip width was not statistically significant because there was only a difference of about 4 mm. However, it showed that a difference in face length was statistically significant enough with 10 mm(p<0.000). 2. The fit factor for each exercise stage according to gender was the highest at 124.54(p<0.001) in Step 3, and the fit factor was the lowest at 73.75 in Step 1. 3. In the evaluation of the degree of fit factor according to gender, female passed 67.44%, which was higher than the value in male(p<0.038). 4. The acceptance rate of the group having a face length of shorter than 110 mm was 91.67%. On the other hand, the acceptance rate of the group with a face length of longer than 110 mm was 47.27%(p<0.000). 5. The fit test was possible because the fit factor with 2nd class half masks corresponding to FFP1(Filtering Face Piece 1) was passed 55% or more. Conclusions: The test results showed that using a 2nd class half filtered mask, it is important to wear a properly designed mask so that face size does not affect the fit factor.