The Cooling Performance of Thrust Chamber with Film Cooling

막냉각에 따른 추력실의 냉각 성능

  • Published : 2006.03.01

Abstract

Experiments on film cooling were performed with a small scale rocket engine homing liquid oxygen (LOx) and Jet A-1(jet engine fuel). Film coolants(Jet A-1 and water) were injected through the film cooling injector. Film cooled length and the outside wall temperature of the combustor were determined for chamber pressure, and the different geometries(injection angle) with the flow rates of film coolant. The loss of characteristic velocity due to film cooling was determined for the case of film cooling with water and Jet A-1. As the coolant flow increases, the outside wall temperatures decrease but the decrease in the outside wall temperatures reduced over the 8 percent film coolant flow rate. The efficiency of characteristic velocity was decreased with the Increase of the film coolant flow rate.

Keywords

References

  1. G. P. Sutton, 'Rocket Propulsion Element', 7th John Wiley & Sons Inc, 1992
  2. Dieter K. Huzel and David H. Huang, 'Modem Engineering for Design of Liquid-propellant Rocket Engines', AIAA, Vol. 147, Progress in Astronautics & Aeronautics, 1992
  3. G. P. Sutton, W. R. Wagner and J. D. Seader, 'Advanced Cooling Techniques for Rocket Engines', Astronautics & Aeronatics, January 1966
  4. 정해승, 최영환, 김유, 김선지, '액체로켓엔진의 막냉각에 관한 실험적 연구(I)', 한국항공우주학회지, 33권 6호, 2005, pp.71-75 https://doi.org/10.5139/JKSAS.2005.33.6.071
  5. M. B. цоъроBлъский, 'Жидкостнье ракет ньIе цвигателей', Изцательство <машиностроение>, 1968
  6. 유철성, 하성업, 조남경, 설우석, 'KSR-III 주엔진 연소시 냉각 특성', 한국추진공학회 추계학술발표회 논문집, 2000, pp.7
  7. H. Tamura, F. Ono, H. Gomi, 'High Pressure LOX/Heavy Hydrocarbon Fuel Rocket Combustor Investigation', 16th ISTS, 1988, pp.265-272