• Title/Summary/Keyword: Water main

Search Result 4,628, Processing Time 0.034 seconds

Water Quality Management Plan through Mass Balance at Small Urban Stream (중.소 도시하천의 물질수지를 통한 수질관리 방안 도출)

  • Oh, Jong-Min;Shin, Dong-Hwan;Choi, I-Song
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.1 s.12
    • /
    • pp.51-56
    • /
    • 2004
  • In this study, the variation of water quality in Osan stream was investigated through continuous monitoring, and mass balance and metabolism occurred into water body were estimated to set up effective management plan for water quality of small urban stream. From the results of continuos investigation of water quality in Osan stream, the things written as follows must be previously done to improve water quality of main stream. Firstly, it need that effective management plan for tributaries must be set up to improve the water quality in main stream. Secondly, the counter plan for re-eruption of pollutants from sediment in main-stream is required to prevent inner pollution. In this study, we showed that small urban stream can be managed effectively by simple investigation to prevent deterioration of water quality. Therefore continuous monitoring for water quality in stream is important to improve water quality, furthermore matter cycle and mass balance happening in the stream environment must be correctly estimated to make up healthy stream environment.

Evaluation of Water Quality and Phytoplankton Community Using a Multivariate Analysis in Bukhan River (다변량 통계분석을 이용한 북한강의 수질 및 식물플랑크톤 군집 특성 평가)

  • Kim, Hun Nyun;Youn, Seok Jea;Byeon, Myeong Seop;Yu, Soon Ju;Im, Jong Kwon
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.19-27
    • /
    • 2019
  • The purpose of this study is to evaluate the water quality and phytoplankton community in Bukhan River which account for 44.4 % of the total inflow into Lake Paldang, using multivariate statistical techniques (i.e., correlation analysis, principal component analysis (PCA)/factor analysis (FA)). Water samples were collected from March to November 2015 and the following parameters measured; water temperature, pH, DO, EC, SS, BOD, Chl-a, COD, TN, $NO_3-N$, $NH_3-N$, TP, DTP, $PO_4-P$, and phytoplankton community. The water quality of the main stream and the tributaries were not significantly different apart from the relatively high concentration of BOD, COD and nutrients recorded in MH. The highest cell density of Stephanodiscus hantzschii and Merismopedia glauca dominated phytoplankton was observed in PD. Based on the correlation analysis, total phytoplankton and cyanophyceae were highly correlated with BOD, COD and nutrients. PCA/FA resulted in four main factors accounting for 82.240 % of the total variance in the water quality dataset. The group of component 1 (TN, DTN, DO, $NO_3-N$, water temperature) and component 2 ($PO_4-P$, T-P, DTP, SS) were classified as nutrient element factor whereas component 3 (Chl-a, COD, BOD, $NH_3-N$, pH) was related to organic substances. Hence, the identification of the main potential environmental pollution factors in Bukhan River will help policy makers make better and more informed decisions on how to improve the water quality.

A Study on the cause and permanent measures on trouble of the GCB for the Main Tr. of Voltage, 154kV (154kV 주변압기용 가스차단기(GCB) 소손에 따른 원인규명과 항구대책 분석)

  • Jeon, Kyu-Nam;Chang, Moon-Soung;Ock, Gwang-Seok;NamGoong, Hyuk;Ahn, Joo-Hoon;Jeong, Jae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.285-286
    • /
    • 2008
  • The Gas Circuit Breaker for the Main Transformer of voltage, 154kV at the ist Hapcheon hydraulic power station, break down by the falling of a thunderbolt from now, let's improve the efficiency on the maintenance of generating equipment by studying about the cause and the method for this problem.

  • PDF

Feasibility Study of Multi-regional Transmission Main Stabilization for Sustainable Water Supply (수돗물 공급 안정화를 위한 광역상수도 관로 안정화 타당성 연구)

  • Lee, Jae Bum;Yi, Choong Sung;Jung, Kwan Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.395-404
    • /
    • 2013
  • The risk of pipe-bursting in multi-regional transmission mains consisting of 89 % of singled pipeline is so high that pipeline stabilization project is required such as renewal and replacement, pipe paralleling, emergency ties. Pipeline stabilization projects could be postponed at the step of initial decision-making because effect of this project is intangible benefit like activation of economic, improvement of welfare related to water. This study is to suggest quantified economical feasibility model for intangible benefit presumption to solve above problem. Cost reduction of emergency water supply, leakage, burst restore and energy efficiency improvement was altered and applied. As a result of economic analysis taking into account estimated benefit and cost under discount rate 5.5 %, service life 40 years, sufficient economic feasibility analyzed with B/C 2.45, NPV 317,700 million won, IRR 9.09 %.

