• Title/Summary/Keyword: Water pollutants

Search Result 1,455, Processing Time 0.023 seconds

Experiment for Reduction Effectiveness of Pollutants with the Improvement of Infiltration Ability in Vegetation Filter Strip (식생여과대내 침투능력 향상에 따른 오염물질 저감효과에 대한 실험)

  • Lee, Young-A;Choi, I-Song;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.183-190
    • /
    • 2007
  • Soil layer in vegetation filter strip is one of the very important factor for reduction of non-point pollutants by physical, chemical and biological reactions of it through infiltration process. This study was carried out to prepare more effective vegetation filter strip through modification of soil layer for river water quality improvement. Therefore, the main aims of this study are to compare and evaluate normal (straighten type) and modified (step type) vegetation filter strip, which make artificially change the soil layer to improve infiltration ability, through bench scale experiments. In the results of this study, vegetation filter strip of step type is much more highly reduction effectiveness of pollutants in surface flow compared with normal vegetation filter strip. In case of below effluent, however, it appeared that the vegetation filter strip modified soil layer showed lower reduction effectiveness of pollutants than the general vegetation filter strip. This result was judged because effluent through the vegetation filter strip of step type passed bigger size of aggregate or sand than the vegetation filter strip of straighten type. If we compare it as a definition of pollutant load to estimate total amount of reduced pollutants by vegetation filter strip, reduced pollutants load by step type showed higher than those by straighten type because below effluent amount relied on total effluent amount was higher at step type (4%) than at straighten type (2%). In conclusion, the vegetation filter strip of step type to improve infiltration effect is much more reduction effectiveness of pollutants than vegetation filter strip of straighten type.

Outflow Loads of Total Nitrogen, Total Phosphorus, and COD in Mountain Stream Water (산지 계류수에서의 총질소, 총인 및 COD의 유출부하)

  • Kim, Jin-Soo;Kim, Sun-Jong;Oh, Kwang-Young;Oh, Seung-Young;Kim,Je-Su;Jeong, Young-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.787-797
    • /
    • 2003
  • The characteristics of concentrations and loads of Total Nitrogen(T-N), Total Phosphorus(T-P), and Chemical Oxygen Demand (COD) in mountain stream water were examined from September 2000 through August 2001. The 92.5-ha study watershed in Chungbuk Province consists of 59% mixed forest and 30% coniferous forest. Streamflow was measured and water samples were collected at about 10 day intervals for dry days and at 2-6 hour intervals for a storm event at the study watershed outlet. The mean concentration of COD in streamflow for rainy days was significantly (p < 0.05) higher than for dry days. The mean concentrations of T-N and T-P in vegetation growing season (May to October) were lower than those in vegetation dormant season (November to April). Low concentrations of pollutants during vegetation growing season are likely due to the heavy demand for nutrients by the vegetation and biological activity associated with a warming of soil. The ratios of pollutants loads during storm periods to annual pollutants loads were 87% for T-N, 83% for T-p, and 87% for COD. The unit loads of pollutants for study area were estimated at 5.9 kg/ha $\cdot$ yr for T-N, 0.15 kg/ha $\cdot$ yr for T-p, and 23.9 kg/ha $\cdot$ yr for COD. The removal efficiency of pollutants in study area were 24% for T-N, 58% for T-P and 66% for COD, indicating that a study area shows water purification function.

Estimation of Pollutants Loads using Unit Load Method in Hong-Bo Watershed (원단위법을 이용한 홍보유역의 오염부하량 산정)

  • Kim, Sun-Joo;Lee, Suk-Ho;Heo, Bae-Young
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.492-496
    • /
    • 2001
  • The purpose of this study is to estimation of pollutants loads using unit load method in Hong-bo watershed. In general, because river water quality management have been conducted with point source pollutant in our country, pollutants caused by precipitation have not been managed well so far. Especially the pollutants tends to concentrate in the reservoir of reclaimed land. Therefore, the reservoir of reclaimed land is need to continuous monitoring and update of an accurate data. also, It is need to improvement of environmental pollution. There are divide into nine sub-catchments and made an estimate of pollutants loads using unit load method in Hong-bo basin. The sample of data was during the 10 years.

  • PDF

A study on Compare Characteristics of Nonpoint Source in Storm-water versus Steepness of Field Slope (밭경사에 따른 강우유출수 내의 비점오염물질 특성 비교 분석)

  • Kim, Gi-Cheol;Choe, Yong-Hun;Won, Cheol-Hui;Choe, Jung-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1093-1102
    • /
    • 2009
  • This study was focused on analyse Nonpoint source characteristics from Flat slope field and Steep slope field. We performed Storm-water monitering for obtain flow data and concentration data. Totally, eleven times Event was occurred. We calculated EMC(Event Mean Concentration) and Pollutants Loads using data we obtained. As a result, steep slope field has more discharge than flat field. SS value, one of the water quality contents, has largest variation and T-N has least variation. There is runoff differences even though events has same rainfall. We assume that not only amount of Rainfall, but also Rainfall Duration Times, Intensity, Number of Previous Non-precipitation days can affect to Run-off.

