The Comparison Among Prediction Methods of Water Demand And Analysis of Data on Water Services Using Data Mining Techniques (데이터마이닝 기법을 활용한 상수 이용현황 분석 및 단기 물 수요예측 방법 비교)

  • Ahn, Jihoon;Kim, Jinhwa
    • The Journal of Bigdata
    • /
    • v.1 no.1
    • /
    • pp.9-17
    • /
    • 2016
  • This study identifies major features in water supply and introduces important factors in water services based on the information from data mining analysis of water quantity and water pressure measured from sensors. It also suggests more accurate methods using multiple regression analysis and neural network in predicting short term prediction of water demand in water service. A small block of a county is selected for the data collection and tests. There isa water demand on business such as public offices and hospitalstoo in this area. Real stream data from sensors in this area is collected. Among 2,728 data sets collected, 2,632 sets are used for modelling and 96 sets are used for testing. The shows that neural network is better than multiple regression analysis in their prediction performance.

  • PDF

Research on Advanced Measures for Emergency Response to Water Accidents based on Big-Data (빅데이터 기반 수도사고 위기대응 고도화 방안에 관한 연구)

  • Kim, Ho-sung;Kim, Jong-rip;Kim, Jae-jong;Yoon, Young-min;Kim, Dae-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.317-321
    • /
    • 2022
  • In response to Incheon tap water accident in 2019, the Ministry of Environment has created the "Comprehensive Measures for Water Safety Management" to improve water operation management, provide systematic technical support, and respond to accidents. Accordingly, K-water is making a smart water supply management system for the entire process of tap water. In order to advance the response to water accidents, it is essential to secure the reliability of real-time water operation data such as flow rate, pressure, and water level, and to develop and apply a warning algorithm in advance using big data analysis techniques. In this paper, various statistical techniques are applied using water supply operation data (flow, pressure, water level, etc) to prepare the foundation for the selection of the optimal operating range and advancement of the monitoring and alarm system. In addition, the arrival time is analyzed through cross-correlation analysis of changes in raw water turbidity between the water intake and water treatment plants. The purpose of this paper is to study the model that predicts the raw water turbidity of a water treatment plant by applying raw water turbidity data considering the time delay according to the flow rate change.

  • PDF

An analysis of time series models for toilet and laundry water-uses (변기 및 세탁기 가정용수 사용량의 시계열모형 연구)

  • Myoung, Sungmin;Kim, Donggeon;Lee, Doo-Jin;Kim, Hwa Soo;Jo, Jinnam
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.6
    • /
    • pp.1141-1148
    • /
    • 2013
  • End-uses of household water have been influenced by a housing type, life style and housing area which are considered as internal factors. Also, there are external factors such as water rate, weather and water supply facilities. Analysis of influential factors on water consumption in households would give an explanation on the cause of changing trends and would help predicting the water demand of end-use in household. In this paper, we used real data to predict toilet and laundry water-uses and utilized the linear regression model with autoregressive errors. The results showed that the monthly autoregressive error models explained about 71% for describing the water demand of end-use in toilet and laundry water-uses.

Establishment of AI-based composite sensor pre-verification system for energy management and composite sensor verification in water purification plant (정수장에서의 에너지 관리 및 복합센서 검증을 위한 AI 기반 복합센서 사전검증시스템 구축)

  • Kim, Kuk-Il;Sung, Min-Seok;An, Sang-Byung;Hong, Sung-Taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.43-46
    • /
    • 2022
  • The optimal operation of the water purification plant can be carried out only when the required flow rate is supplied in a timely manner using the minimum electrical energy by accurately predicting the pattern and amount of tap water used in the consumer. In order to ensure the stability of tap water production and supply, a system that can be pre-verified before applying AI-based composite sensors to the water purification plant was established to derive complementary matters through the pre-verification model for each composite sensor and improve the quality and operation stability of the composite sensor data.