The flow characteristics of a Main Cooling Water System for Nuclear Fuel Test Loop Installed in HANARO (하나로 핵연료 시험루프의 주냉각수 계통 유동해석)

  • Park, Young-Chul;Lee, Young-Sub;Chi, Dai-Yong;Ahn, Seong-Ho;Kim, Yong-Ki
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.444-447
    • /
    • 2008
  • A nuclear fuel test loop (after below, FTL) is installed in IR1 of an irradiation hole in HANARO for testing neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor (PWR) or a heavy water power reactor (CANDU). There is an in-pile section (IPS) and an out-pile section (OPS) in this test loop. When HANARO is normally operated, the fuel loaded in the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain an operation condition of the test fuel, a main cooling water system (MCWS) is installed in the OPS of the FTL. The pump can not continuously suck a fluid and not pressurize the fluid during a cold function test. To verify the flow characteristics of the MCWS, a flow net work analysis has been conducted. When the higher elevation pipelines wholly filled with coolant, it was confirmed through the analysis results that the pump pressurized the coolant normally. And the analysis results described the system characteristics with operation temperature and pressure variation satisfactorily.

  • PDF

The Effect of Current and Temperature of a Reservoir by the Simulation of Dam Outflow (댐 방류조건에 따른 저수지 유속과 수온 영향)

  • Yu, Soon-ju;Ha, Sung-ryong;Jung, Dong-il
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1060-1067
    • /
    • 2006
  • Water quality in the Daecheong reservoir has been deteriorated by algal bloom due to nutrient supply from the upstream of the Daecheong reservoir after heavy rainfall. Algal bloom is propagated from eutrophicated tributary into the main body of the reservoir according to the hydrological conditions. This study is aimed to estimate the water current and temperature effect by the simulation of dam spill flow control using water quality model, CE-QUAL-W2 in 2003. Water current was resulted in nutrient transport from upstream of main reservoir and nutrients were delivered up to downstream by fast water velocity. Algal blooms occurred in stagnate zone of reservoir downstream as the current of downstream was retarded according to dam outflow control. Consequently water balance in stagnate zone triggered a rise of water temperature in summer. It affected algal bloom in the embayment of the reservoir. The simulation result by outflow control scenarios showed that spill flow augmentation induced in water body instability of stagnate zone so that water temperature declined. It could be suggested that outflow control minimize algal bloom in the downstream in the flooding season as long as water elevation level is maintained properly.

Operation and Diagnosis of DAF Water Treatment Plant at Highly Turbid Raw Water (고탁도시 DAF 정수장의 운영 및 진단)

  • Kwon, Soon-Buhm;Ahn, Hyo-Won;Kang, Jun-gu;Son, Byong-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.191-200
    • /
    • 2004
  • DAF process has been designed considering raw water quality characteristics in Korea. Although direct filtration is usually operated, DAF is operated when the freshwater blooms occut or raw water turbidity become high. Pre-sedimentation iS prepared in case when raw water turbidity is very high by rainstorms. A main feature of this plant is that the operation mode can be changed (controlled) based on the characteristics of raw water to optimize the effluent quality and the operation costs. Treatment capacity (surface loading rate) and efficiency of DAF was found to be better than conventional sedimentation process. Moreover, low-density particles (algae and alum flocs) are easily separated while it is difficult to remove in sedimentation. One of the main concerns in adoption of DAF (Dissolved Air-Flotation) process is a high raw water turbidity problem. That is, DAF is not adequate for raw water, which is more turbid than 100NTU. In order to avoid this problem, pre-sedimentation basins are prepared in DAF plant to decrease the turbidity of DAF influent. For simulation of the actual operation, bench and full-scale tests were performed for highly turbid water conditions. Consequently, DAF process coupled with sedimentation is suggested that pre-sedimentation with optimum coagulation prior to DAF would be appropriate.

