• Title/Summary/Keyword: Water Vapor

Search Result 1,651, Processing Time 0.03 seconds

Effect of Surface Finishing Materials on the Moisture Conditions in Concrete: Vapor and Water Permeability of Finishing Materials Under Changing Environmental Conditions

  • Ryu, Dong-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.83-90
    • /
    • 2008
  • Permeability to vapor and water among other performances required for finishing materials is dealt with in this study. The relative moisture content of concrete coated/covered with a finishing material was experimentally investigated while changing the environmental conditions including temperature, relative humidity, and rainfall. An organic paint (water-based urethane), organic synthetic resin emulsion-type film coating (film coating E), and inorganic porcelain tiles were selected as the finishing materials. When compared from the aspect of vapor and water permeability, the vapor permeability and water permeability of water-based urethane were high and low, respectively; those of film coating E were high and high, respectively; and those of porcelain tiles were low and low, respectively. This means that the moisture state of concrete structures is governed not only by the environmental conditions but also by the performance of finishing materials. It is therefore of paramount importance to appropriately select a finishing material to address the specific deteriorative factors involved in the concrete structure to be finished.

Analysis of the Relationship of Water Vapor with Precipitation for the Winter ESSAY (Experiment on Snow Storms At Yeongdong) Period (겨울철 ESSAY (Experiment on Snow Storms At Yeongdong) 기간 동안 수증기량과 강수량의 연관성 분석)

  • Ko, A-Reum;Kim, Byung-Gon;Eun, Seung-Hee;Park, Young-San;Choi, Byoung-Choel
    • Atmosphere
    • /
    • v.26 no.1
    • /
    • pp.19-33
    • /
    • 2016
  • Water vapor in the atmosphere is an important element that generates various meteorological phenomena and modifies a hydrological cycle. In general, the Yeongdong region has a lot of snow compared to the other regions in winter due to the complex topography and an adjacent East Sea. However, the phase change from water vapor to ice cloud and further snowfall has little been examined in detail. Therefore, in this study, we investigated phase change of liquid water in terms of a quantitative budget as well as time lag of water vapor conversion to snowfall in the ESSAY (Experiment on Snow Storms At Yeongdong) campaign that had been carried out from 2012 to 2015. First, we classified 3 distinctive synoptic patterns such as Low Crossing, Low Passing, and Stagnation. In general, the amount of water vapor of Low Crossing is highest, and Low Passing, Stagnation in order. The snowfall intensity of Stagnation is highest, whereas that of Low Crossing is the lowest, when a sharp increase in water vapor and accordingly a following increase in precipitation are shown with the remarkable time lag. Interestingly, the conversion rate of water vapor to snowfall seems to be higher (about 10%) in case of the Stagnation type in comparison with the other types at Bukgangneung, which appears to be attributable to significant cooling caused by cold surge in the lower atmosphere. Although the snowfall is generally preceded by an increase in water vapor, its amount converted into the snowfall is also controlled by the atmosphere condition such as temperature, super-saturation, etc. These results would be a fundamental resource for an improvement of snowfall forecast in the Yeongdong region and the successful experiment of weather modification in the near future.

Characteristics of Precipitable Water Vapor and Liquid Water Path by Microwave Radiometer (마이크로웨이브 라디오미터에서 관측된 가강수량 및 구름물량 특성 분석)

  • Yang, Ha-Young;Chang, Ki-Ho;Cha, Joo-Wan;Choi, Young-Jean;Ryu, Chan-Soo
    • Journal of the Korean earth science society
    • /
    • v.33 no.3
    • /
    • pp.233-241
    • /
    • 2012
  • Based on the observation of the microwave radiometers at Cheongju, Hapcheon and Daegwallyeong in Korea, the precipitable water vapor and liquid water path have been analyzed for spatio-temporal characteristics. The observed datas have been validated by comparing precipitable water vapor between the microwave radiometer and the radiosonde near the sites. It resulted in the correlation coefficient of more than 0.8 in all three sites. For three regions, the precipitable water vapor shows similar seasonal variation and diurnal cycle, and that amount of precipitable water vapor increases from around 1000 LST and has a maximum value at 1900 LST. On the other hand, the liquid water path of microwave radiometer has regional differences for its seasonal variation, which seems to be caused by the geographical characteristics including the frequent fog and clouds in Daegwallyeong, a high mountain region (834 m from sea level), almost flat land in Chengju, and Sobaek Mountains in Hapcheon that blocks the westerly clouds.

