• Title/Summary/Keyword: Water quality problems

Search Result 665, Processing Time 0.025 seconds

Effect of Seed Pretreatment with Chilling, $GA_3$ and Light on Bupleurum falcatum Germination (파종 전 저온, $GA_3$ 및 광 처리가 시호의 발아에 미치는 영향)

  • 강진호;김동일;류옥경;김은실;김영광
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.4
    • /
    • pp.384-391
    • /
    • 1997
  • In the cultivation of Bupleurum falcatum, one of the problems to surmount is long-term germination period and unstable germination. This experiment was done to examine the effect of $GA_3$ concentration [0(water), 0.01, 0.lmM], chilling, their treatment period [2, 4, 8 days ($GA_3$) : 0, 2, 4 weeks (chilling)] and light quality (red, white, dark) given during the period as pretreatment before sowing on the seed germination of its two cultivars (cv. Jaerae, cv. Jangsu). Light treatment was given during all the periods of $GA_3$ treatment or for 0, 2, 4 days at the end of the chilling treatment. There was no difference in the mean germination rate between the levels of all the treatments except the $GA_3$ concentration meaning that water imbibition and $GA_3$ treatment had the same effect. As light quality treatment during the water imbibition was forced, the mean germination rate of Jaerae, 2 to 4 days imbibition period or red light was more increased or accelerated compared to the other levels of the same treatment, respectively. The rate of Jaerae not affected by the light quality was the greatest in the 2 days water imbibition while the rate of Jangsu was the greatest when water-imbibed for 4 days or treated by red light. No chilling before sowing showed the highest rate due to the light quality and white light forced after sowing had greater rate than the dark treatment. Although there was no difference between the rates of light quality treatment levels in the condition of no chilling before sowing and white light treatment after sowing, the rate of Jangsu was enhanced or accelerated only under illumination during 2 days water imbibition before sowing.

  • PDF

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

Using Artificial Neural Networks for Forecasting Algae Counts in a Surface Water System

  • Coppola, Emery A. Jr.;Jacinto, Adorable B.;Atherholt, Tom;Poulton, Mary;Pasquarello, Linda;Szidarvoszky, Ferenc;Lohbauer, Scott
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Algal blooms in potable water supplies are becoming an increasingly prevalent and serious water quality problem around the world. In addition to precipitating taste and odor problems, blooms damage the environment, and some classes like cyanobacteria (blue-green algae) release toxins that can threaten human health, even causing death. There is a recognized need in the water industry for models that can accurately forecast in real-time algal bloom events for planning and mitigation purposes. In this study, using data for an interconnected system of rivers and reservoirs operated by a New Jersey water utility, various ANN models, including both discrete prediction and classification models, were developed and tested for forecasting counts of three different algal classes for one-week and two-weeks ahead periods. Predictor model inputs included physical, meteorological, chemical, and biological variables, and two different temporal schemes for processing inputs relative to the prediction event were used. Despite relatively limited historical data, the discrete prediction ANN models generally performed well during validation, achieving relatively high correlation coefficients, and often predicting the formation and dissipation of high algae count periods. The ANN classification models also performed well, with average classification percentages averaging 94 percent accuracy. Despite relatively limited data events, this study demonstrates that with adequate data collection, both in terms of the number of historical events and availability of important predictor variables, ANNs can provide accurate real-time forecasts of algal population counts, as well as foster increased understanding of important cause and effect relationships, which can be used to both improve monitoring programs and forecasting efforts.

Integrated Approach for Watershed Management in an Urban Area (도시 유역 관리를 위한 통합적인 접근방법)