A Survey on the Sanitary Condition of Water Source and Toilet in Korean Rural Area. (-부농촌지역이 상하중 위생실태조사)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.4 no.1
    • /
    • pp.41-46
    • /
    • 1977
  • Main objectives of this survey were to find out general sanitary status of water source, draining status and toilet in Shindong Myun, Chungseong Gun. Interviewers of fourteen students visited 1,775 households in this Myun, filled the survey form and checked sanitary conditions of the areas from September 1 to November 30, 1974. Results are summarized as follows: 1. Draining state of pumps is better than that of wells and also the the quality of water sources are better in pumps than in wells. Wells and pumps of 54.1% were constructed more than five years ago. 2. About 66.7% use pump water, 10.5% well water and 8.3% simple piped drinking water system and average water consumption is 22.7l per day per capita. Private water system is 66.0% while public system 27.1%. 3. Water is used for drinking, washing body and cleaning at 53.8% while only for drinking at 7.4%. 4. Nearest pollution sources of drinking water are mainly toilets and stables, and average distances between them are less than ten meters. 5. Toilets of 78.3% are used only by one households and those of 12.9% by two. 6. Toilets of 10.9% are inside main building while those of 85.4% outside main building. 7. Toilet tanks are covered only at 6.3% households while not covered at 95.4%. The contents of tanks are removed about twice a month (40.2%), and 84.1% use them as fertilizer on their own farm and contents of 10.1% are removed by other people. 8. Excreta are utilized on the vegetable farm by 38.2% households, on the vegetable and barley farms by 19.7% and on the paddy fields by 8.2%.

  • PDF

A Study on Characteristics of Water Quality using Multivariate Analysis in Sumjin River Basin (다변량 분석법을 이용한 섬진강 수계의 수질 특성 연구)

  • Park, Jinhwan;Moon, Myungjin;Lee, Hyungjin;Kim, Kapsoon
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.119-127
    • /
    • 2014
  • The objective of this study is to evaluate and analyze Sumjin River Basin water environment system. It was necessary to improve the water quality. The data were collected from 2010 January to 2012 December including Water Temperature, pH, DO, EC, $BOD_5$, COD, TOC, SS, T-N, T-P. The data were used to study were required to; Correlation Analysis; Principle Component Analysis; Factor Analysis. The results were as followed. According to correlation analysis on $BOD_5$ against COD, TOC it revealed that the each value of correlation coefficient were 0.715 and 0.719; this means the strength of the relationship is strong. The same analysis on T-P against $BOD_5$, COD, TOC, SS has revealed that the range of the correlation coefficient value fell between 0.482 and 0.608 which means strength of the relationship between them remained normal. Through correlation analysis, it has been found that all elements except T-N have high correlation. The results of principal component analysis to target the overall water quality was extracted to three main components. The cumulative contribution rate is 68.990%. In the case of seasonal water quality, Spring and Summer are extracted to each of four main components. The cumulative contribution rate is 81.515% and 73.550% respectively. Fall and Winter are extracted to each of three main components. The cumulative contribution rate is 65.072% and 72.721% respectively. There is no seasonality in the case of factor analysis. The first common factor is $BOD_5$, COD, TOC, SS, T-P, which were classified. Totally speaking, Sumjin River Basin water system gets highly affected by the nutrient salts, organic matter and suspended solid at the same time.

Water Quality Assessment of Major Drinking Waters in Natural Parks (자연공원내 주요 음용수의 수질환경평가)

  • Yi, Youngkyoung;Yi, Pyongin;Hong, Sungchul
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.439-453
    • /
    • 2018
  • The purpose of this study is to evaluate water quality characteristics of main drinking waters in natural parks, for providing the basic information of water quality and to propose the appropriate management method. to maintain the water quality standards. As a result of the analysis, microorganisms were mostly detected in the nature of natural park. And some sites are currently using UV sterilizer and ozone treatment, and it is considered appropriate to extend the use to other main drinking water. It is also good to boil drinking water at home. Turbidity is expected to improve through environmental cleanup. Overall, the main drinking water in the natural park is suitable for water quality standards, and it is considered that maintenance such as cleaning is necessary.