• Title/Summary/Keyword: Water purification plant

Search Result 208, Processing Time 0.036 seconds

Formation of Assimilable Organic Carbon from Algogenic Organic Matter

  • Kim, Ji-Hoon;Chung, Soon-Hyung;Lee, Jing-Yeon;Kim, In-Hwan;Lee, Tae-Ho;Kim, Young-Ju
    • Environmental Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • The objective of this study was to assess the variation in the concentration of assimilable organic carbon (AOC) in a drinking water resource, and investigate the characteristics of AOC derived from algae. The seasonal change in AOC at the Kamafusa dam corresponded to changes in the algal cell number. In order to understand the relationship between AOC and algae in a water resource and water purification plant, two kinds of laboratory experiment were performed. The algal culture experiment showed that extracellular organic matter (EOM) that was released during the growth of Phormidium tenue with M-11 medium led to significant increases in the AOC concentration, but no significant variation in the AOC concentration was observed with CT medium containing a high dissolved organic carbon concentration. The chlorination experiment showed that the AOC included in EOM was not easily removed by chlorination, although the AOC included in intercellular organic matter released from the algal cells by chlorination was removed under conditions where residual chlorine was detected.

A Microbiological Study on the Tap Water in Seoul (서울시 수도수 중의 위생물학적 조사연구)

  • 조영채
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.33-41
    • /
    • 1981
  • This study was carried out to investigate Water Temperature, Residual Chlorine, Coliform Groups, and the Standard Plate Counts of Water Supply Areas provided by 7 Water Purification Plant (W.P.P) in Seoul from September 20, 1979 through October 20, 1979. The results were summarized below: 1) The mean water temperature of the 63 Water Samples was 19.8$\circ$C, the mean pH 7.18, and the mean residual chlorine concentration 0.52 ppm by each Water Supply Areas. There is no statistically significant differences between the WPP Areas, but there is significant differences between water supply areas. 2) 30(47.6%) out of the 63 Water Samples were Standard Plate Counts free and 33 Samples (52.4%) were contaminated by Standard Plate Counts. 30 (47.6%) out of 33 samples showed the existence of Standard Plate Counts less than 15 and the other 3 samples 15-30. 3) 2 (3.2%) out of the 63 Samples had the coliform. Those 2 Samples had 2 and 6 coliform group counts per 50ml respectively both of them were 0.1ppm in residual chlorine. 4) There is correlation among Water Temperature, pH, Residual Chlorine, Standard Plate Counts, and Coliform Groups. The Coefficient of Correlation(r) between Water Temperature & Residual Chlorine was 0.147, 0.240 between Water Temperature & Standard plate Counts and 0.215 between pH & Standard Plate Counts. These correlations are statistically no significant, But the correlation of coefficient between pH & Residual Chlorine was -0.291 which is showed significant correlation at p<0.05. The coefficient of correlation between Residual Chlorine & Standard Plate Counts was -0.441 which is showed Negative Correlation Statistically Significant difference at p<0.01.

  • PDF

Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-gu, Daegu City (대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가)

  • Lee, Myeong-Sug;Keum, Jong-Lok;Kang, Dong-Hoon;Jo, Hang-Wook;Kwon, Byoung-Youne;Kim, Eun-Deok;Lee, Chan-Hyung;Song, Hee-Bong;Shin, Sang-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.45-54
    • /
    • 2021
  • Objectives: This study evaluated the odor around an industrial complex area (#1-#5) and the operational effects of the Odor Monitoring System in Seo-gu in Daegu City. Methods: Samples were collected from November 2012 to December 2018 and were analyzed for complex odor. The odor occurrence rate and the odor reduction rate were calculated. Results: In 2018, the mean concentration of complex odor decreased 20.9% and the odor occurrence rate decreased from 65.0 to 27.5% around the industrial complex area (#1-#5) in Seo-gu compared to 2013. After the operation of the Odor Monitoring System, the standard excess rate (3.0%→40.8%) and the excess concentration of complex odor (1,442→4,304) increased at odor-emitting workplaces. In addition, the mean concentration of complex odor (15.9%) and the odor occurrence rate (60.6%→32.9%) around the industrial complex area (#1-#5) and the number of odor complaints (23.4%) in Seo-gu decreased. Conclusion: In order to reduce the odor around the industrial complex area, it is important to improve the odor emitting facilities. The Odor Monitoring System uses scientific and systematic monitoring methods that can help control and manage the odor emission facilities.

Element Technology and Strategy of Digital Twin in the Water Treatment (수처리공정의 디지털 트윈 요소기술과 추진 전략)

  • Young-Man Cho;Yong-Jun Jung
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.284-290
    • /
    • 2023
  • Domestic water supply and sewage facilities are rapidly aging and maintenance difficulties such as aging of operation and management personnel are overlapping, so Digital Twin technology is attracting attention as an intelligent means of process management. Digital twin projects for domestic water treatment processes include the smart sewage treatment project promoted by the Ministry of Environment, projects independently promoted by some local governments, and digital twin purification plant projects promoted by K-water. However, the content of digital twin promotion is different for each institution. Therefore, in the water treatment process, technological standardization and step-by-step implementation methods for digital twins must be preceded to reduce trial and error in future business promotion. This study aims to provide an efficient promotion plan by prescribing the digital twin element technology and composition method in the water treatment process and reviewing the contents currently being promoted by the Ministry of Environment, local governments, and K-Water individually.