  • Lee, Kil-Seong;Chung, Eun-Sung;Kim, Young-Oh
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.2 s.163
    • /
    • pp.161-178
    • /
    • 2006
  • Heathcote (1998) identified a systematic, seven-step approach to general watershed planning and management. It consists of 1) understanding watershed components and processes, 2) identifying and ranking problems to be solved, 3) setting clear and specific goals, 4) developing a list of management options, 5) eliminating infeasible options 6) testing the effectiveness of remaining feasible options, and 7) developing the final options. In this study the first five steps of that process were applied to the Anyangcheon watershed in Korea, which experiences streamflow depletion, frequent flood damages, and poor water quality typical of highly urbanized watersheds. This study employed four indices: Potential Flood Damage(PFD), Potential Streamflow Depletion(PSD), Potential Water Quality Deterioration(PWQD) and Watershed Evaluation Index(WEI) to identify and quantify problems within the watershed. WEI is the integration index of the others. Composite programming which is a method of multi-criteria decision making is applied for the calculation of PSD, PWQD and WEI (Step 2). The primary goal of the study is to secure instreamflow in the Anyangcheon during dry seasons. The second management goals of flood damage mitigation and water quality enhancement are also set (Step 3). Management options include not only structural measures that can alter the existing conditions, but also nonstructural measures that rely on changes in human behavior or management practices (Step 4). Certain management options which are not technically, economically, and environmentally feasible, are eliminated (Step S). Therefore, this study addresses a Pre-feasibility study, which established a master plan using Steps 1 through 5.

A Study on the Runoff Characteristics and Water Quality Management of Seung-Gi Stream Area (승기천 유역의 오염물 유출특성 및 수질관리방안 연구)

  • Seo, Hyung-Joon;Chung, Sang-Won;Park, Mi-Ok;Lee, Byung-Ryul
    • Clean Technology
    • /
    • v.7 no.4
    • /
    • pp.251-263
    • /
    • 2001
  • This study was conducted to provide a basic information for recovery plan of Seung-Gi Stream which is a major stream of Incheon metropolitan area. Source and characteristics of pollutants were analyzed and studied. Samples were taken 10 rounds in 5 sections in Seung-Gi stream. Annual pollutants loads and sectional characteristics of pollutants loads were investigated regarding flow rate, pH, DO, SS, $BOD_5$, $COD_{Cr}$, T-P, TKN and concentrations of Zn, Cd, Cu, Cr atoms which enter into Seung-Gi stream during rainy and dry season respectively. As one came close to the Nam-Dong Industrial Complex, sectional discharge loads were heavy and water quality was failed to meet the standard by "Environmental Standard of River Quality". As a result, heavy load of pollutants in Seung-Gi stream was considered to influence negatively the sea water quality of Incheon. Solution plans to solve problems are as follows. First, circulation of treated water at Seung-Gi WWTP(Wastewater Treatment Plant) and retreated water by URC(ultra rapid coagulation) process treat with that. Second, sewage and wastewater is gathered, make it disposed. After then, we circulate treated water. If solution plans be applied, we can predict water quality. Then we could grope for how make to recovery role of Seung-Gi stream as stream.

  • PDF

Feasibility study on district heating Magok area by sewage water heat source (마곡지구 하수열에너지이용 타당성 검토)

  • Lee, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.357-362
    • /
    • 2009
  • As a unutilized energy, treated sewage water locates widespread near urban areas. From the previous survey, the sewage water is reported to hold energy potential up to 36,000 Tcal/year, which was 2.1% of the total domestic energy consumption and 9.7% of the energy usage in the household and business sector in 2006. Temperature of the sewage water differs locally, but its range is observed in a range of $20{\sim}25^{\circ}C$ in summer and $8{\sim}13^{\circ}C$ in winter. Since the temperature range of the sewage water has a better seasonal distribution about $5{\sim}10^{\circ}C$ compared to ambient air, it is a promising heat sink for summer or heat source for winter. The sewage water is also a high quality heat source from its abundant quantity and uniform temperature. Considering the ambient temperature of Korea is very low in winter, a heat pump system using the sewage water can be an alternative to prevent problems of capacity deficiency and frost formation.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content of High Strength Concrete by Frequency Domain Reflectometry Sensor (고주파수분센서를 통한 고강도 콘크리트 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.173-174
    • /
    • 2023
  • In this study, unit-water content was measured using a frequency domain reflecometry(FDR) sensor that complements the problems of the existing unit-water content measurement method to evaluate the unit-water content affecting the workability, durability, and quality of high strength concrete. The experiment used the unit-water content of high strength concrete as a variable, and the accuracy and probability distribution of the unit-water content measured through deep learning were analyzed for the output value output through the FDR sensor. In the case of the unit-water content predicted by deep learning analysis, a high accuracy and high distribution of more than 93% were found within the error range of ± 10 kg/m3. In the future, research is needed to secure high reliability by utilizing data obtained through experiments with various variables.

