• Title/Summary/Keyword: Water Vapor

Search Result 1,656, Processing Time 0.029 seconds

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.

A study on the development of the high efficiency condensing heat exchanger (고효율 응축형 열교환기 개발에 관한 연구)

  • Lee, Geum-Bae;Park, Sang-Il;Park, Jun-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

Absorption of Water Vapor into an Absorbing Binary Liquid Film Falling over a Horizontal Tube Bank (수평원관군상(水平圓管群上)의 이원흡수용액유동(二元吸收溶液流動)에 의(依)한 전달흡수특성(傳達吸收特性))

  • Kim, S.;Kim, Y.I.;Seo, S.C.;Hwang, D.K.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.5
    • /
    • pp.583-589
    • /
    • 1988
  • Condensation of water vapor into an absorbent liquid of LiBr-water solution falling over a bank of water cooled horizontal tubes was investigated theoretically. The governing conservation equation for a re-defined physical transport phenomena were solved numerically using a finite difference method. Raw parameters were used in this study, since reliable experimental data is required prior to a dimensionless parametric study. The average values of wall heat transfer coefficient and interfacial absorption rate were defined to see the system performance. Other parameters include tube diameter, streamwise coordinate (and number of tubes in row), mass flow rate, and the wall temperature. The effects of these quantities on the absorption processes and suggestions for a rational system design have been presented.

  • PDF

The Correlation Study on the Desorption Enthalpy Changes of Sun- Cured Tobacco (향끽미종 잎담배의 탈착 엔탈피 변화에 관한 상관성 연구)

  • 최승찬
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.6 no.1
    • /
    • pp.33-37
    • /
    • 1984
  • The net enthalpy changes for the water desorption of sun-cured tobacco have been studied. In order to compare the values of net enthalpy changes for the samples at the same moisture contents, correlation analyses have been performed. The results are summarizing as followings : 1 . As temperature and water vapor pressure increased, equlibrium moisture content were approaching to the saturated vapor pressure of water. 2. The values of 1nP against the reciprocal of absolute temperature were linear for the water desorption of samples. 3. Multiple regression was analyzed to calculate the values of 1nP at the same moisture content. The significance of $x^2$-test for the multiple regression was 0.5%. 4. The values of net enthalpy changes for Basma were greater than those of Sohyang at the same moisture content.

  • PDF

Development of Raman Laser Radar System for Aerosol and Water Vapor Measurements (에어로졸, 수증기 측정 라만 레이저 레이다 시스템 개발)

  • Park, Chan-Bong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.158-161
    • /
    • 2012
  • Raman Laser Radar system for the measurements of aerosol and water vapor concentration is developed. As a transmitting system, Nd:YAG laser with 3rd harmonic Generator and beam expander are used. The wavelength of transmitting laser is 355 nm. The receiving system is consists of 500 mm telescope, 3-channel Raman spectrometer, PMT, and signal processing module. The wavelengths of received signals are 355 nm. 387 nm, and 408 nm 이다. The measurable altitude of this system is about 3~4 km with spatial resolution of 100~200 m.

  • PDF

Pecipitable Water Vapor Change Obtained From GPS Data

  • Kingpaiboon, Sununtha;Satomura, Mikio;Horikawa, Mayumi;Nakaegawa, Tosiyuki;Shimada, Seiichi
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.384-386
    • /
    • 2003
  • GPS observation has been performed at Khon Kaen in northeast Thailand to investigate the Precipitable Water Vapor (PWV) change since August 2001 by using a Trimble 4000SSi receiver. The data obtained in the period from March to June in 2002 were processed by using CAMIT software to obtain the Zenith Tropospheric Delay (ZTD) at every one hour referring to some IGS stations around Thailand. We estimated the Zenith Hydrostatic Delay (ZHD) at every three hours with barometer data at Khon Kaen of Thai Meteorological Department, The Zenith Wet Delay (ZWD) was obtained by subtracting ZHD from ZTD and PWV can be calculated from ZTD. The results obtained shows that PWV changes with a large amplitude in March and April before the monsoon onset, and also we can see steep PWV increases before rain and decreases after rain. In May and June after the onset, the PWV is almost constant to be 60 to 70 mm, but there is a semi-diurnal change which has high PWV values at about 8 and 20 o'clock in local time.

