• Title/Summary/Keyword: Waterproof test

Search Result 153, Processing Time 0.024 seconds

Development and Application of Unit Table Form using Euro Form for High-rise Building Construction (연질 및 경질 초속경도막방수재를 복합화한 옥상노출방수공법에 관한 실험적 연구(구조물 거동 대응성))

  • Choi, Eun-Kyu;Seo, Hyun-Jae;Kim, Bum-Soo;Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.141-142
    • /
    • 2017
  • New waterproofing technologies have emerged in the field of building waterproofing due to the recent diversification of the size and type of structures, the enhancement of required performance, and the diversification of new technologies (such as materials and methods)(Sheet waterproofing material, coating waterproofing material) is reduced, and composite waterproofing materials that utilize mutual benefits are widely used by compounding them (sheet+coating film, coating film+sheet). However, it is true that there is no evaluation method that can verify these composite waterproof materials, which is the most widely used at present, but the KS standard only specifies tests for individual materials However, there is a situation in which the countermeasures without a test method for composite waterproofing become sudden.

  • PDF

Analysis of finishing details to Prevent leakage of PC Apartment Joints in Korea (국내 PC 아파트 접합부 누수 방지를 위한 마감상세 분석)

  • Kim, Tae-Ho;Ko, Hyo-Jin
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.4
    • /
    • pp.81-89
    • /
    • 2021
  • Recently, interest in OSC(Off Site Construction) is increasing due to the trend of a decrease in skilled workers and an increase in labor costs. In this regard, PC(Precast Concrete) is being reviewed for apartments, the most common type of housing in Korea. As the biggest concern for PC apartment houses, civil complaints such as inter-floor noise and leakage were presented. In this study, the details of the joints were reviewed based on the past cases of PC apartments, and the details of the recently constructed or planned PC apartments were investigated. Through this, the leakage path in the past was analyzed through the existing research literature and data. And wall type RC and PC apartment joint leakage test was performed and we found the needs for a detail of waterproof steps, sealant. Also, joint details were investigated for a rahmen type apartment housing under construction. At last, A discussion was conducted on the direction for a detailed proposal of an improved joint in the future.

Analysis of underground post-tensioned precast concrete box utility tunnel under normal fault displacement

  • Wu, Xiangguo;Nie, Chenhang;Qiu, Faqiang;Zhang, Xuesen;Hong, Li;Lee, Jong-Sub;Kang, Thomas H.K.
    • Computers and Concrete
    • /
    • v.29 no.2
    • /
    • pp.69-79
    • /
    • 2022
  • For long underground box utility tunnels, post-tensioned precast concrete is often used. Between precast tunnel segments, sealed waterproof flexible joints are often specified. Fault displacement can lead to excessive deformation of the joints, which can lead to reduction in waterproofing due to diminished contact pressure between the sealant strip and the tunnel segment. This paper authenticates utilization of a finite element model for a prefabricated tunnel fault-crossing founded on ABAQUS software. In addition, material parameter selection, contact setting and boundary condition are reviewed. Analyzed under normal fault action are: the influence of fault displacement; buried depth; soil friction coefficient, and angle of crossing at the fault plane. In addition, distribution characteristics of the utility tunnel structure for vertical and longitudinal/horizontal relative displacement at segmented interface for the top and bottom slab are analyzed. It is found that the effect of increase in fault displacement on the splice joint deformation is significant, whereas the effects of changes in burial depth, pipe-soil friction coefficient and fault-crossing angle on the overall tunnel and joint deformations were not so significant.

SPF Measurement and Cytotoxicity of Sunscreen Agents in Cosmetic (화장품에서 UV 차단제의 피부 자극성과 SPF 측정)

  • Kim, In-Young;Kang, Sam-Woo
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.79-87
    • /
    • 1998
  • Consumers have recently preferred to purchase extensive UV intercepting products, which are waterproof and free from side effects on skin. During the testing of cytotoxicity (in-vitro) in neutral red (NR) method, cell survival ratio of UV-B interceptors decreased to just above 0.08 w/v%, and it was observed that the UV-A interceptors the ratio also decreased to just above 0.06 w/v%. In addition patch-tests of inorganic UV interceptors resulted in no skin irritation even below 10.0 and 11.25. In absorption curves, UV-B was most suitable for octyl methoxycinnamate (OMC) and UV-A for butyl methoxy dibenzoylmethane (BMDM). For this reason, $Nylonpoly^{TM}$ UVA/UVB the material of OMC and BMDM coated with Nylon & polyethylene, was used as the organic UV interceptor. Zinc oxide (ZnO) and titanium dioxide ($TiO_2$) was used as inorganic UV interceptors. The appropriate mixture ratio of ZnO and $TiO_2$ was 6 to 4:6% of ZnO, 4% of $TiO_2$ and 5% of $Nylonpoly^{TM}$ UVA/UVB were all combined and added to our sunscreen cream. The SPF value of in-vitro was 38.9. In practical application, each sun protection factor (SPF) duration of oil-in-water (O/W) emulsion and water-in-silicone (W/S) emulsion containing sunscreen cream of the same content showed that W/S type of sunscreen cream was 5 times as durable as the other. Therefore, this product is fit for use in swimming, climbing or skiing. This research is to minimize skin trouble caused by UV interceptors and to make one with proper softness, skin safety and UV intercepting efficiency.

