• 제목/요약/키워드: Water filling rate

검색결과 90건 처리시간 0.025초

수압시험 시 관 단면적 비 및 충수 속도별 탱크 내부 과압 발생에 관한 해석 (Analysis of Internal Overpressure by Pipe Cross-Sectional Area Ratio and Filling Rate in the Hydraulic Test of Shipboard Tank)

  • 김근곤;이탁기
    • 대한조선학회논문집
    • /
    • 제60권6호
    • /
    • pp.460-472
    • /
    • 2023
  • This study was conducted based on the case of an accident (excessive deformation) that occurred during the hydraulic test of a shipboard tank manufactured in accordance with the design regulations. Over-pressure phenomenon was noted as the main cause of accidents in the process of testing tanks without physical damage, which can be found in external factors such as cross-sectional difference between inlet pipe and air pipe and higher water filling rate than the recommended one. The main goal of this paper is to establish a safe water filling rate according to the range of sectional area ratio(SAR) reduced below the regulations for each test situation. The simulation was conducted in accordance with the hydraulic test procedure specified in the Ship Safety Act, and the main situation was divided into two types: filling the tank with water and increasing the water head to the test pressure. The structural safety evaluation of the pressure generated inside the tank and the effect on the structure during the test was reviewed according to the SAR range. Based on the results, guidelines for the optimal filling rate applicable according to SAR during the hydraulic test were presented for the shipboard tanks used in this study.

The gob-side entry retaining with the high-water filling material in Xin'an Coal Mine

  • Li, Tan;Chen, Guangbo;Qin, Zhongcheng;Li, Qinghai;Cao, Bin;Liu, Yongle
    • Geomechanics and Engineering
    • /
    • 제22권6호
    • /
    • pp.541-552
    • /
    • 2020
  • With the increasing tension of current coal resources and the increasing depth of coal mining, the gob-side entry retaining technology has become a preferred coal mining method in underground coal mines. Among them, the technology of the gob-side entry retaining with the high-water filling material can not only improve the recovery rate of coal resources, but also reduce the amount of roadway excavation. In this paper, based on the characteristics of the high-water filling material, the technological process of gob-side entry retaining with the high-water filling material is introduced. The early and late stress states of the filling body formed by the high-water filling materials are analyzed and studied. Taking the 8th floor No.3 working face of Xin'an coal mine as engineering background, the stress and displacement of surrounding rock of roadway with different filling body width are analyzed through the FLAC3D numerical simulation software. As the filling body width increases, the supporting ability of the filling body increases and the deformation of the surrounding rock decreases. According to the theoretical calculation and numerical simulation of the filling body width, the filling body width is finally determined to be 3.5m. Through the field observation, the deformation of the surrounding rock of the roadway is within the reasonable range. It is concluded that the gob-side entry retaining with the high-water filling material can control the deformation of the surrounding rock, which provides a reference for gob-side entry retaining technology with similar geological conditions.

우수저류조의 형상과 도류벽 및 자갈채움에 따른 SS 제거효율 (SS Removal-rate Efficiency of Storm-water Detention Storage Tank Depending upon Length, Inside Training Wall and Gravel Filling)

  • 이종태;서홍준;서경아
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.655-667
    • /
    • 2009
  • An experimental study is performed on reducing the pollutants supplied by storm water through enhancing efficiency of SS from the detention storage tank where CSOs are kept temporarily before discharge to the receiving water system. SS removal efficiency is investigated in accordance with various conditions of the detention pond-such as its length, the existence of training wall, and the use of gravel filling. The removal efficiency is strongly affected by the detention pond's length until the critical falling distance of the suspended solids is reached. For cases where the tank has a length longer than this critical condition, the removal rate shows less sensitivity. To enhance the SS removal efficiency of tanks of shorter than the critical length, we studied alternative types of tank in which inside training walls are installed. The results showed improvement of 14 to 37% in removal efficiency in 2hours detention(2 training walls). The important factor in achieving a high SS removal rate is ensuring the critical length of the detention pond, but for the cases where the basin length cannot be guaranteed, baffles or a gravel filling scheme may be introduced to attain considerable efficiency. The results of studying and comparing different storage tank conditions show that, in terms of elimination efficiency, a storage tank with gravel filling and training walls > a storage tank with gravel filling > a storage tank with training walls > an empty tank. The experimental results should contribute to development of related further research, by empirically verifying the already assumed importance of critical falling distance, training walls, and gravel filling schemes.

지하수 포화 석회석 채굴공동에서의 골재 충전 및 임시배수시 발생하는 지하수 유동 평가 (Evaluation of Groundwater Flow by Gravel-Filling and Temporary Drainage in Groundwater-saturated Limestone Mine Cavities)

  • 최우석;강병천;김은섭;신동춘
    • 터널과지하공간
    • /
    • 제27권4호
    • /
    • pp.205-216
    • /
    • 2017
  • 지하수위 변동은 석회석 폐광산에서 발생하는 지반침하의 주된 요인이다. 본 연구에서는 지하수로 포화된 석회석 채굴공동에서 발생하는 지하수 유동을 자연상태와 골재 충전, 임시배수로 구분하여 지반 안정성에 미칠 영향을 3차원 지하수 유동 해석을 통해 평가하였다. 해석 결과 골재 충전시 지반 및 소류지의 지하수위가 상승하였지만 강우나 소류지 농업용수 사용으로 발생하는 수위차 보다 작고 유속 또한 자연상태의 유속과 유사하게 나타났다. 임시배수시에는 지반 및 소류지의 지하수위가 급격하게 하강하고 공동 내 유속이 최대 25배 이상 증가하는 것으로 나타나 지반침하 위험성이 증가하는 것으로 나타났다.

