철도차량용 전동기의 과제 (The Development of A.C. Induction Motor for Electric Railway Rolling Stock)

  • 윤승진;이인우;성기대;하현성;노철웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.24-26
    • /
    • 1995
  • The Development of A.C. Induction Motor for Railway Rolling Stock. The traction motor is designed as 4-pole induction motor with self ventilation. The winding insulation is throughout of materials of class C. The rotor is designed as a squrrel rotor with copper bar and casting. The rotor speed is detected by means of a pulse generator. The newer tection motor have no casting(frame). Punched-in holes make up the air duct and transfer the heat losses in complete. Maximim motor rpm is higher due to rotor construction. New is the entry of water-cooled traction motors in urban, However the water cooling design in - unfortunately - not applicable in traction motor.

  • PDF

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.

1MW 급 산업용 고온초전도 모터 특성 평가 (Performance Test of 1MW class High-temperature Superconducting Motor for Industry Application)

  • 백승규;권영길;김종무;이재득;이언용;김영춘;문태선;박희주;권운식;박관수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.142-143
    • /
    • 2007
  • A 1MW class HTS(High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of Neon thermosiphon mechanism and the stator coil is cooled by water through hollow copper conductor. This paper describes performance test results of our motor, which was conducted at steady state in generator mode and motor mode.

  • PDF

소듐냉각 고속로용 증기발생기 기술분석 및 개념개발 (Concept Development and Review of Current Technical Issues for SFR Steam Generator)

  • 남호윤;김종범;이재한;박창규
    • 대한기계학회논문집A
    • /
    • 제35권9호
    • /
    • pp.1083-1090
    • /
    • 2011
  • 소듐냉각 고속로를 개발함에 있어 최대 현안 중 하나가 증기발생기에서의 소듐-물 반응사고 가능성이다. 이를 개선하기 위해 지금까지 수십 종 이상 연구개발 되었지만 국가마다 그 사양이 다르고, 동일한 기종이 후속기에 다시 활용되지 못할 정도로 기술이 안정화 상태에 도달하지 못하였다. 최근 개발되고 있는 증기발생기의 공통적 목표는 소듐-물 반응사고의 조기감지 및 제어, 증기발생기의 검사 및 보수가 쉽게 용접개수를 줄이고 경제성을 높인 Benson 증기사이클을 적용하는 것이다. 이 논문에서는 지금까지 설계 또는 활용한 증기발생기들의 사양과 문제점을 비교, 분석하였고, 이를 토대로 현안 극복방안을 제시하였다.

이차목 디퓨저와 이젝터를 사용한 고공환경모사장치 예비설계 (Preliminary Design of a High Altitude Test Facility using a Secondary Throat Exhaust Diffuser and an Ejector)

  • 김중일;전준수;김태완;고영성;김선진;김유;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.475-478
    • /
    • 2012
  • 케로신과 액체산소를 추진제로 하는 로켓엔진의 고공환경모사를 위한 실험 장치의 예비 설계를 수행하였다. 고공환경모사를 위한 장치는 진공챔버, 초음속디퓨저, 열교환기, 이젝터, 증기 발생기로 구성된다. 로켓엔진을 장착한 진공챔버는 이차목 초음속 디퓨저에 의해 고공환경의 압력이 모사되고 이를 유지한다. 로켓엔진의 메인 연소가스는 열교환기에서 물로 냉각되며 이로 인한 혼합물은 이젝터로 인해 대기 중으로 배출된다. 이젝터는 75% 에탄올과 액체산소, 물로 작동하는 증기 발생기에 의해 작동되며 초기 진공도를 유지하는 역할을 한다.

  • PDF

A Numerical Design and Feasibility Study of Self-Wastage Experiment Using Simulant Material in a Sodium Fast Reactor

  • Jang, Sunghyon;Takata, Takashi;Yamaguchi, Akira
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.368-375
    • /
    • 2016
  • A sodiume-water reaction takes place when high-pressured water vapor leaks into sodium through a tiny defect on the surface of the heat transfer tube in a steam generator of the sodium-cooled fast reactor. The sodiume-water reaction brings deterioration of the mechanical strength of the heat transfer tube at the initial leakage site. As a result, it damages the crack itself, which may eventually enlarge into a larger opening. This self-enlargement is called "self-wastage phenomenon." In this study, a simulant experiment was proposed to reproduce the self-enlargement of a crack and to evaluate the mechanism of the self-wastage. The damage on the surface of the crack was simulated by making the neutralization reaction with hydrochloric acid solution and sodium hydroxide solution. A numerical investigation was carried out to validate the feasibility of the approach and to determine experimental conditions. From the computation results, it is observed that when 5M HCl is injected into 5M of NaOH with 0.05 m/s inlet velocity, the temperature at the surface near the crack increased over 319.26 K. The computational results show that the self-wastage phenomenon is capable of being reproduced by the simulant experiment.