Effects of Water Vapor Concentration on a Droplet Evaporation (액적의 증발에 미치는 수증기 농도의 영향)

  • Kim, Y.W.;Lee, M.J.;Ha, J.Y.;Chung, S.S.
    • Journal of ILASS-Korea
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 1999
  • An experimental study has been conducted to clarify the effect of vapor on droplet evaporation. Droplets of water, ethanol, n-hexadecane and n-heptane were exposed in air stream. Temperature, pressure, and flow velocity in the ambient air are 470K, 1 atm, and 2m/s, respectively. Measurements are carried out for the wide range of water vapor concentration$(0%\sim40%)$. To obtain the time histories of droplet diameter, suspended droplet in hot and humid air stream was synchronized with a back flash light, and enlarged droplet images were taken on a CCD camera. With the vapor concentration increasing, the evaporation rate constant of water droplet decrease slightly and the droplet of ethanol and n-heptane increase actively. The evaporation rate constant of n-hexadecane which has higher boiling point than water increases within around 30% of the concentration.

  • PDF

Analysis of Falling-film Generator in Ammonia-water Absorption System (암모니아-물 흡수식 시스템에서 유하액막식 발생기의 해석)

  • 김병주;손병후;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.422-430
    • /
    • 2001
  • In the present study, an evaporative generation process of ammonia-water solution film on the vertical plate was analysed. For the utilization of waste heat, hot water of low temperature was used as the heat source. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. Counter-current solution-vapor flow resulted in the refrigerant vapor of the higher ammonia concentration than that of co-current flow. Eve the rectification of refrigerant vapor was observed near the inlet of solution film in counter-current flow. For the optimum operation of generator using hot water, numerical experiments, based on the heat exchange and generation efficiencies. revealed the inter-relationships among the Reynolds number of the solution film and hot water, and the length of generator. Enhancement of heat and mass transport in the solution film was found to be very effective for the improvement of generation performance, especially at high solution flow rate.

  • PDF

The estimation on the insulation performance of thermal insulation materials according to water vapor permeance (투습성에 따른 단열재의 단열성능평가 및 고찰)

  • Kim, Seok-Hyun;Park, Jong-Il;Lee, Min-Woo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1012-1018
    • /
    • 2006
  • In this study, the insulation performance of thermal insulation materials such as glass wool, polyetylene and flexible lastomeric foam according to water vapor permeance was estimated by using experimental correlation equation. The results showed the conductivity increment of flexible lastomeric foam which has very low-permeability (${\le}0.15[ng/{\cdot}s{\cdot}Pa]\;or\;{\mu}{\ge}1,000$) is about 50% lower than that of glass wool with the lapse of ten years. The conclusion is that moisture inevitably accumulated in permeable Insulations reduces insulation performance and also accelerates surface condensation in the case of cold water system.

  • PDF

Moisture Transport Observed by Water Vapor Isotopes in the Vicinity of Coastal Area, Incheon, Korea (수증기안정동위원소를 이용한 해안지역 수분의 이동경로에 관한 연구)

  • Lee, Jeonghoon;Choi, Heejin;Oh, Jinman;Na, Un-Sung;Kwak, Hoje;Hur, Soon Do
    • Economic and Environmental Geology
    • /
    • v.46 no.4
    • /
    • pp.339-344
    • /
    • 2013
  • Water vapor isotopes can be excellent tools for understanding complex mechanisms in the water cycle and atmospheric hydrological cycle and they can be applied to various fields of paleoclimatology, atmospheric science, hydrogeology, oceanography, and ecohydrology. Thus, studies of global or local transport of water vapor may be able to provide a very useful clue to better understand the movements of water and energy in the atmosphere, hydrosphere and biosphere. In this study, the isotopic compositions of water vapor have been observed for moisture transport during the passage of Typhoon Bolaven at Korea Polar Research Institute (KOPRI), Incheon, in the western part of Korea, from August 27 to August 29, 2012. In the clear sky, the isotopic compositions of water vapor at KOPRI exhibited relatively higher isotopic ratios, which were near isotopic equilibrium with sea surface water (${\delta}^{18}O$=-14‰). On the other hand, a largely depleted isotopic ratios in surface water vapor were observed in association with the passage of Typhoon Bolaven (approximately 10‰ depleted compared to the clear sky). The fact that the isotopic minima in water vapor are encountered during the onset period of the Typhoon Bolaven with increases of relative humidity, which is consistent with, so called, "the amount effect".

