• Title/Summary/Keyword: Water supply and demand

Search Result 405, Processing Time 0.024 seconds

Flow duration change in downstream of reservoir by selective deficit supply method (선택적 부족분 공급방식에 따른 댐 하류하천의 유황 변화 분석)

  • Choi, Youngje;Park, Moonhyung
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.12
    • /
    • pp.1021-1030
    • /
    • 2022
  • Currently, South Korea implements water resources management policies focusing on integrated water quantity, quality and hydro-ecology management. In particular, rehabilitation of natural rivers has become a major issue. As for reservoir operation during non-flood season, efforts have been made continuously to apply the Deficit Supply Method that can maximize water supply to address droughts and increase in water demand. When Deficit Supply Method is applied, the water supply capacity of reservoir can be maximized. However, downstream water flow would remain constant. In consideration that a natural stream, a long-time-created hydro-ecology, can be significantly influenced by flow variability, the Deficit Supply Method-based reservoir operation can generate effective water supply. Still, it may trigger adverse effects from the aspects of natural rehabilitation and hydro-ecology recovery. The main objective of this study is to analyze impacts on downstream flow duration through reservoir simulation by comparing the Firm Supply Method, the Deficit Supply Method and the Selective Deficit Supply Method, and examining each method's effects on reservoir operation. This study found that the Firm Supply Method could maintain water flow variability, but could not maximize water supply capacity. When the Deficit Supply Method was applied, water supply capacity could be increased while remaining vulnerable regarding water flow variability, as a difference between average flow and low flow was negligible at downstream. In comparison, the Selective Deficit Supply Method was found to sustain time-based reliability at 95% or higher, whereas downstream flow duration could be maintained at a level similar to the level generated by the Firm Supply Method.

Development of Optimal Reservoir System Operation Model for Water Supply by Applying MIP Technique and Reappraisal of Water Supply Capability of Nakdong River Basin (MIP에 의한 댐군연계운영 최적화모형 개발과 개발 모형에 의한 낙동강수계 용수공급능력 재평가)

  • Choe, Yeong-Song;An, Gyeong-Su;Park, Myeong-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.4
    • /
    • pp.447-459
    • /
    • 2000
  • Since the development of water resources is getting more difficult than ever before because of human-sociological condition, it would be necessary to develop a practically applicable technique for the management of water resources based on demand-side concept that could reduce unusable release for more effective and appropriate allocation of limited water resources. The objective of the study is to develop an optimal reservoir system operation model for water supply and energy augmentation by the combination of water budget analysis method in downstream area by MIP technique. The applicable study of the developed model was carried out and water supply capability of Nakdong river basin was re-evaluated by the developed model. The model has been found successful to guarantee appropriate water supply to the basin by means of deficit-supply management method and also turned out to be more practical tool for an optimal reservoir system operation model than other existing models.

  • PDF

Design of Micro Water Supply System Using Solar Energy

  • Sharma, Ekisha;Khatiwada, Nawa Raj;Ghimire, Anish
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.8-17
    • /
    • 2019
  • Solar pumps, for water lift systems, is becoming popular in rural areas for supplying drinking water in dry seasons when its need is elevated. The development in technology has also made solar pumps readily available and cheap which has increased its demands. So, for scattered settlements having a limited budget for operation and maintenance costs, solar pump is preferred over grid connected electrical pumping systems. This primary objective of the study was to design a solar photovoltaic pumping drinking water supply system for a small health post which is about 45 km east from Kathmandu, the capital city of Nepal. The study also compared and verified the final design with the system's existing design prepared by a development agency. The water source for this study was a confined aquifer 115m below the surface. The water demand was calculated to be 11m3 per day. A 1500 kPa submersible pump attached to a motor was selected and installed. Along with that twelve solar panels, reservoir, transmission main and distribution main was designed. The outcomes conclude solar photovoltaic pumping water supply systems to be cost-effective with an estimated cost of only USD 0.84 million per MLD. Solar pumps require low maintenance and operation costs and its repairs can quickly be done by the local people. The study also shows that solar technology produces no sound, needs no fuel making it environmentally friendly.

A Study on the Prediction of Daily Urban Water Demand with Multiple Regression Model (회귀모형에 의한 상수도 1일 급수량 예측에 관한 연구)

  • 박성천;문병석;오창주;이병조
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.1
    • /
    • pp.68-77
    • /
    • 1998
  • The purpose of this paper is to establish a method estimating the daily urban water demand using statistical analysis that is used for developing the efficient management and operation of the water supply facilities, and accurary of the model is verified by error rate and F-value. The data used in this study were the daily urban water use, the weather conditions such as temperature, precipitation, relative humidity, etc, and the day of The week. The case study was taken placed for the city of Namwon in Korea. The raw data used in this study were rearranged either by month or by season for analysis purpose, and the statistical analysis was applied to the data to obtain the regression model As a result of this study, the linear regression model was developed to estimate the daily urban water use with weather condition. The regression constant and coefficients of the model were determined for each month of a year. The accuracy of the model was within 3% of average error and within 11% of maximum error. The resulting model was found to he useful to the practical operation and management of the water supply facilities.

