• Title/Summary/Keyword: Water area

Search Result 11,314, Processing Time 0.041 seconds

Rainwater Harvesting Potential in a New Residential Area in North Bujumbura, Burundi

  • Kheria, Mfuranzima;Kang, Daeseok;Sung, Kijune
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.447-456
    • /
    • 2016
  • Access to clean and affordable water is one of the fundamental human rights because water is essential to life and a foundation for socioeconomic development of any country in the world. Despite the efforts to secure water supply in Burundi, the amount of water supplied by public utilities does not meet the demand of the population because population keeps increasing with fluctuation of weather conditions. This study selected north Bujumbura that is a sprawling new residential area in the western part of Burundi as a case to investigate the potential of rainwater harvesting in meeting water demand of the country. Based on a long-term average monthly precipitation in the region, the rainwater harvesting potential was assessed as a function of roof sizes, number of households, and runoff coefficients of roof materials. For the entire region of north Bujumbura, the current water supply capacity of the local water company combined with the rainwater harvesting potential resulted in the water surplus of $468,604.1m^3/yr$. Although three communes among them still showed water deficit in dry season, they still got help from rainwater to relieve their water shortage. This suggests that at the regional scale, proper storages and water quality control for harvestable rainwater could contribute to relieving the regional water shortage and allow the population growth.

Strategies to improve irrigation water management for rice production in Pulangui River Irrigation System

  • Siem, Paul Roderick M.;Ahmad, Mirza Junaid;Choi, Kyung-Sook
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.509-509
    • /
    • 2022
  • Rice has always been the anchor of food security in the Philippines and the government is adamant about sustaining rice production by ensuring reliable irrigation water availability. Among the numerous irrigation schemes, the importance of the Pulangui River Irrigation System (PRIS) is undeniable, as it is the largest and primary irrigation source for rice production areas which are considered the food basket in Northern Mindanao. However, the ageing irrigation structures, unlined canals, long-standing water delivery systems, and climate change are compromising the performance of PRIS; and every year, during the dry and wet season, the maximum rice irrigable area is not achieved. From the field-scale water management perspective, untimely irrigation application, an unregulated roster of turn for irrigation among farmers, and the traditional practice of flooding the rice fields are the main causes of substantial water losses in conveyance, distribution, and farm application of irrigation water. Hence, proper irrigation scheduling is crucial to cultivate the maximum irrigable area by ensuring equity among the farmers and to increase the water use efficiency and yield. In this study, the FAO single crop coefficient approach was adopted to estimate rice water requirements, which were subsequently used to suggest appropriate irrigation schedules based on the recommended field-scale rice cultivation practices. The study results would improve the irrigation system management in the study area by facilitating in regulating the canal water flows and releases according to suggested irrigation schedules that could lead to increased benefited area, yield, and water efficiency without straining the available water resources.

  • PDF

Variation of Filamentous Periphyton Chlorophyll-a in accordance with Water Velocity and Specific Surface Area of Media in Small Urban Stream (도시 소하천에서 유속, 비표면적에 따른 사상형 부착조류의 Chlorophyll-a 변화)

  • Ahn, Chang Hyuk;Joo, Jin Chul;Lee, Saeromi;Oh, Ju Hyun;Ahn, Hosang;Song, Ho Myeon
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.551-558
    • /
    • 2013
  • The feasibility of water supply as in-stream flow for Mangwall stream was analyzed in terms of water quality and cultivation periphyton using two different types of water resources (e.g., surface water and bank filtration from Han River basin) and three different types of media (e.g., tile, concrete and pebble). The concentrations of organic and inorganic contaminants from the bank filtration were lower than those from surface water by 17.5 - 55.0%. Using water samples collected from Mangwall stream, surface water, and bank filtration, chlorophyll-a, phaeopigment, and growth rate of periphyton were investigated. During 30 day incubation for each water sample, it was observed that filamentous cyanobacteria, Oscillatoriaceae, accounted for 98%, and water velocity of 5 cm/s was optimum for the in situ filamentous cyanobacteria growth. Also, it was deducted for water velocity and chl-a to have an inverse correlation. Meanwhile, the greater the specific surface area of media, the higher the concentration of chl-a. From these results, both water velocity and specific surface area of media should be considered as an combined parameter to deter the growth of filamentous cyanobacteria.