  • PDF

Evaluation of Treatment Efficiencies of Water Quality for 5 years in Constructed Wetland to Upper Region of Water Source (상수원 상류지역 인공습지의 5년간 수질 정화효율 평가)

  • Park, Jong Seok;Kim, Kang Seok;Kim, Yong Chan;Rhee, Kyoung Hoon
    • Journal of Wetlands Research
    • /
    • v.14 no.4
    • /
    • pp.479-488
    • /
    • 2012
  • This study evaluates treatment efficiencies of pollutants in Boknae bio-park constructed wetlands surrounding Juam Lake for 5 years from January 2006 to December 2010, in order to treat non-point pollutants effectively. The analysis of monthly treatment efficiency of pollutants shows that the scope of BOD is -19.11~37.72%, and of COD is 30.14~27.38%, thus the monthly deviation COD is relatively higher than BOD, and the scope of SS is -54.07~64.82%. Moreover, the analysis of seasonal treatment efficiency of pollutants shows that the treatment efficiency of TN is higher than 36.8% on average for 5 years in the spring and winter, and of TP relatively lower than other pollutants, however, the seasons don't make much difference to the treatment efficiency of TP.

Water Quality Modeling for Environmental Management in Chinhae.Masan Bay (진해.마산만의 환경관리를 위한 수질모델링)

  • 조흥연;채장원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.1
    • /
    • pp.41-49
    • /
    • 1999
  • The horizontal two-dimensional model which can predict the long-term water quality(WQ) change is setup for the environmental management. For the model calibration and verification, we measured the pollutants load at 22 streams and the WQ at 16 stations monthly and/or seasonally in Chinhae . Masan Bay. The pollutants release rate from the sediment was also measured to consider the regionally different sediment pollution level. From the model application results, it is shown that the WQ concentrations in most of the regions adjacent to land and river inflow are considerably high, but rapidly decrease along the seaward direction. In Masan Bay, the particulate inflow-pollutants were substantially deposited and gradually contaminated the bottom sediment on account of the excessive pollutants load and flow stagnancy. Eutrophication in the effluent discharge region was also being slowly progressed by the inefficiently treated wastewater containing amount of Nand P constituents.

  • PDF

Estimation of Pollutants Residence Time During the Flood and Dry Season in Gwangyang Bay (광양만의 홍수기 및 갈수기의 오염물질 체류시간 산정)

  • Lee, In-Cheol;Kim, Jin-Hyuk;Kong, Hwa-Hun
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.20-26
    • /
    • 2008
  • In this paper, in order to set up the management system of water quality environment in Gwangyang Bay, the cluster analysis of water quality environment, the estimation of inflowing pollutant loads and residence time of pollutants in this bay was carried out. The Gwangyang Bay was divided into eight sea areas by cluster analysis and spatio-temporal change of water quality. The river discharges in the Bay were calculated about $11,681{\times}103m^3/day$ from the numerical simulation by Tank model. In addition, inflowing pollutant loads of COD, SS, TN, TP, DIN and DIP in Gwangyang Bay were estimated at 398 ton-COD/day, 2,846 ton-SS/day, 195 ton-TN/day, 5 ton-TP/day, 126 ton-DIN/day and 3 ton-DIP/day, respectively. Moreover, residence times of COD, TN and TP in the Bay was estimated at 6 days-COD, 20 days-TN and 195 days-TP, respectively in the dry season, and 3 days-COD, 6 days-TN and 21 days- TP, respectively, in the flood season. The central part of Gwangyang Bay (Region IV) has the longest residence time of overall pollutants.

Unit Loads of Pollutants in a Paddy Fields Area with Large-Scaled Plots during Irrigation Seasons (관개기 대구획 광역논에서의 오염부하 원단위)

  • 오승영;김진수;김규성;김선종;윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.2
    • /
    • pp.136-147
    • /
    • 2002
  • Characteristics of unit loads of pollutants were investigated at a paddy fields area(Soro-ri) with large-scaled plots on loam soil during irrigation seasons of 1999 ∼2000. The average irrigation requirement of experimental paddy area are estimated at over 3,000 mm. The unit loads of pollutants in paddy fields area are determined by subtracting irrigation water load from outflow load (percolated and surface outflow loads). Surface outflow load in rainy days was calculated using the relationships of discharge and load, which are grouped into fertilizing and non-fertilizing periods. The ratios of the surface outflow load in rainy days to the total surface outflow load are 16.4% for T-N, 26.8% for T-P, and 23.3% far CODc,. The unit loads of pollutants show month-to-month and year-to-year variations, and monthly unit load of pollutants can show negative values, indicating that the paddy area acts as the pollutants sink. The average unit loads of the pollutants during irrigation seasons were estimated at 18.2 kg/ha fur T-N, 0.31 kg/ha for T-P, and 43.3 kg/ha for CODc,, which are smaller than the reported values for Kosei area in Japan.