  • PDF

A study on operation and management for TOC removal of public sewage treatment works (하수처리시설에서 총유기탄소(TOC) 처리를 위한 운영·관리 고찰)

  • Jeong, Dong-Hwan;Chung, Hyenmi;Cho, Yangseok;Kim, Eunseok;Kim, Changsoo;Park, Junwon;Lee, Wonseok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.535-550
    • /
    • 2018
  • Total organic carbon (TOC) will replace chemical oxygen demand ($COD_{Mn}$) as an effluent water quality standard in public sewage treatment works (PSTWs) from 2021 in Korea. To ensure effective control of TOC in the effluent, investigation was carried out into TOC levels and sewage treatment operation factors in five target PSTWs using anaerobic-anoxic-aerobic ($A_2O$) processes, media, membrane, and sequencing batch reactor (SBR) technologies. TOC removal efficiencies appeared to be 93-96% on average. As a fraction of TOC, biodegradable dissolved organic carbon (BDOC) was reduced from 64% in the influent to 9% in the effluent in these PSTWs. During the investigation, biological treatment processes were applied flexibly for operation factors such as HRT, SRT, MLSS, F/M ratios and BOD volume loads, based on the influent characteristics and design conditions. As a result, we suggest efficient operating conditions in PSTWs by evaluating relationships between TOC removal and operation factors.

Estimation on an Amount of the Groundwater Demand and Supply for Applying the Well-network System (WNS) to a Frequent-drought Area (관정연계이용 기술 적용을 위한 상습가뭄지역 지하수 수요-공급량 평가)

  • Lee, Byung Sun;Jeong, Chanduck;Lee, Gyusang;Ha, Kyoochul;Lee, Jong-Hwa;Song, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.2
    • /
    • pp.24-35
    • /
    • 2022
  • This study was conducted to estimate groundwater demand and supply for agricultural activities in a frequent-drought area that requires implementation of optimal distribution plan utilizing the well-network system (WNS). The WNS has been considered as a viable strategic way of supplying groundwater to farmlands by connecting groundwater wells physically or virtually. The study area heavily relied on groundwater resources for irrigation up to 53% due to a lack of surface water resources. Two kinds of methods, HOMWRS software and FAO approach, were used for estimating irrigation water requirements for paddy and upland fields, respectively. During the latest 10 years (2010~2019), the water requirements was estimated to be 1,106 m3/day. The requirements notably increased to 1,121~4,004 m3/day during active farming season (May to September), which exceeded the total yield capacity of pre-existing groundwater wells (2,356 m3/day) in the area. Detailed and definite determination for groundwater demand and supply helped to determine optimal scale parameters of WNS. The WNS has achieved more balanced distribution of groundwater resources for irrigation over the study area.

The Analysis on the Correlationship for Rousing Demands and Water Supply Ratio (주택수요 예측을 위한 주택량과 상수도보급률의 상관성 분석)

  • Yang Seung-Won;Park Keun-Joon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.2 s.24
    • /
    • pp.61-68
    • /
    • 2005
  • The analysis described in this paper indicate the existence of a correlationship for housing demand and water supply ratio. Using subjective statistical data for the trend of population on regional area, water supply ratio and the number of households, the paper examines the correlationship of forecasting factors for apartments in the ways in which the tendency of demands for apartments and water supply ratio have been analyzed within small and mediumsized city. Differences in the correlationship on the several scale of a city are also taken into account in the analysis. The summary table of the tendency for housing supplies, population and water supply ratio on each scale of a city was generated using data from LAIB. This study attempted to address certain factors that are measurable within a specified paradigm, in order to investigate the extent to which the expectation of apartment supplies can be estimated from the correlationship of water supply ratio. Therefore, it can be suggested that the limited scale of a city are set to maintain the correlationship for housing demands and water supply ratio.

Development of the method for optimal water supply pump operation considering disinfection performance (소독능을 고려한 송수펌프 최적운영기법 개발)

  • Hyung, Jinseok;Kim, Kibum;Seo, Jeewon;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.

Stochastic Reservoir Model for the Estimation of Optimal Water Supply (적정 용수 공급량 산정를 위한 추계학적 저수용량 모델)

  • 장인수;박정규;유일준
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.1
    • /
    • pp.29-38
    • /
    • 1995
  • The purpose of this study is to improve the present methodology-for the estimation of optimal water supply from an impounding reservoir. The stochastic reservoir storage model presented in this paper is believed to be rational in that. the probability of reservoir depletion (return period) is to be calculated for the various monthly demands and storage capacities. The monthly flows are used to derive the reservoir storage capacity-monthly demand-probability curves at Dalcheon damsite and Hongcheon damsite in Han river basin.

  • PDF

A study on pollutants removal characteristics of domestic riverbed filtration and riverbank filtration intake facilities (국내 복류수 및 강변여과수 취수시설의 오염물질 제거특성에 관한 연구)

  • Chan-woo Jeong;Sun-ick Lee;Sung-woo Shin;Chang-hyun Song;Bu-geun Jo;Jae-won Choi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.281-288
    • /
    • 2023
  • This study was performed to evaluate the pollutants removal characteristics of two types of RBFs(Riverbank filtration, Riverbed filtration) intake facilities installed in Nakdong River and in Hwang River respectively. The capacity of each RBF is 45,000 m3/d for riverbank filtration intake facility and 3,500 m3/d for riverbed filtration intake facility. According to data collected in the riverbank filtration site, removal rate of each pollutant was about BOD(Biochemical Oxygen Demand) 52%, TOC(Total Organic Carbon) 57%, SS(Suspended Solids) 44%, Total coliforms 99% correspondingly. Furthermore, Microcystins(-LR,-YR,-RR) were not found in riverbank filtered water compared to surface water in Nakdong River. DOC(Dissolved Organic Carbon) and Humics which are precursors of disinfection byproduct were also reported to be removed about 59% for DOC, 65% for Humics. Based on data analysis in riverbed filtration site in Hwang River, removal rate of each contaminant reaches to BOD 33.3%, TOC 38.5%, SS 38.9%, DOC 22.2%, UV254 21.2%, Total coliforms 73.8% respectively. Additionally, microplastics were also inspected that there was no obvious removal rate in riverbed filtered water compared to surface water in Hwang River.