  • PDF

A Study on Improvement of Modular Specifications - Focused on technical specifying method in waterproof and mechanical works - (모듈러 공사시방서 개선방안에 관한 연구 - 방수 및 기계설비공사의 기술방안 개선을 중심으로 -)

  • Yoon, Jongsik;Shin, Dongwoo;Cha, Heesung;Kim, Kyungrai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.3
    • /
    • pp.33-41
    • /
    • 2017
  • A modular specification is a contract document that specifies the requirements of production, transformation and installation in a modular construction. A problem of the currently used specification is that it does not guarantee the level of performance required by the modular construction and fails to accommodate unique characteristics of each construction because it widely uses the standard specification as it is. This study proposes a specification that reflects the unique feature of modular construction in order to improve the quality of modular construction. Research focuses on the leakage in waterproof and mechanical equipment because it is the area with the highest rate of defects. This study suggests ways to improve the modular specification as follows: 1)Descriptive specifying (following MasterFormat) 2)Propose leakage verification method and test clause 3) Reflect characteristic of modular construction. Proposed modifications to modular specification are reviewed by experts for validation and their opinion verifies suggested improvements as a way to secure the quality of modular construction and to promise characteristics of the modular specification. This improvement will be used for reference when writing construction project specification, which can be an important contract document, so that it could lower occurrence rate of the modular defects.

Development and Applicability Evaluation of High Performance Poly-urea for RC Construction Reinforcement (RC 구조물 보강을 위한 고성능 폴리우레아의 개발 및 적용성 평가)

  • Kim, Sung Bae;Kim, Jang-Ho Jay;Choi, Hong-Shick;Heo, Gweon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2A
    • /
    • pp.169-176
    • /
    • 2010
  • Generally, poly-urea is widely used as waterproof coating material due to its superior adhesiveness, elongation capacity, and permeability resistance. In addition, it can be quickly and easily applied on structure surfaces using spray application. Since it hardens in about 30 seconds after application, its construction efficiency is very high and its usage as a special functional material is also excellent. However, currently, poly-urea is mostly used as waterproof coating material and the researches on its usage as a retrofitting material is lacking at best. Therefore, basic studies on the use of poly-urea as a general structural retrofitting material are needed urgently. The objective of this study is to develop most optimum poly-urea composition for structure retrofitting purpose. Moreover, the structural strengthening capacity of the developed poly-urea is evaluated through flexural capacity experiments on RC beams and RC slabs. From the results of the flexural test of poly-urea strengthened RC beam and slab specimens, the poly-urea and concrete specimen showed monolithic behavior where ductility and ultimate strength of the poly-urea strengthened specimen showed slight increase. However, the doubly reinforced specimens with FRP sheet and poly-urea showed lower capacity than that of the specimen reinforced only with FRP sheet.

A Study on the Ground Reinforcement of Jeju Scoria Layer by Chemical Grouting (약액주입에 의한 제주도 송이지층의 지반보강에 관한 연구)

  • Yang, Kiho;Park, Jeongjun;Kim, Younghun;Byun, Yoseph;Lee, Eunjong;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.75-82
    • /
    • 2014
  • Recently, public works becoming bigger in Jeju are implemented various kinds of ground reinforcement method including the chemical grouting method. In this study, we have been investigated on the proper material and the injection condition for the excellent injection effect and the excellent strength of injection material and the permanent waterproof and reinforcement through the experiment. The kind of injection material has been selected through the uniaxial compression test and the endurance test of injection material as the chamber test. An experiment was performed with model ground made of scoria, the injection performance of selected material has been identified through the evaluation test of injection range using the decision test of injection amount and the calibration chamber test. As a result of test, it has been analyzed that MSG appeared to have the excellent strength, durability and injection performance all compared with the ordinary cement, this result is judged to be possible as the ancillary data of design at time of design and construction with the chemical grouting method in the future.