Area Effect on Galvanic Corrosion of Condenser Materials with Titanium Tubes in Nuclear Power Plants (Titanium 전열관을 사용하는 원전 복수기 재료의 Galvanic Corrosion에 미치는 면적의 영향)

  • Hwang, Seong-Sik;Kim, Joung-Soo;Kim, Uh-Chul
    • Nuclear Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.507-514
    • /
    • 1993
  • Titanium tubes have recently been used in condensers of nuclear power plants since titanium has very good corrosion resistance to seawater. However, when it is connected to Cu alloys as tube sheet materials and these Cu alloys are connected to carbon steels as water box materials, it makes significant galvanic corrosion on connected materials. It is expected from electrochemical tests that the corrosion rate of carbon steel will increase when it is galvanically coupled with Ti or Cu in sea water and the corrosion rate of Cu will increase when it is coupled with Ti, if this couple is exposed to sea water for a long time. It is also expected that the surface area ratios, R$_1$(surface area of carbon steel/surface area of Ti) and R$_2$(surface area of carbon steel/surface area of Cu) are very important for the galvanic corrosion of carbon steel and that these should not be kept to low values in order to minimize the galvanic corrosion on the carbon steel of the water box. Immersed galvanic corrosion tests show that the corrosion rate of carbon steel is 4.4 mpy when the ratio of surface area of Fe/ surface area of Al Brass is 1 while it is 570 mpy when this ratio is 10$^{-2}$ . The galvanic corrosion rate of this carbon steel is increased from 4.4 mpy to 13 mpy at this area ratio, 1, when this connected galvanic specimen is galvanically coupled with a Ti tube. This can be rationalized by the combined effects of R$_1$ and R$_2$ on the polarization curve.

  • PDF

A Study on the Appropriate Size of Large Rainwater Utilizing Facilities and Estimation of Agricultural Water Availability in Namwon eup, Jeju Island (제주도 남원읍지역 대용량 빗물이용시설의 적정규모 및 농업용수 공급 가능량 산정 연구)

  • Kim, Minchul;Park, Wonbae;Kang, Bongrae
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.1
    • /
    • pp.84-94
    • /
    • 2020
  • Jeju Island is seeking reliable ways to secure alternative water resources using rainwater in order to conserve and manage its groundwater as sustainable water resources. The purpose of this study is to investigate the rainwater storage capability of small-size storage facilities installed at farmhouses in Uigwi and Wimi of Namwon-eup region. The rainwater outflows from the storage facilities in rain events were analyzed. The appropriate size of rainwater utilizing facilities are suggested to be about 5,800 ㎥ in Uigwi area and 4,900 ㎥ in Wimi area based on the calculation from the rainfall frequency and runoff amounts. If those facilities are put into operation in Uigwi and Wimi area, it is estimated approximately 32.3 and 11.5% of total agricultural water can be supplied by the facilities. Wimi area showed low rainwater usage because of less number of facilities relative to the size of farm areas and less intensive underground water usage. It is analyzed that more than 55% of agricultural water can be supplied by rainwater if 70 facilities without the rainwater facilities are connected to the rainwater utilizing facilities.

Possible Formation Area of the Japan Sea Proper Water I. Subareas by the Polar Front (동해고유수의 생성가능해역 I. 극전선에 의한 해역구분)

  • 최용규;양성기
    • Journal of Environmental Science International
    • /
    • v.2 no.1
    • /
    • pp.27-42
    • /
    • 1993
  • Based on the Results of Marine Meteorological and Oceanographical Observations during 1966∼1987 and the Ten-day Marine Report during 1970∼1989 by Japan Meteorological Agency, the possible area where the Japan Sea Proper Water (JSPW) can be formed is investigated by analyzing the distribution of water types in the Japan Sea. The Japan Sea can be divided into three subareas of Northern Cold Water(NCW), Polar Front(PF) and Tsushima Warm Current (TWC) by the Polar Front identified by a 6℃ isothermal line at the sea surface in vinter. Mean position of the Polar Front is approximately parallel to the latitude 39∼40。N. The standard deviation of the Polar Front from the mean position of about 130km width is the smallest in the region between 136。E and 138。E where the Polar Front is very stable, because the branches of the Tsushima Current are converging in this region. However, standard deviations are about 180∼250km near the Korean peninsula and the Tsugaru Strait due to greater variability of warm currents. In the NCW area north of 40∼30。N and west of 138。E, the water types of the sea surface to the loom depth are similar to those of the JSPW. This fact indicates that the surface layer of the NCW area is the possible region of the JSPW formation in winter.

