• Title/Summary/Keyword: Water wall

Search Result 1,660, Processing Time 0.025 seconds

Mechanical and hydraulic interaction between braced wall and groundwater (흙막이 벽체와 그라우트 특성에 따른 구조.수리상호 작용)

  • Nam, Teak-Soo;Yoon, Jau-Ung;Kwon, Oh-Yeob;Shin, Jong-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1172-1177
    • /
    • 2010
  • For the deep excavation in urban area, the braced-cut method is mainly adopted. In this case, inadequate consideration of ground water level may result in wrong prediction of structural behavior. In this study, the effects of hydraulic interaction between wall and grout were investigated using the finite element method. The maximum stress in case of confined ground water condition is obtained at the final excavation stage in the range of 70~80% of excavation depth. The stress of impermeable case is about 50% larger than that of permeable case. When the relative permeabililty of wall-grout become smaller, the stress is getting bigger. And the stress tends to converge in case of 1/100 or less of the relative permeability.

  • PDF

The Cooling Performance of Thrust Chamber with Film Cooling (막냉각에 따른 추력실의 냉각 성능)

  • Kim, Sun-Jin;Jeong, Hae-Seung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.1 s.24
    • /
    • pp.117-124
    • /
    • 2006
  • Experiments on film cooling were performed with a small scale rocket engine homing liquid oxygen (LOx) and Jet A-1(jet engine fuel). Film coolants(Jet A-1 and water) were injected through the film cooling injector. Film cooled length and the outside wall temperature of the combustor were determined for chamber pressure, and the different geometries(injection angle) with the flow rates of film coolant. The loss of characteristic velocity due to film cooling was determined for the case of film cooling with water and Jet A-1. As the coolant flow increases, the outside wall temperatures decrease but the decrease in the outside wall temperatures reduced over the 8 percent film coolant flow rate. The efficiency of characteristic velocity was decreased with the Increase of the film coolant flow rate.

Wave Reflection of Perforated-Wall Caisson Breakwaters with Curtain-Wall (직립 유공케이슨 방파제의 현수판 사용에 따른 반사특성)

  • Lee, Seung Hyeob;Hwang, Jong Kil;Cho, Yong-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1454-1458
    • /
    • 2004
  • 본 인구에서는 직립 유공 케이슨에 현수판을 설치함으로서 입사파의 반사율을 저감시키고자 하였다. 먼저 케이슨 단면의 적정 유공율을 선정하기 위해 횡 SLIT 케이슨식 2개안 및 종 SLIT 1개안 단면에 대한 단면 실험을 실시하였다. 선행된 실험에서 가장 반사율이 낮은 SLIT 케이슨을 선택하여 유수실에 현수판을 설치 하였으며 현수판의 설치유무 및 현수판의 길이에 따른 반사계수를 검토하였다. 설치된 현수판은 장주기파에 대해서 반사율 저감효과를 얻을 수 없었지만 단주기 파에서는 반사율이 줄어드는 효과를 얻을 수 있었다. 해역에따라 단주기가 주류를 이루는 해역에서 현수판을 설치하면 파랑내습시 소파효과가 증대될 것으로 기대된다.

  • PDF

Reliability Analysis Method for Repeated UT Measurement Data in Nuclear Power Plants (원전 배관의 반복 측정 데이터에 대한 신뢰도 분석 방법)

  • Yun, Hun;Hwang, Kyeong-Mo
    • Corrosion Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.142-148
    • /
    • 2013
  • Safety is a major concern in Nuclear Power Plants (NPPs). Piping systems in NPPs are very complex and composed of many components such as tees, elbows, expanders and straight pipes. The high pressure and high temperature water flows inside piping components. As high speed water flows inside piping, the pipe wall thinning occurs in various reasons such as FAC (Flow Accelerated Corrosion), LDIE (Liquid Droplet Impingement Erosion) and Flashing. To inspect the wall thinning phenomenon and protect the piping from damages, piping components are checked by UT measurement in every overhaul. During every overhaul, approximately 200~300 components (40,000~60,000 UT data) are examined in NPPs. There are some methods from EPRI for evaluating wear rate of components. However, only few studies have been conducted to find out the raw data reliability for the wear rate evaluation. Securing the reliable raw data is the key factor for a reasonable evaluation. This paper suggests the reliability analysis method for the repeatedly measured data for wear rate evaluation.

Effect of Wall Proximity on Air Bubbles Rising in Liquid (액체중을 상승하는 공기포의 괸벽영향)

  • Kang, Joon Mo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • The purpose of this paper is to clarify the effect of wall proximity on the terminal velocity of single air bubbles in vertical tubes. As an initial step, experiments were conducted to determine the terminal velocity, shape, and path of single air bubbles rising freely in water. The terminal velocity of air bubbles rising through water was measured in cylindrical tubes, rectangular tubes, and parallel plates respectively. The results of effect wall of cylindrical tubes were shown as a dimensionless plot, and may also be used to arrive at a decision regarding the minimum size of tube.

