• Title/Summary/Keyword: Water pollution process test method

Search Result 10, Processing Time 0.027 seconds

Selecting Target Sites for Non-point Source Pollution Management Using Analytic Hierarchy Process (계층분석적 의사결정기법을 이용한 비점원오염 관리지역의 선정)

  • Shin, Jung-Bum;Park, Seung-Woo;Kim, Hak-Kwan;Choi, Ra-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.3
    • /
    • pp.79-88
    • /
    • 2007
  • This paper suggests a hierarchial method to select the target sites for the nonpoint source pollution management considering factors which reflect the interrelationships of significant outflow characteristics of nonpoint source pollution at given sites. The factors consist of land slope, delivery distance to the outlet, effective rainfall, impervious area ratio and soil loss. The weight of each factor was calculated by an analytic hierarchy process(AHP) algorithm and the resulting influencing index was defined from the sum of the product of each factor and its computed weight value. The higher index reflect the proposed target sites for nonpoint source pollution management. The proposed method was applied to the Baran HP#6 watershed, located southwest from Suwon city. The Agricultural Nonpoint Pollution Source(AGNPS) model was also applied to identify sites contributing significantly to the nonpoint source pollution loads from the watershed. The spatial correlation between the two results for sites was analyzed using Moran's I values. The I values were $0.38{\sim}0.45$ for total nitrogen(T-N), and $0.15{\sim}0.22$ for total phosphorus(T-P), respectively. The results showed that two independent estimates for sites within the test water-shed were highly correlated, and that the proposed hierarchial method may be applied to select the target sites for nonpoint source pollution management.

Comparison of Instrument Characteristics on the Total Organic Carbon Analysis Method in Water Samples (수질분야 총유기탄소 분석방법에 따른 장비별 특성 비교)

  • Hye-Sung Kim;Eun-Tae Hwang;Chan-Geun Lee;Young-Cheol Cho
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.353-362
    • /
    • 2023
  • TOC, which can measure more than 90% of organic substances, can be measured quickly and easily,replacing BOD and COD, which were indicators of organic pollutants. According to water quality pollution control standards, when measuring TOC, if the inorganic carbon ratio in the sample is over 50%, the NPOC (Non-Purgeable Organic Carbon) method should be used. If volatile organic compounds (VOCs) are present at a certain concentration, the TC-IC (subtracting inorganic carbon from total carbon) method should be used. To validate the limitations of these analytical conditions, experiments were conducted by varying the ratio of TOC to IC in purified water and measuring the concentration of TOC in test solutions. The results showed no significant difference between the TC-IC method and the NPOC method. When measuring samples with added VOC standard solutions, it was observed that the carbon loss due to purging was not significant when using the NPOC method. Therefore, it is concluded that the choice of analytical method does not lead to significant differences when VOCs are present in the sample. To account for potential variations in results based on water quality pollution control standards and regulations regarding the approval and testing of environmental measurement devices, a comparison of field sample concentration values was made using two widely used types of TOC analyzers in Korea. The results showed variations of 0.02 to 0.83 mg/L between methods depending on the manufacturer, highlighting the need for caution when selecting an instrument.

A Study on Water Purification Effect of Media Block Using Porous Ceramics and Zeolite (다공성 세라믹과 제올라이트를 활용한 수질정화미디어블럭의 효과 연구)

  • Jeon, Sung-yool;Koo, Bon-hak
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.5
    • /
    • pp.59-66
    • /
    • 2017
  • Preeminent water treatment plans are essential to preserve the water quality of aquatic biotopes. Previous studies have not been sufficient to provide cost-effective maintenance method since they focused only on the purification of deteriorated water that requires a continuous supply of clean water. This study proposes an economical method of water quality maintenance using water treatment media block constructed vertically using porous ceramics, zeolite, and river pebble. The water treatment media block does not require a separate purification area because it functions as a purifier within the ecological pond which can maximize the biotope area. To evaluate the performance of the water treatment media block, we longitudinally tracked the change of water quality indicators (pH, TDS, COND, DO, T-P, T-N, COD) suggested by Water Environment Standards, Ministry of Environment, Republic of Korea. We compared the water quality of one control (A: general ecological pond composition method of the laminated structure) and two experimental groups (B: a combination of aquatic plants and a water treatment media block, C: a water treatment media block only). As a result, we confirmed that the water treatment media block is an efficient and economical method to maintaining the water quality of the ecological pond for a long time. The water treatment media block will be a great help in providing a better aquatic biotope space for aquatic insects and fishes living in clear water.