Development of Wound Rotor Synchronous Motor for Belt-Driven e-Assist System

  • Lee, Geun-Ho;Lee, Heon-Hyeong;Wang, Qi
    • Journal of Magnetics
    • /
    • 제18권4호
    • /
    • pp.487-493
    • /
    • 2013
  • The automotive industry is showing widespread interest in belt-driven electric motor-assisted (e-Assist) systems. A belt-driven assist system (BAS) starts and assists the combustion engine in place of the conventional generator. In this study, a water-cooled wound rotor synchronous motor (WRSM) for the e-Assist system was designed and analyzed. The performance of the WRSM was compared with that of an interior permanent magnet synchronous motor (IPMSM). The WRSM efficiency can be improved for the BAS by adjusting the field flux at high speeds. The field current map to obtain the maximum efficiency based on the speed and torque was developed. To control the field flux via field current control in the WRSM, a general H-bridge circuit was added to the WRSM inverter to get the rapid current response in the high-speed region; the characteristics were compared with the chopper circuit. A WRSM developed for the belt-driven e-Assist system and a prototype 115 V power electronic converter to drive the WRSM were tested with a 900 cc combustion engine. The test results showed that the WRSM-type e-Assist system had good characteristics and could successfully start and assist the 900 cc combustion engine.

액체로켓엔진에서 충돌형 분사기 형태의 연료과잉 가스발생기 연소특성 (Combustion Characteristics of Fuel-rich Gas Generator with Impinging Injector for a Liquid Rocket Engine)

  • 한영민;김승한;이광진;문일윤;설우석;이창진
    • 한국항공우주학회지
    • /
    • 제33권6호
    • /
    • pp.64-70
    • /
    • 2005
  • 본 논문에서는 충돌형 분사기를 장착한 연료 과잉 가스발생기에서 수행한 설계점 및 탈설계점 연소시험의 전반적인 결과에 대하여 논하였다. 가스발생기는 충돌형 분사기와 추진제 공급 메니폴드로 구성된 분사기 헤드, 물냉각 채널을 가진 연소실, 혼합을 증가시키는 turbulence ring, 온도 및 압력을 측정하는 링, 그리고 노즐로 구성되었다. 여러 운영조건에서 연소시험은 성공적이었으며 가스발생기 손상은 발생하지 않았다. 체류시간 4~6msec 정도에는 출구온도변화가 거의 없었지만 압력변동에 따라 출구온도는 변하였다. 측정되는 압력, 유량 그리고 노즐목 크기로 계산한 연소효율는 출구에서 측정한 온도의 제곱근에 비례하는 관계식을 저 혼합비 가스발생기에서도 갖고 있었다. 가스발생기의 O/F 비 변화에 가장 민감하게 출구온도가 변화하였으며 이에 대한 관계식을 도출하여 향후 설계 기초 자료로 활용되게 하였다.

수냉각 발전기 고정자의 권선 내부 건조 판정 기준 설정에 관한 실험적 연구 (An Experimental Study on the Dryness Judgement Criterion for Water-cooled Generator Stator Windings)

  • 김희수;배용채;이욱륜;이두영
    • 대한기계학회논문집B
    • /
    • 제34권2호
    • /
    • pp.137-143
    • /
    • 2010
  • 발전기 고정자 권선 내부의 완전 건조는 누수시험을 위한 필요/충분조건이다. 발전기 운전에 의한 고주기 피로는 미세 균열 발생의 원인이 되고, 미세 균열에서의 물분자는 누설 진단의 신뢰성을 저하시킨다. 이와같은 이유로, 발전기 고정자 권선에 대한 누수시험에서 권선에 누설처가 있음에도 불구하고 누설이 없다는 결론과 같은 오류를 범하고 있다. 발전기 제작사는 누수시험을 고유한 건조 판정 기준을 제시하고 있지만, 실제로는 어떤 판정 기준도 누수시험을 위해 정확하게 건조 판정 기준을 지시하고 있지는 못하고 있는 실정이다. 그 이유는 발전기 고정자 권선의 복잡한 구조와 효과적인 건조 장비의 부재 때문이다. 본 논문에서는 수 냉각 발전기 고정자 권선의 내부 건조 여부를 판정하기 위한 건조 판정 기준을 완벽하게 제안하였으며 실험적으로 증명하였다.

일체형원자로의 신개념 안전계통 실증을 위한 실험적 연구 (Experimental Study on Design Verification of New Concept for Integral Reactor Safety System)

  • 정문기;최기용;박현식;조석;박춘경;이성재;송철화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2053-2058
    • /
    • 2004
  • The pressurized light water cooled, medium power (330 MWt) SMART (System-integrated Modular Advanced ReacTor) has been under development at KAERI for a dual purpose : seawater desalination and electricity generation. The SMART design verification phase was followed to conduct various separate effects tests and comprehensive integral effect tests. The high temperature / high pressure thermal-hydraulic test facility, VISTA(Experimental Verification by Integral Simulation of Transient and Accidents) has been constructed to simulate the SMART-P (the one fifth scaled pilot plant) by KAERI. Experimental tests have been performed to investigate the thermal-hydraulic dynamic characteristics of the primary and the secondary systems. Heat transfer characteristics and natural circulation performance of the PRHRS (Passive Residual Heat Removal System) of SMART-P were also investigated using the VISTA facility. The coolant flows steadily in the natural circulation loop which is composed of the steam generator (SG) primary side, the secondary system, and the PRHRS. The heat transfers through the PRHRS heat exchanger and ECT are sufficient enough to enable the natural circulation of the coolant.

  • PDF