A Study on Examination of Application in Waste Filled Land and Performance Evaluation as Waterproofing Material by the Spray Water-Soluble Rubber Asphalt (뿜칠형 수용성 고무화 아스팔트 차수재의 성능평가 및 폐기물 매립지 적용성 검토에 관한 연구)

  • 오상근;김형무;정문정;최은수
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.165-173
    • /
    • 2001
  • This study examinated the application in construction field and the development of waterproofing material system by the spray water-soluble rubber asphalt to solve the problems of synthetic polymer sheet and gio membrane(A mat sheet of Bentonite) that had been used domestic waterproofing material in advance. As the result of study, characters of study water-soluble rudder asphalt are the follows: 1) The amount of water absorption was '0.06'g and the seepage quality was '0'g in result. 2) The tensile strength was about 30.7kgf/$\textrm{cm}^2 and the elongation was about 72.4% in result. 3) After reliance of temperature test had been ended, the tensile strength was about 72.4kgf/$\textrm{cm}^2 in low temperature and about 30.7kgf/$\textrm{cm}^2 in normal temperature. 4) After acid and alkaline treatment had been ended, the tensile strength was about 19.7kgf/$\textrm{cm}^2$ and about 21.9kgf/$\textrm{cm}^2 in result. 5) After chlorine ion treatment had been ended, the tensile strength was 28.5kgf/$\textrm{cm}^2$ and the elongation was 250% in result. 6) The impact performance was subsided at 1.5m height. 7) After promotion weathering had been ended, the tensile and elongation was about 26.0kgf/$\textrm{cm}^2, 214% in result. So, this study can propose the spray water-soluble rubber asphalt to satisfy the and durability of waste filled land.

  • PDF

A Study on Assessment Techniques of Levee Safety (하천제방의 안전성 평가기법 연구)

  • Yoon Jong-Ryeol;Kim Jin-Man;Choi Bong-Hyuck
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.111-116
    • /
    • 2005
  • 2-D and 3-D resistivity surveys were carried out at the Deok-In2 levee during the period of arid and rainy seasons to assess the waterproof effectiveness of sheet pile and grouting sections and detect the location of pipings. Inverted resistivity sections clearly indicated the boundaries of sheet pile and grouting sections and the locations of pipings observed at the ground surface. Besides, GPR survey was carried out to verify the rear cavity of culvert in levee which is thought to be the major cause of levee breakdown, But the quality of GPR data was very poor due to the steel reinforcements buried in the culvert. Because it is not easy to apply various geophysical surveys upon concrete structures, newly designed hydraulic response test was proposed to assess the continuity of rear cavity of culvert in this study.

  • PDF

Examination of Development State of Smart Fiber in Korean Textile Industry - Focused on Companies in Daegu/North Gyeongsang Province - (한국 섬유기업의 스마트섬유 개발 동향 - 대구경북지역 업체를 대상으로 -)

  • Yoo, Hwa-Sook;Park, Kwang-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.8
    • /
    • pp.1262-1272
    • /
    • 2007
  • The purpose of this study was to examine the development trend of smart fiber by textile companies in Daegu/North Gyeongsang Province. This examination includes the development fields of smart fiber, investment size, information sources and the use degree of those, research-related infrastructure, relationship between companies' characteristics and their interests in smart fiber. Research data were collected by a survey. The definition and classification(4 areas and 12 development products) of smart fiber followed ones of Smart Fiber Technology Roadmap by the Ministry of Commerce, Industry and Energy. Data were analyzed using SPSS 11.0 program for frequency, means, t-test, and $X^2$-test. Among respondents, the numbers of dying and finish companies and export traders were the highest. It revealed that 19.6% of companies were developing smart fibers. Within 12 development products, vapor permeable/waterproof fiber showed to be most being developed, while medical fiber for human has not been developed and wasn't made an investment plan for developing. It was discovered that the biggest problem of smart fiber development was the lack of experts and the best outcome of smart fiber development was preoccupation of future market. It showed that companies got information from textile fairs but didn't often use information sources. The companies appeared to have a weak intention about research of smart fiber. The more important a company considered functionality of textile products and the more innovative and stabler the company was, the higher interest in smart fiber companies had. It was concluded that textile companies in Daegu/North Gyeongsang Province were aware of the importance of smart fiber development but they were not strongly interested in it and not enthusiastic in taking action on it.