Analyzing the Differential Views between the Designers and the Users on Certification Assessment Criteria of the G-SEED System - Focused on Certification Assessment Criteria for Apartment Buildings - (녹색건축 인증제도 평가항목에 대한 설계 실무자 및 사용자 의식 차이 분석 - 공동주택 인증 평가항목을 중심으로 -)

  • Choi, Yeo-Jin
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose: The green building certification system in Korea was introduced in 2002 and developed as an improvement version of the G-SEED(Green Standard for Energy and Environmental Design) system in 2013. This study conducts surveys targeting architectural designers and users on significance of certification assessment criteria for apartment buildings on the G-SEED system and examines the differential views between the two groups on assessment criteria. Method: First, The AHP(Analytic Hierarchy Process) method was used to find importance of assessment criteria and then the importances were compared with weighted points on the certification standard. Second, the t-test was used to investigate differential views between designer and user groups on certification assessment criteria based on drawn importances. Result: (1) While designer group considered land use and transportation, energy and environmental pollution, and water circulation management as more important, user group did material and resource, maintenance management, ecological environment, and indoor environment as more important. (2) Based on t-test results, sustainable energy, water circulation system, site management, habitat, acoustical environment, and light environment were found to be different on importance between the two groups.

Efficient Management of the pH of the Wet Scrubber Washing Water for Risk Mitigation (리스크 완화를 위한 Wet Scrubber 세정수 pH의 효율적 관리)

  • Joo, Dong-Yeon;Seoe, Jae Min;Kim, Myung-Chul;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.85-92
    • /
    • 2020
  • Wet Scrubber reacts the incoming pollutant gas with cleaning water (water + absorbent) to absorb pollutants and release the clean air to the atmosphere. Wet scrubbers and packed tower scrubbers using this principle are widely used in businesses that emit acid gases. In particular, in the etching process using hydrochloric acid (HCl), alkaline washing water (NaOH) having a pH of about 8 to 11 is used to absorb a large amount of acid gas. However, These salts are attached to the injection nozzle (nozzle), filling material (packing), and the demister (Demister), causing air pollution, human damage, and inoperability due to clogging and acid gas discharge. Therefore, In this study, an improvement plan was proposed to manage the washing water with pH 3~4 acidic washing water. The test method takes samples from the Wet Scrubber flue measurement laboratory twice a month for 1 year. Hydrogen chloride (HCl) concentration (ppm) was measured, and nozzle clogging and scale conditions were measured, compared, and analyzed through a differential pressure gauge and a pressure gauge. As a result of the check, it was visually confirmed that the scale was reduced to 50% or less in the spray nozzle, filler, and demister. In addition, the emission limit of hydrogen chloride in accordance with the Enforcement Regulation of the Air Quality Conservation Act [Annex 8] met 3 ppm or less. Therefore, even if the washing water is operated in an acidic pH range of 3 to 4, it is expected to reduce air pollution and human damage due to clogging of internal parts, and it is expected to reduce maintenance costs such as regular cleaning or replacement of parts.

Evaluation of biodegradability according to bait type for crab pots (꽃게 통발용 미끼의 형태에 대한 생분해도 평가)

  • Jeong, Byung-Gon;Chang, Ho-Young;Koo, Jae-Geun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.1
    • /
    • pp.20-30
    • /
    • 2008
  • In order to evaluate the biodegradability of bait used in the pot for swimming crab, water tank experiments were conducted. Mackerel is the most commonly used natural form of bait to catch the swimming crabs, and therefore was used in this experiment for the biodegradability according to the manufacturing process of the bait. From the biodegradability test on chemical oxygen demand(COD), total nitrogen(T - N), total phosphorus(T - P), ammoniac nitrogen, nitrite nitrogen and nitrate nitrogen per unit weight of the bait based on the production rate and the accumulated amount of pollutants, it was concluded that the smaller the size of the mackerel pieces, the higher the production rate and accumulated amount of organic matter and nutrients which was unfavorable to water pollution. The amount of pollutants released from the intestine of the tuna was similar with that from the whole mackerel. For the operation period of 111 days, the accumulated concentrations of tested pollutants from the tuna which were 67.3 mgCOD/g d, 86.4 mgT N/g d, 3.1 mgT - P/g d, were almost half comparing with those from the mackerel which were 65.7 - 94.4 mgCOD/g d, 83.8 - 109.4 mgT - N/g d, 3.1 - 5.2 mgT - P/g d. The amount of pollutants released from the intestine of the tuna was slightly less than that from the mackerel that was cut into 8 pieces. but more than that from the mackerel which was not cut into pieces. Therefore, it can be concluded that the key factor in determining water pollution potential is not the kind of bait, but the processing or preparation method used.