Evaluation of the Functions and Reliability of an Eco-Friendly Vegetated Soundproof Wall for Climate Benefits

  • Jong-Sung Kim;Young-Hyoo Kwon;Yong-Jo Jung
    • Journal of Forest and Environmental Science
    • /
    • v.40 no.2
    • /
    • pp.141-150
    • /
    • 2024
  • This study aims to develop and commercialize a soundproof wall capable of planting at the urban ecological. The vegetative soundproof wall developed in the study showed highly superb structural test results for sound absorption coefficients and met the quality standards in the sound-absorbing performance test. Its structure is systemized to supply water to soils and plant roots inside the planting basis with rainwater running down the inclined planes near the planting basis in the front of the vegetation panel. It allows for sporadic water supply for about 30 days of drought. The test results show that the plants continued favorable growth and development in leaves, stems, and roots, making the vegetative soundproof plate a product capable of reacting to climate environment changes.

Turbulence Characteristics in a Circular Open Channel by PIV Measurements

  • Kim, Sun-Gu;Sung, Jae-Yong;Lee, Myeong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.7
    • /
    • pp.930-937
    • /
    • 2011
  • The characteristics of mean velocity and turbulence have been analyzed in the circular open channel flow using PIV measurement data for a wide range of water depth. The measured data are fitted to a velocity distribution function over the whole depth of the open channel. Reynolds shear stress and mean velocity in wall unit are compared with the analytic models for fully-developed turbulent boundary layer. Both the mean velocity and Reynolds shear stress have different distributions from the two-dimensional boundary layer flow when the water depth increases over 50% since the influence of the side wall penetrates more deeply into the free surface. The cross-stream Reynolds normal stress also has considerably different distribution in view of its peak value and decreasing rate in the outer region whether the water depth is higher than 50% or not.

Expression Characteristics of Chinese Cabbage

  • Kim, Y.J.;Oh, Y.T.;Lee, D.H.;Lee, Y.B.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1318-1328
    • /
    • 1993
  • Expression of chinese cabbage was conducted in order to investigate its dewatering behavior. Chipped cabbage was packed into cylinder and pressed by piston up to the predetermined pressure on Instron-1000. The rates of dewatering were affected domintantly by the applied pressure, but not significantly by the packed amount of cabbage in the cylinder. The pressure effect was increased very abruptly at first, but the increase rate was very low at high pressure greater than 20 MPa, showing great deviation from linear dependence of flow rate on pressure in Darcy's Law. Therefore, water expression from cabbage was not Newtonian flow of water through cell wall. In fact, the squeezed water contained a lot of solid particles, showing destruction of cell wall. The content of solid particles in expressed water was only slightly lower than the dry matter content of fresh chinese cabbage, determined by drying oven method.

  • PDF

Compression and Dewatering of Chinese Cabbage (배추의 압축탈수특성에 관한 연구)

  • Kim, Y.J.;Lee, D.H.;Lee, Y.B.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.1
    • /
    • pp.3-8
    • /
    • 1994
  • An experiment on the expression and dewatering of chinese cabbage was conducted in order to investigate its dewatering behavior. Chopped cabbage was packed into cylinder and pressed by piston upto the predetermined pressure on Instron-1000. The rates of dewatering were affected domintantly by the applied pressure, but not significantly by the packed amount of cabbage in the cylinder. The pressure effect was increased very abruptly at first, but the increase rate was very low at high pressure greater than 20 MPa, showing great deviation from linear dependence of flow rate on pressure in Darcy's Law. Therefore, water expression from cabbage was not Newtonian flow of water through cell wall. In fact, the squeezed water contained a lot of solid particles, about 3% of solid cabbage particles, showing destruction of cell wall. It appeared that compression and dewatering of vegetable wastes in the low pressure. under 20 MPa, is more desirable for later treatment of the dewater. More researches are needed in order to develop a treatment method for the solid particles in the expressed water before an expeller treatment system can be applied to vegetable wastes.

  • PDF

Absorption of Water Vapor into an Absorbing Binary Liquid Film Falling over a Horizontal Tube Bank (수평원관군상(水平圓管群上)의 이원흡수용액유동(二元吸收溶液流動)에 의(依)한 전달흡수특성(傳達吸收特性))

  • Kim, S.;Kim, Y.I.;Seo, S.C.;Hwang, D.K.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.583-589
    • /
    • 1988
  • Condensation of water vapor into an absorbent liquid of LiBr-water solution falling over a bank of water cooled horizontal tubes was investigated theoretically. The governing conservation equation for a re-defined physical transport phenomena were solved numerically using a finite difference method. Raw parameters were used in this study, since reliable experimental data is required prior to a dimensionless parametric study. The average values of wall heat transfer coefficient and interfacial absorption rate were defined to see the system performance. Other parameters include tube diameter, streamwise coordinate (and number of tubes in row), mass flow rate, and the wall temperature. The effects of these quantities on the absorption processes and suggestions for a rational system design have been presented.

  • PDF