  • PDF

Improving water use efficiency in the Upper Central Irrigation Area in Thailand via soil moisture system and local water user training

  • Koontankulvong, Sucharit;Visessri, Supatra
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.8-12
    • /
    • 2022
  • Water loss is one of the typical but challenging problems in water management. To reduced water loss or increase water efficiency, the pilot projects were implemented in the TTD's irrigation area. Modern soil moisture technology and local level water user training were conducted together as a mean to achieve improved water efficiency. In terms of technology, soil moisture sensors and monitoring system were used to estimate crop water requirement to reduce unnecessary irrigation. This was found to save 16.47% of irrigated water and 25.20% of irrigation supply. Further improvement of water efficiency was gained by means of local level water user training in which stakeholders were engaged in the network of communications and co-planning. The lessons learnt from the TTD pilot project was translated into good water management practices at local level.

  • PDF

Water Quality of Agricultural Groundwater in Western Coast Area and Eastern Mountain Area of Jeollabuk-do (전라북도 서부 해안지역과 동부 산악지역 농업용 지하수 수질 평가)

  • Jo, Jae-Yeong
    • Journal of Applied Biological Chemistry
    • /
    • v.54 no.3
    • /
    • pp.218-224
    • /
    • 2011
  • This study was conducted to estimate the water quality of agricultural groundwater well located in Buan-gun, Jinan-gun, Sunchang-gun, and Jangsu-gun of Jeollabuk-do. The groundwater samples were collected at 328 sites (Buan-gun: 158, Jansu-gun: 45, Sunchang-gun: 32, Jinan-gun: 93, respectively). We measured 4 kinds of general contaminants (pH, $NO_3-N$, $Cl^-$, and COD) and 10 kinds of specific contaminants (Cd, As, $CN^-$, Hg, phenol, Pb, $Cr^{+6}$, organophosphorus, trichloroethylene, and tetrachloroethylene). Generally, the level of general contaminants and specific contaminants in the agricultural groundwater was suitable for water quality standard in all sites for agricultural irrigation water. Exceptionally, chloride concentrations were exceeded water quality standard of agricultural groundwater at some sites in western coast area of Jeollabuk-do. Although water quality standards in agricultural groundwater have been suitable, the water contaminants of agricultural groundwater in western coast area were gradually increased than eastern mountain area.

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.

Community Characteristics and Assessment of Water Quality Impact by Plants at Flooded Area (저수지역 식물의 군집특성 및 수질영향 평가)

  • Lee, Yosang;Kim, Hojoon;Jeong, Seon A
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.6
    • /
    • pp.407-415
    • /
    • 2006
  • This study carried out submerged area due to Dam construction in the near future. It includes species classification of plant, survey of community structure, examination of pollutant load and assessment of water quality impact. The vascular plants of this area are listed 224 taxa; 64 families, 168 genera, 193 species, 30 varieties and 1 form. This study area is classified into total 21 communities, most community was consist of grass vegetation. Among the communities, Erigeron annuus ($869,286m^2$, 22%) community was dominant and Erigeron annuus-Avena fatua comminity (16%) was subdominant until May, and then Erigeron canadensis community occupied most area to $1,774,985m^2$ (32%) from May to July. For the evaluation of water quality impact due to submerged macrophyte, nutrient release test was conducted both dead body macrophyte and living body macrophyte. The results of release test show that T-N is not released at dead body macrophyte, but it is released at living body macrophyte, especially living body Artemisia priceps var. orientalis shows 1.436mgN/g. At release test of dead body macrophyte, T-P release rate of Erigeron annuus shows 0.500mgP/g at the top of them and it also shows 0.436mgP/g at Erigeron annuus of living body macrophyte. T-N load of submerged macrophyte shows 0.76% by comparison of total load on watershed and T-P load of that shows 3.61%. In case of removal macrophyte for reduction of pollutant load in submerged area, T-N load of submerged macrophyte changes from 0.76% to 0.15% by comparison of total load on watershed and T-P load of that changes from 3.61% to 0.72%.