A Study on Water Quality for Golf Course Pond in Northern Areas in Gyeonggi Porvince (경기도 북부지역 골프장연못 수질특성에 관한 연구)

  • Kim, Jae-Kwang;Hwang, Chan Won;Park, Jin-Ho;Kim, Ji Young;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.4
    • /
    • pp.323-329
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate the water quality of 16 golf course ponds located in northern areas Gyeonggi province by investigating residual pesticides, organic matters (BOD, TOC) and nutrients (TN, TP). Methods: The result data for the residual pesticides were used from 2014 to 2017. and other result data were used for April and July in 2017. The residual pesticides analytical method was based on 'Golf course residual pesticides inspection method', The others analytical method was based on 'The water pollution process test standard' Results: Very toxic pesticides and banned pesticides were not detected but general pesticides were detected. In case of the water quality of the golf course pond was applied to the lake water quality standard. In April the average TOC concentration was V grade to 6.46 mg/L, TP V grade to 0.13 mg/L, TN VI grade to 1.6 mg/L, In July TOC average concentration was VI grade to 8.65 mg/L, TP VI grade to 0.17 mg/L, TN V to 1.5 mg/L. All TN and TP concentrations corresponded to eutrophication. Compared with lake water quality monitoring, the concentrations of BOD, TOC and TP were high but the TN concentration was low in April and July. Conclusions: It is considered that water quality managements are necessary for the golf course pond. The first reason is that the pollutants of pond are discarded to river during rainfall and act as pollution sources. The second reason is that the golf course users are uncomfortable because of odor caused by the pollutants of the pond.

Effect of Slag Dumping on Heavy Metals in the Neighbour Sea and Direction of Recycling on Slag (제철 슬래그(Slag) 매립으로 인한 인근 해역의 중금속 오염도 변화 및 재활용 방향에 대한 연구)

  • Chung, Yong;Kim, Yong-Bum;Kwan, Yong-Sik;Lee, Sun-Hi
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.2
    • /
    • pp.21-31
    • /
    • 1996
  • To assess the impact resulted from the slag dumping, we studied that the changes in the concentration of heavy metal were researched through the statistic analysis at 4 stations in Yongil bay, Korea from 1988 to 1995. And in order to clarify resulting from the changes in heavy metal concentration due to be leaked out from dumped slag, it was fulfilled experiments of the slag extraction. In the extracting experiment, Pb and As were only leaked out from slag aged during 10 days but all of heavy metals were not from it aged during 90 or 180 days. It was found that the concentrations of heavy metals in sea water of vincinity of slag dumping area were still remained in similar, comparing with it of control site(site 4) when they were by analysed statistic method, anova test and Mann-Whitney test. The slag recycling ratio of our country is lower than foreign country. While we need to apply a new process for phosphate treatment, foreign country already apply a slag to phosphorous removal. We suggest that slag dumping cannot putatively affected the changes in the concentration of heavy metal. And we thought that impact of heavy metal induced by slag dumping was not severe. So, it is necessary to utilize this process in phosphorous removal, like a foreign country.

  • PDF

Dynamic Properties of the Mortar Utilizing the Polysilicon Sludge as the Cement Admixture Material (시멘트 혼화재로써 폴리실리콘 슬러지를 활용한 모르타르의 역학적특성)

  • Lim, Jeong-Geun;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.240-241
    • /
    • 2014
  • The environmental pollution problem the globally related to global warming arises. In the construction industry the cement mostly use material, generates the great quantity of CO2 among the fired process and the global warming is more aggravated. In addition, the polysilicon that is the main raw material used in the solar power generation, produces 1 ton and the industrial by-product of 2 tons is generated. In this way, the arising sludge there is not method recycling and it is all discarded. Therefore, in this research, try to present as the fundamental research material for using the polysilicon sludge as the admixture of the cement in order to reduce the amount of the cement. The based on 'KS L ISO 679' was progressed mortar test. the liquidity, air flow rate, setting time, water absorption ratio, flexural and compression strength was measured. According to, appropriate replacement ratio of the polysilicon sludge tries to analyze.

  • PDF

Numerical Formulation for Flow Analysis of Dredged Soil (준설토 유동해석을 위한 유한요소 수식화)

  • Shin, Hosung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.3
    • /
    • pp.41-48
    • /
    • 2014
  • Experimental study of sedimentation and self-weight consolidation has been primary research area in dredged soil. However, good quality of the dredged soil and minimum water pollution caused by the pumping of reclaimed soil require intensive study of the flow characteristics of dredged material due to dumping. In this study, continuity and the equilibrium equations for mass flow assuming single phase was derived to simulate mass flow in dredged containment area. To optimize computation and modeling time for three dimensional geometry and boundary conditions, depth integration is applied to governing equations to consider three dimensional topography of the site. Petrov-Galerkin formulation is applied in spatial discretization of governing equations. Generalized trapezoidal rule is used for time integration, and Newton iteration process approximated the solution. DG and CDG technique were used for weighting matrix in discontinuous test function in dredged flow analysis, and numerical stability was evaluated by performed a square slump simulation. A comparative analysis for numerical methods showed that DG method applied to SU / PG formulation gives minimal pseudo oscillation and reliable numerical results.