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus in Livestock Treatment System Using Constructed Wetlands (인공습지 축산폐수처리시스템에서 질소 및 인 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Jong-Hwan;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tea;Jeong, Tae-Uk;Choi, Jeong-Ho;Lee, Sang-Won;Kim, Hyun-Ook;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.434-441
    • /
    • 2011
  • To improve T-N and T-P removal efficiencies, removal efficiencies of pollutants in full-scale livestock wastewater treatment plant by natural purification method with water plant filtration and activated sludge beds were investigated under different re-injection rates and injection methods of livestock wastewater. The removal rates of COD, SS, T-N, and T-P in effluent in full-scale livestock wastewater treatment plant were in the order of 30% < 70% ${\leq}$ 100 % at different re-injection rates. The removal rates of pollutants in effluent in full-scale livestock wastewater treatment plant were higher as re-injection rate of livestock wastewater increased. Removal rates of COD, SS, T-N, and T-P by continuous injection were slightly higher than those by intermittent injection method in full-scale livestock wastewater treatment plant. Removal rates of COD, SS, T-N, and T-P by continuous injection method in full-scale livestock wastewater treatment plant with water plant filtration and activated sludge beds were 99.5, 99.8, 99.0 and 99.8%, respectively.

Vegetation and Water Characteristics of an Eco-technological Water Purifying Biotope in Yongin (용인시에 위치한 생태공학적 수질정화 비오톱의 식생 및 수환경 특성)

  • Nam, Bo Eun;Kim, Jae Geun;Hong, Mun Gi
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.432-445
    • /
    • 2018
  • Vegetation and water characteristics of an eco-technological water purifying biotope were investigated at five years after the wetland construction. A total of 91 vascular plant species in 36 families were recorded. Initially planted emergent macrophytes such as Phragmites australis, P. japonicus, Zizania latifolia, Typha latifolia, and T. angustifolia mainly comprised the vegetational components of the wetland. The effect of water purification was observed markedly in most indicators such as electric conductivity (P < 0.01), $NO_3-N$ (P < 0.05), $NH_4-N$ (P < 0.001), $K^+$ (P < 0.05), $Na^+$ (P < 0.01), and $Mg^{2+}$ (P < 0.01). In particular, $NO_3-N$ and $NH_4-N$ concentrations decreased to about 60% and 30%, respectively, via the purification process of the wetland. Separativeness and curvature from the meandering structure of 15 units (multi-cell wetland system) seemed likely to make the wetland continuously play a role as an eco-technological water purifying biotope. We recommend that eco-technological design factors should be included in wetland constructions for efficient and continuous functioning, thus enhancing ecological values of wetlands.

Study on water pollution measurement and integration monitoring system with B-TOX (B-TOX를 이용한 오염수 측정 및 통합관리시스템 구현에 관한 연구)

  • Yang, Jae-Soo;Han, Yong-Hwan;Lee, Young-Ha;Kim, Yoon-Hyun;Kim, Jing-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.61-67
    • /
    • 2010
  • In operating estimation system, the river and lake is almost simple monitoring system or independent monitoring system. But the present system has many weak points about the concurrent analysis ability of various information collection. Sensors generating the information is not accurate. Therefore, we have something that can be improved. Although we have the related facilities of the purification plant, forebays and sewage disposal plant, and suffer from the difficulty about lack of system of estimation, management and control. As a result of this paper, monitoring system can observe the water pollution and various water environment of whole country. Also, through the sensors of USN, Zigbee, RFID and middle ware, which can service and construct service platform, we present standard plan of remarkable scalability service platform.

Studies on Removal of Water Pollutants by Aquatic Plants - I. Removal of Organic Matter by Water Hyacinth and Factors Affecting It's Growth (수생식물(水生植物)을 이용(利用)한 수질오염원제거(水質汚染源除去)에 관(關한) 연구(硏究) - 제1보(第1報) 부레옥잠의 유기물(有機物) 제거효과(除去效果) 및 생장(生長)에 미치는 제요인(提要因))

  • Pyon, Jong-Yeong;Lee, Kyu-Seung;Lee, Jong-Sik
    • Korean Journal of Weed Science
    • /
    • v.5 no.2
    • /
    • pp.143-148
    • /
    • 1985
  • Water hyacinth, unused and tropical plant was examined in order to know the feasibility of application for purification of municipal drainage and industrial wastewater. This plant was effective to remove the COD from wastewater, although its removal ability was dependent on the organic sources. The effects of pH, NaCl concentration, water temperature and shading condition on the growth of water hyacinth were investigated. The optimum ranges of pH were weak acid- neutral, of water temperature were 17-$21^{\circ}C$, and unshading condition was better. The rapid propagation of this plant was also observed during hot summer season.

  • PDF

Phytoremediation of Urban Air Pollution

  • Fang, Qin;Wang, Yun;Jin, Jie
    • Journal of Urban Science
    • /
    • v.8 no.2
    • /
    • pp.35-39
    • /
    • 2019
  • With the rapid progress of society and economic growth, more and more factories are put into construction, although to a certain extent to promote the development of our country's economy, but the waste gas and waste water produce also harm the environment.Among them, air pollution causes great damage to the environment and harms human health.In order to protect people's safety and health, people began to look for some measures to control air pollution, one of the most effective way is to plant more green plants, using plants for air purification.