  • PDF

Comparative evaluation of water vapor transmission rate of PVA/Dextran blended hydrogel using European Pharmacopiea and Japanese Industrial Standards method (유럽 약전과 일본 산업기준 규격 방식에 의한 폴리비닐 알코올 및 덱스트란 함유 하이드로겔의 투습률 비교평가)

  • Choi, Han-Gon;Hwang, Ma-Ro;Oh, Dong-Hoon;Li, Dong-Xun;Kim, Jong-Oh;Lee, Jeong-Hoon;Woo, Jong-Soo;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.2
    • /
    • pp.93-95
    • /
    • 2009
  • To compare the water vapor transmission rate (WVTR) of PVA/Dextran blended hydrogel obtained by European Pharmacopiea (EP) and Japanese Industrial Standards 1099 (JIS) method, the hydrogels with various PVA/Dextran rates were prepared and their WVTR values were then checked. As dextran in the hydrogel was increased, the WVTR of hydrogel was increased. The WVTR of hydrogels were 660-1500 and $730-1900\;g/m^2$-day in EP and JIS method, respectively. There were no significant differences between the WVTRs of the hydrogels obtained by EP and those obtained by JIS method. Thus, JIS method was recommended as a WVTR method of hydrogel due to relatively simpler and shorter time.

Analysis of Radiosonde Daily Bias by Comparing Precipitable Water Vapor Obtained from Global Positioning System and Radiosonde

  • Park, Chang-Geun;Cho, Jung-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.367-375
    • /
    • 2010
  • In this study, we compared the precipitable water vapor (PWV) data derived from the radiosonde observation data at Sokcho Observatory and the PWV data at Sokcho Global Positioning System (GPS) Observatory provided by Korea Astronomy and Space Science Institute, from 0000 UTC, June 1, 2007 to 1200 UTC, May 31, 2009, and analyzed the radiosonde bias between the day and the night. In the scatter diagram of the daytime and nighttime radiosonde PWV data and the GPS PWV data, dry bias was found in the daytime radiosonde observation as known in the previous study. In addition, for all the rainfall events, the tendency that the wet bias of the radiosonde PWV increased as the GPS PWV decreased and the dry bias of the radiosonde PWV increased as the GPS PWV increased was significantly less distinctive in nighttime than in daytime. The quantitative analysis of the bias and error of the radiosonde PWV data showed that the mean bias decreased in the second year, regardless of nighttime or daytime rainfall, and the non-rainfall root mean square error (RMSE) was similar to that of the previous studies, while the rainfall RMSE was larger to a certain extent.

Layer-by-layer assembled graphene oxide films and barrier properties of thermally reduced graphene oxide membranes

  • Kim, Seon-Guk;Park, Ok-Kyung;Lee, Joong Hee;Ku, Bon-Cheol
    • Carbon letters
    • /
    • v.14 no.4
    • /
    • pp.247-250
    • /
    • 2013
  • In this study, we present a facile method of fabricating graphene oxide (GO) films on the surface of polyimide (PI) via layer-by-layer (LBL) assembly of charged GO. The positively charged amino-phenyl functionalized GO (APGO) is alternatively complexed with the negatively charged GO through an electrostatic LBL assembly process. Furthermore, we investigated the water vapor transmission rate and oxygen transmission rate of the prepared (reduced GO $[rGO]/rAPGO)_{10}$ deposited PI film (rGO/rAPGO/PI) and pure PI film. The water vapor transmission rate of the GO and APGO-coated PI composite film was increased due to the intrinsically hydrophilic property of the charged composite films. However, the oxygen transmission rate was decreased from 220 to 78 $cm^3/m^2{\cdot}day{\cdot}atm$, due to the barrier effect of the graphene films on the PI surface. Since the proposed method allows for large-scale production of graphene films, it is considered to have potential for utilization in various applications.

Electrical Conduction in $SrZr_{0.95}Y_{0.05}O_{2.975}$ Ceramics

  • Baek, Hyun-Deok;Noh, Jin-Hyo
    • The Korean Journal of Ceramics
    • /
    • v.5 no.3
    • /
    • pp.288-295
    • /
    • 1999
  • Partial conductivities contributed by electron holes, oxygen ions, and protons were caluclated in $SrZr_{0.95}Y_{0.05}O_{2.975}$, using the reported formulae derived from the defect chemistry of HTPCs. Required parameters were obtained from the graphical analysis of total conductivity variation against partial pressure of water vapor and oxygen. Predicted overall conductivities showed a reasonable agreement with experimental measurements. The conductivity of the material showed a linear increase with square root of the water vapor pressure. This increase was due to proton conduction in an almost pure ionic conductivity. The calculation of partial conductivities at $800^{\circ}C$ resulted in an almost pure ionic conductivity at $P_{02}=10^{-10}$ atm and a predominant hole conductivity at $P_{02}=10^{-10}$ atm. Pure proton conduction was not expected at this temperature, contrary to the earlier reports. Discussions were made in relation with reported thermodynamic data and defect structure of the material. It was shown that from the total conductivity dependence on water vapor pressure, the pure ionic conductivity at low oxygen partial pressures could be separated into protonic and oxygen ionic conductivity in $ZrO_2$-based HTPCs.

  • PDF