  • PDF

The Quality Control of Mass Concrete mixed with Fly-Asy (플라이애쉬를 혼합한 매스콘크리트의 품질관리)

  • 박칠림;권영호;이상수;김동석;박상준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.940-945
    • /
    • 1998
  • Recently, serious cracking problems have been reported in this country while the process of actual massive concrete construction. he hydration heat arising from the chemical reaction of cement with water causes temperature differentials in between inside and outside of a structural member, and these temperature differentials induce thermal stresses. In this paper, we described on the practical application and quality control of the mass concrete mixed with fly-ash. This project is investigating adiabatic temperature rise test of concrete, mock-up test in the laboratory, ad B/P before placing the mass concrete in site. As a result, we can be prevent temperature cracking from the cement hydration heat of mass concrete and also can be showed up secure quality control flow chart of mass concrete.

  • PDF

Techniques for Characterizing Surface Deterioration of Epoxy Exposed to Ozone Damage (오존에 노출된 에폭시 코팅재의 표면 열화특성 평가기술)

  • Choi, Sung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.167-177
    • /
    • 2014
  • New technologies for water purification are continuously emerging to address global water quality problems, and one such technology involves advanced hermetic water purification facilities made by concrete that utilize ozone treatment processes. Better knowledge about surface deterioration of epoxy coating exposed to ozone treatment is needed as a foundation for development of improved methods and materials in the future. This study utilized atomic force microscopy (AFM), nanoindentation methods, and existing indirect methods such as visual observation, changes in mass, surface observation and chrominance analysis, to evaluate epoxy water-resistance and anti-corrosiveness. This study considered six different epoxy formulations to assess typical degradation characteristics of epoxy surfaces with regard to water-resistance/anti-corrosiveness. AFM and nanoindentation techniques emerged as promising direct methods with potential to provide quantitative measures of surface quality that are improvements upon existing indirect methods. The experiments also confirmed that some of the epoxy-coatings were severely iMPacted by ozone exposure, and thus the results demonstrate that concern about such deterioration is justified.

A Study on the high-flux MBR system using PTFE flat membrane and coagulant(Alum) for removal of phosphorus (PTFE재질의 평판형 분리막과 인제거를 위해 Alum주입을 적용한 고플럭스 MBR시스템에 관한 연구)

  • Lee, Eui-Jong;Kim, Kwan-Yeop;Kwon, Jin-Sub;Kim, Young-Hoon;Lee, Yong-Soo;Lee, Chang-Ha;Jeon, Min-Jung;Kim, Hyung-Soo;Kim, Jung-Rae;Jung, Jin-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.95-106
    • /
    • 2011
  • Even though MBR processes have many advantages such as high quality effluents, a small footprint and convenience for operation compared to conventional activated sludge processes, there are some shortcomings in terms of the cost and potential fouling incident that keeps MBR (Membrane bioreactor) processes from being widely applied. To reduce these problems, PTFE (Polytetrafluoroethylene) flat sheet membranes that have excellent permeability and durability were tested instead of PVDF (Polyvinylidene fluoride) membrane which is being used widely in water treatment. Low concentration of sodium hydroxide (NaOH) was also added into the membrane modules in order to prevent the membrane fouling as well as to provide the alkalinity. With conditions mentioned above, a pilot-scale MBR system based on the MLE (Modified Ludzack Ettinger) process was operated at flux of 40 $L/m^{2}/hr$ and over 15,000 mg/L MLSS concentration for about 8 months. And coagulant(alum) was added into the membrane tank to remove phosphorus. Although the more coagulant is added the more effectively phosphorus is removed, that can lead to fouling for a long operation(Ronseca et al.,2009). By the way there is a research that fouling grow up after stopping injection of coagulant(Holbrook, 2004). Stable operation of MBR systems was achieved without major chemical cleaning and the effluent quality was found to be good enough to comply with the treated waste water quality regulations of the Korea.