Concentric Double Pipe 열교환기에서 냉각수 급랭 현상의 모사에 대한 연구 (Study on Simulation of Cooling Water through Concentric Double Pipe Heat Exchanger )

  • 최안철;이성우;신익호;최성웅
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.741-747
    • /
    • 2023
  • In this study, the heat transfer characteristics were numerically analyzed to investigate the possibility of utilizing cooling water using liquid nitrogen. From the study, as the mass flow rate of the hot fluid increased, the heat transfer rate increased by 8.9-81.7%. And lowering the inlet temperature of the hot fluid resulted in increase in the heat transfer rate by 33.8-71.5%. As for the filling level of liquid nitrogen, as higher filling level led to a decrease in the outlet temperature and an increase in the overall heat transfer coefficient.

스테인리스-아세톤 히트파이프의 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of Stainless-Acetone Heat Pipe)

  • 강금춘;김영중;유영선;백이;이건중
    • Journal of Biosystems Engineering
    • /
    • 제25권6호
    • /
    • pp.489-496
    • /
    • 2000
  • This study was conducted in order to find an ideal working fluid kind and a proper filling amount in the heat pipe as well as an inclined angle of heat pipe when they are placed to recover exhaust gas heat in the hot air heater. Followings are the findings of this research. 1. Of the four different working fluids-gasoline kerosene distilled water and acetone-acetone filled heat pipe showed the best performance giving out more homogeneous temperature profile on the radiating part than the kerosene and gasoline heat pipe an carrying out heat transmitting function better than the distilled water heat pipe by 10~2$0^{\circ}C$ higher on the radiating part. Acetone would be a good choice for recycling of exhaust gas heat in the hot air heater. 2. Of the filling amount of working fluid inside the heat pipes dry-out situations possible caused by insufficient filling were found in the filling amount of 5, 7.5 and 10% heat pipes as heat supply rate increases gradually in the range of 50 to 15kJ/sec. but no dry-out and stabilized heat transmitting performance occurred in the heat pipes of 12.5 and 15% filling at the same heat supply rate. It recommends that filling amount shall exceed 12.5% at least with the working fluids of this experiment. 3. The test revealed that the heat transmitting performance of heat pipe was more affected by filling amount rather than inclined angle.

  • PDF

Sum-Rate Optimal Power Policies for Energy Harvesting Transmitters in an Interference Channel

  • Tutuncuoglu, Kaya;Yener, Aylin
    • Journal of Communications and Networks
    • /
    • 제14권2호
    • /
    • pp.151-161
    • /
    • 2012
  • This paper considers a two-user Gaussian interference channel with energy harvesting transmitters. Different than conventional battery powered wireless nodes, energy harvesting transmitters have to adapt transmission to availability of energy at a particular instant. In this setting, the optimal power allocation problem to maximize the sum throughput with a given deadline is formulated. The convergence of the proposed iterative coordinate descent method for the problem is proved and the short-term throughput maximizing offline power allocation policy is found. Examples for interference regions with known sum capacities are given with directional water-filling interpretations. Next, stochastic data arrivals are addressed. Finally, online and/or distributed near-optimal policies are proposed. Performance of the proposed algorithms are demonstrated through simulations.

역전 유동층에 의한 슬러리아이스 생성에 관한 연구 (A study on formation of slurry ice by the reversing flow)

  • 오철;문성배;최영규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.376-381
    • /
    • 2006
  • This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank. brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.

역전 유동층 내에서의 슬러리아이스 생성에 관한 실험적 연구 (An experimental study on formation of slurry ice in reversing flow)

  • 최영규;윤석훈;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.49-50
    • /
    • 2006
  • This study experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank, brine tank. pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter, data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.

  • PDF

Power Allocation Optimization and Green Energy Cooperation Strategy for Cellular Networks with Hybrid Energy Supplies

  • Wang, Lin;Zhang, Xing;Yang, Kun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권9호
    • /
    • pp.4145-4164
    • /
    • 2016
  • Energy harvesting is an increasingly attractive source of power for cellular networks, and can be a promising solution for green networks. In this paper, we consider a cellular network with power beacons powering multiple mobile terminals with microwave power transfer in energy beamforming. In this network, the power beacons are powered by grid and renewable energy jointly. We adopt a dual-level control architecture, in which controllers collect information for a core controller, and the core controller has a real-time global view of the network. By implementing the water filling optimized power allocation strategy, the core controller optimizes the energy allocation among mobile terminals within the same cluster. In the proposed green energy cooperation paradigm, power beacons dynamically share their renewable energy by locally injecting/drawing renewable energy into/from other power beacons via the core controller. Then, we propose a new water filling optimized green energy cooperation management strategy, which jointly exploits water filling optimized power allocation strategy and green energy cooperation in cellular networks. Finally, we validate our works by simulations and show that the proposed water filling optimized green energy cooperation management strategy can achieve about 10% gains of MT's average rate and about 20% reduction of on-grid energy consumption.