  • PDF

Development of a water meter freeze test device for predicting the freezing time based on AI (AI 기반 동파시기 예측을 위한 수도계량기 동파시험장치 개발)

  • Kim, Kuk-il;An, Sang-byung;Kim, Jin-hoon;Hong, Sung-taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.233-234
    • /
    • 2021
  • The freezing of the water meter due to the cold wave in winter causes safety accidents caused by freezing and suspending the supply of tap water and various inconveniences. In this study, the water meter develops a test device similar to the environment in which the actual freezing occurs and tests repeatedly by changing the temperature, humidity, flow rate, pressure, valve improvement, pump operation status, etc. Based on the data obtained through this, it is planning to predict the timing of freezing by applying AI technology to correlation between freeze influencing factors.

  • PDF

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.

Development of a GIS-Based Basin Water Balance Analysis Model (GIS 기반의 유역물수지 분석모형 개발)

  • Hwang, Eui-Ho;Kim, Kye-Hyun;Park, Jin-Hyeog;Lee, Geun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.4
    • /
    • pp.34-45
    • /
    • 2004
  • Existing Semangeum's water balance analysis simplifies whole basin to single basin and achieved volume of effluence that produce by Kajiyama way to foundation. But Semangeum is complicated and various rice-wine strainer supply system. And there is difficulty to apply as elastic when water balance element is changed at free point. Divided to unit possession station for suitable water balance analysis model application to Semangeum in this study. And developed basin water balance model of GIS base that can do details analysis is bite about development and transfer of an appropriation in the budget of basin water resources. Achieved study including abstraction and concept design that use UML (unified modeling language) diagram for details analysis, stream network composition for rice-wine strainer supply system application, preprocessing of GIS base and postprocessing module development, model revision and verification etc. Support of this water balance analysis model is available to establish efficient water resources administration plan through outward flow process analysis of water resources. And support is considered to be possible in more convenient and, reasonable water resources administration way establishment by minimizing manual processing in systematic water resources government official to user and support diversified analysis system.

  • PDF

The Use of geographic information system for planning rural water rescources systems (농어촌지역의 수자원시스템 계획을 위한 지리정보 시스템의 활용)

  • 정하우;이정재;이남호;김성준;최진용
    • Spatial Information Research
    • /
    • v.3 no.1
    • /
    • pp.39-46
    • /
    • 1995
  • Rural water resources systems may be largely constituted by two parts. One is rural water supply systems such as reservoirs, wells, pumping stations. The other is rural water demand systems which include municipal water, irrigation water, industrial water, livestocks water, inland fisheries water and envir¬onmental water in rural areas. planning to develop rural water resources systems is a very hard task because of their complicated factors and the large number of spatial data to investigate and manipulate. A Geographic Information SystemCGIS) will be a powerful and efficient tool to handle the spatial data and to plan the land use. All data can be efficiently maintained and easily updated. This paper refers to the construction of a GIS for planning rural water resources systems applied to Kokseong County, Cheonnam Province, Republic of Korea. The Geographic Informa¬tion was constituted by 4 layers of base map and 11 layers of thematic map.

  • PDF

An Experimental Study on the Part-Load Performance of a River Water Source 2-Stage Heat Pump (하천수 열원 2단 압축 열펌프시스템의 부분부하 운전특성에 관한 실험적 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Ra, Ho-Sang
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1964-1968
    • /
    • 2007
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. Although its better performance, the large temperature difference between load and source makes system performance worse by nature. In this study, 2-stage compression is considered as the solution of this problem. Generally, heat pump is designed for maximum capacity rate, but it actually operates at part load condition in many cases. Therefore, an information on the part-load character is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes. The experimental results show that the system performance is influenced by the part load rates, river water temperature, load temperature, etc.

  • PDF

A study on the part-load performance of 2-stage water source heat pump (2단 압축 수열원 열펌프 시스템의 부분부하 운전특성에 관한 연구)

  • Lee, Young-Soo;Baik, Young-Jin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2009
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. In this study, an experimental study on a 2-stage heat pump, which is designed to utilize a river water heat source, were carried out. Generally, a heat pump is designed for maximum capacity rate, but it actually operates at part load condition in most cases. Therefore, an information on the part-load characteristic is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes.

  • PDF