• Title/Summary/Keyword: Waterproof Grade

Search Result 8, Processing Time 0.021 seconds

Seam Characteristics of Breathable Waterproof Fabrics with Various Finishing Methods

  • Jeong, Won-Young;An, Seung-Kook
    • Fibers and Polymers
    • /
    • v.4 no.2
    • /
    • pp.71-76
    • /
    • 2003
  • We evaluated the seam characteristics with finishing, seaming and sealing processes and seam Puckering behavior of the breathable waterproof fabrics with laser scan. There were differences in 99% significant level between the seamed fabric and the sealed fabric. Seam breakage was initiated with the breakage of sewing thread, so the seam strength after seaming was almost uniform. The sewn seam strength and elongation increased with sealing process in all finishing methods. Pucker grade of laminating type was generally much higher than that of the coating type. We confirmed that wave length and amplitude have more important meaning than the number of weave in the breathable waterproof fabrics. The puckering in breathable waterproof fabrics is mainly occurred by inherent and feeding pucker. The former if due to the insertion of sewing thread and the littler is caused by differential feeding when two pieces of fabric are fed into the gap between a press foot and needle plate.

An analysis of the Factors Influencing Leakage of Below-Grade Concrete Structures in Residential Buildings -Survey Centered Data- (공동주택 지하구조물 누수발생 요인에 대한 의견 분석 -설문조사를 중심으로-)

  • An, Ki-Won;Kang, Hyo-Jin;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.73-74
    • /
    • 2017
  • Below-grade concrete structure in residential buildings are exposed to various cracking conditions in between installation, construction and usage. Leakage follows the cracks along the exterior wall and floor slabs, and leakage occurring in this conditioning brings about discomfort to the users inside the building. This study analyzes a survey on the causes of leakage in below-grade concrete structure and proposes a solution method.

  • PDF

A Basic Study on the Evaluation Factor for Deteriorated Level of Rural House (농촌주택의 노후도 평가요소 도출을 위한 기초연구)

  • Park, Gil-Beom;Park, Jun-Mo;Kim, Ok-Kyue
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.107-108
    • /
    • 2014
  • The rural area has aged and depressed for urban area in Korea. Furthermore, the rural house has deteriorated and is vulnerable to disaster which collapse, fire, landslide, and so on. For this matter, it need to an evaluated system for deteriorated level of rural house. The evaluated system has a repairing method and an estimated cost for rural house to offer native in rural area. This study could draw evaluation factor for deteriorated level of rural house as a basic study for the evaluated system. The evaluation factors is compared the Korean housing performance grade indication system, the Korean green building certification criteria, and the Japanese housing performance indication system. As a result, they could eight types. There are a mothproof, an waterproof, a finishing material, an asbestos cement slate of roofing, a mobility right, an opening and closing of doors and windows, an indoor environment.

  • PDF

Analyses on Environment-friendliness of Root Barrier Materials based on Fish Toxicity Test (어독성 실험에 따른 방근재 친환경 특성 분석)

  • Woo, Ji-Keun;Kim, Sung-Kyun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.4
    • /
    • pp.42-51
    • /
    • 2010
  • The purpose of this study is to analyze the characteristics of environment-friendliness of Root Barrier materials based on comprehensive experiments on harmfulness of Root Barrier materials and fish toxicity of Oryzias latipes mortality to verify eco-toxicity of each method of construction and Root Barrier material, which are to be applied by taking eco-toxicity into account when building ecological flows in upper areas on natural and artificial grounds. As a result, the following conclusions have been reached in this study: 1. In regard of the harmfulness analyzed, each material showed a different result of analytical value in each lab tank. Compared to lab tank, pH (la), DO (lb), T-N (VI) and T-coli (la) were in the same grade, but COD, SS, T-P and F-coli were less than that of control, respectively increased or decreased by material were analyzed. 2. In the experiment of fish toxicity, Barrier sheet was found to have 66.7% of fish mortality, indicating strong fish toxicity. Synthetic rubber system root barrier sheet (20.0%) was analyzed to have medium fish toxicity, while Synthetic resin system root barrier-waterproof sheet (3.3%), Synthetic rubber system membrane root barrier sheet (3.3%) and Synthetic resin system root barrier sheet (0.0%) showed relatively lower mortality and fish toxicity. To sum up such results as found in the experiment mentioned so far, the values of harmfulness and root penetration resistance analyzed were different in each lab tank, but there was absolutely little correlation with the mortality gained from the experiment on fish toxicity. In the experiment of fish toxicity, environment-friendly root barrier materials were analyzed, and it was found that Synthetic resin system root barrier sheet, Synthetic resin system root barrier waterproof sheet and Synthetic rubber system membrane root barrier sheet are highly environment-friendly. In contrast, Synthetic rubber system root barrier sheet was found to have medium-level environment-friendliness. Also, Barrier sheet was analyzed to have low environment-friendliness.