An Experimental Study on the Performance of a Liquid-Vapor Ejector with Water (액체-증기 이젝터의 성능에 관한 실험적 연구)

  • 박대웅;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.345-353
    • /
    • 2000
  • In this study, the performance of five ejectors has been investigated with working fluids of water and water vapor. The diameters of nozzle and mixing tube of five ejectors were 1 and 1.5(ejector A), 1 and 2(ejector B), 1 and 2.5(ejector C), 1 and 3(ejector D), 2 and 4(ejector E) in millimeters. The length of the mixing tube was 8-10 times of its diameter. For each ejector, the ratio of mass flow rate of ejected water to that of entrained water vapor, $\mu$, was evaluated in terms of evaporator pressure, mass flow rate of ejected water, and water temperature. It was found that the performance of an ejector was not stable when the ratio of diameters was too small or too large(ejector A and D) and $\mu$ was almost the same for two ejectors with the same diameter ratio(ejector B and E). It was also found that $\mu$ increased almost linearly with an increase of evaporator pressure and the ratio $\mu$ increased as water temperature decreased. As expected, $\mu$ converged to zero as the water temperature approached the evaporator temperature. Finally, a non-dimensional correlation has been developed to predict$\mu$ terms of evaporator pressure and saturation pressure of ejected water.

  • PDF

Influence of Surface Heterogeneity on Turbulent Transfer in the Surface Layer (지표면의 비균질성이 지표층의 난류수송에 미치는 영향)

  • Hong, Seon-Ok;Lee, Young-Hee;Lim, Yoon-Jin
    • Atmosphere
    • /
    • v.24 no.3
    • /
    • pp.317-329
    • /
    • 2014
  • Eddy covariance data have been analyzed to investigate the influence of surface heterogeneity on turbulent transfer over farmland and industrial sites near Nakdong river, Korea, where both large and small scale heterogeneities co-exist. For this purpose, basic turbulent statistics, quadrant analysis and multi-resolution decomposition have been analyzed during the daytime. Basic turbulent statistics were compared with typical turbulent statistics in the surface layer. Such comparisons were in close agreement for momentum and heat at both sites but not for water vapor at industrial site. The correlation coefficient between water vapor and vertical velocity ($r_{wq}$) is relatively low and skewness of water vapor ($sk_q$) is very low at industrial site, possibly due to limited water source. For heat at both sites and water vapor at farmland, the quadrant analysis show similar behavior to that over homogeneous site but for water vapor at industrial site, the presence of river and limited water source at industrial site seems to influence on water vapor transfer by coherent eddy motion by increasing sweep contribution and decreasing ejection contribution. Multi-resolution decomposition analysis shows that large scale heterogeneity leads to low $r_{Tq}$ at large averaging time regardless of season at both sites and there are seasonal changes of $r_{Tq}$ in mid-averaging times at industrial site, possibly due to seasonal change of trees and grasses near the site.

Vapor Sorption Property of Charcoal-based Loess Composites (숯과 황토 복합소재의 흡착성능)

  • Lee, Won-Hee
    • Journal of the Korea Furniture Society
    • /
    • v.17 no.3
    • /
    • pp.87-94
    • /
    • 2006
  • The purpose of this study was to evaluate the relationships between the mixing ratio and water vapor sorption property of charcoal-based loess composites for furniture & building materials with environmental friendly. Charcoal-based loess composite can be easily made by blending method with water. But the composites had much brittle fracture pattern with the increase of charcoal content. That is due to the lack of loess that takes linkage role of composites. In water vapor sorption properties, adsorption ability of charcoal was about six times higher than that of loess. Therefore, vapor sorption ability was maximum at the mixture ratio of charcoal 80% and loess 20%. It is considered that wood charcoal based inorganic composite materials can be used for various purposes as a building interior & exterior and furniture members.

  • PDF