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.

Development of New Ocean Radiation Automatic Monitoring System (새로운 해양 방사선 자동 감시 시스템의 개발)

  • Kim, Jae-Heong;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.743-746
    • /
    • 2019
  • In this paper we proposed a new ocean radiation automatic monitoring system. The proposed system has the following characteristics: First, using NaI + PVT mixed detectors, the response speed is fast and precision analysis is possible. Second, the application of temperature compensation algorithm to scintillator-type sensors does not require additional cooling devices and enables stable operation in the changing ocean environment. Third, since cooling system is not needed, electricity consumption is low, and electricity can be supplied reliably by utilizing solar energy, which can be installed at the observation deck of ocean environment. Fourth, using GPS and wireless communications, accurate location information and real-time data transmission function for measurement areas enables immediate warning response in the event of nuclear accidents such as those involving neighboring countries. The results tested by the authorized testing agency to assess the performance of the proposed system were measured in the range of $5{\mu}Sv/h$ to 15mSv/h, which is the highest level in the world, and the accuracy was determined to be ${\pm}8.1%$, making normal operation below the international standard ${\pm}15%$. The internal environmental grade (waterproof) was achieved, and the rate of variation was measured within 5% at operating temperature of $-20^{\circ}C$ to $50^{\circ}C$ and stability was verified. Since the measured value change rate was measured within 10% after the vibration test, it was confirmed that there will be no change in the measured value due to vibration in the ocean environment caused by waves.

Development of flow measurement method using drones in flood season (II) - application of surface velocity doppler radar (드론을 이용한 홍수기 유량측정방법 개발(II) - 전자파표면유속계 적용)

  • Lee, Tae Hee;Kang, Jong Wan;Lee, Ki Sung;Lee, Sin Jae
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.11
    • /
    • pp.903-913
    • /
    • 2021
  • In the flood season, the measurement of the river discharge has many restrictions due to reasons such as budget, manpower, safety, convenience in measurement and so on. In particular, when heavy rain events occur due to typhoons, etc., it is difficult to measure the amount of flood due to the above problems. In order to improve this problem, in this study, a method was developed that can measure the river discharge in a flood season simply and safely in a short time with minimal manpower by combining the functions of a drone and a surface velocity doppler radar. To overcome the mechanical limitations of drones caused by weather issues such as wind and rainfall derived from the measurement of the river discharge using the conventional drone, we developed a drone with P56 grade dustproof and waterproof performance, stable flight capability at a wind speed of up to 36 km/h, and a payload weight of up to 10 kg. Further, to eliminate vibration which is the most important constraint factor in the measurement with a surface velocity doppler radar, a damper plate was developed as a device that combines a drone and a surface velocity Doppler radar. The velocity meter DSVM (Dron and Surface Veloctity Meter using doppler radar) that combines the flight equipment with the velocity meter was produced. The error of ±3.5% occurred as a result of measuring the river discharge using DSVM at the point of Geumsan-gun (Hwangpunggyo) located at Bonghwang stream (the first tributary stream of the Geum River). In addition, when calculating the mean velocity from the measured surface velocity, the measurement was performed using ADCP simultaneously to improve accuracy, and the mean velocity conversion factor (0.92) was calculated by comparing the mean velocity. In this study, the discharge measured by combining a drone and a surface velocity meter was compared with the discharge measured using ADCP and floats, so that the application and utility of DSVM was confirmed.