• Title/Summary/Keyword: Water Saving Volume

Search Result 31, Processing Time 0.024 seconds

Water saving irrigation method in paddy fields (용수절약형 논관개 기법(관개배수 \circled1))

  • 정상옥;안태홍
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.108-113
    • /
    • 2000
  • A field study was performed to investigate the effect of water saving irrigation method on water use efficiency and rice yield. The field plot was 40a (40 ${\times}$ 100m) in size and located at Buryangmyun, Kimjae city, Chonbuk province. Field measurements were made during the growing seasons, May to September of the year 1998 and 1990. Irrigation water volume, drainage water volume, rainfall and ponding depth were measured. Irrigation water management practice employed was such that to keep the ponding depth about 3 to 4cm by intermittent irrigation with drying the soil surface until hair cracks emerge before the next irrigation. The amounts of water volume irrigated and drained were measured by pipe flow meter and ponding depth was observed by using a partly buried 120mm diameter PVC pipe. The results showed that the irrigation water depths, the rainfalls, and the drainage depths were 379mm, 458mm, and 448mm in 1988, and 274mm, 819mm, and 736mm in 1990, respectively. The average yield was 590kg per 10a. The water saving irrigation method saved irrigation water by about 20% with higher yield compared with the traditional method.

  • PDF

A Study of Water Budget Analysis According to The Water Demand Management (수요관리에 의한 물수급변화 분석)

  • Seo, Jae-Seung;Lee, Dong-Ryul;Choi, Si-Jung;Kang, Seong-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.797-803
    • /
    • 2011
  • In this study, we developed the assessment method that evaluate the water demand management and calculate the water saving volume using water use indicator, and developed the system to link the water saving volume that occur through demand management and water supply and demand. The results from this study, local governments with poor water conditions should be followed to improve the water supply. And, future water demand estimates should be even considering it. We calculated the water saving volume of the Geum River basin using K-WEAP (Korea-Water Evaluation And Planning System) and performed the water budget analysis. We found that the change of river flow, ground water level and reservoir water level, and it can be utilized for other demand.

Study on Utilizing Resources in Environment-friendly City - Operation method of rain storage tank for using rainwater as multipurpose - (친환경 도시에서의 자원활용에 관한 연구 -빗물의 다목적 활용을 위한 빗물저장조의 운전방법 -)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.3
    • /
    • pp.359-366
    • /
    • 2003
  • Ecological society and energy conservative systems has become a subject of world wide attention. To examine the technologies of such systems as resource recycling society, this study is proposed for using rainwater as energy source and water resources in urban area. Useful informations for planning of utilizing rainfall as energy source, water resources, emergency water and controlling flood are discussed with model systems in urban area. It is calculated that the rate of utilizing rainwater, amounts of utilizing rainwater, substitution rate of supply water, amounts of overflow rainwater according to rain storage tank volume. By applying the past weather data, The optimum volume of rain water storage was calculated as 200m$^3$ which mean no benefits according to the increase of storage tank volumes. For optimum planing and control method at the model system, several running method of rainwater storage tank was calculated. The optimum operating method was the using weather data as 3hours weather forecast.

A Water-saving Irrigation Decision-making Model for Greenhouse Tomatoes based on Genetic Optimization T-S Fuzzy Neural Network

  • Chen, Zhili;Zhao, Chunjiang;Wu, Huarui;Miao, Yisheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.6
    • /
    • pp.2925-2948
    • /
    • 2019
  • In order to improve the utilization of irrigation water resources of greenhouse tomatoes, a water-saving irrigation decision-making model based on genetic optimization T-S fuzzy neural network is proposed in this paper. The main work are as follows: Firstly, the traditional genetic algorithm is optimized by introducing the constraint operator and update operator of the Krill herd (KH) algorithm. Secondly, the weights and thresholds of T-S fuzzy neural network are optimized by using the improved genetic algorithm. Finally, on the basis of the real data set, the genetic optimization T-S fuzzy neural network is used to simulate and predict the irrigation volume for greenhouse tomatoes. The performance of the genetic algorithm improved T-S fuzzy neural network (GA-TSFNN), the traditional T-S fuzzy neural network algorithm (TSFNN), BP neural network algorithm(BPNN) and the genetic algorithm improved BP neural network algorithm (GA-BPNN) is compared by simulation. The simulation experiment results show that compared with the TSFNN, BPNN and the GA-BPNN, the error of the GA-TSFNN between the predicted value and the actual value of the irrigation volume is smaller, and the proposed method has a better prediction effect. This paper provides new ideas for the water-saving irrigation decision in greenhouse tomatoes.

Energy-Saving and Environmental Evaluation of Water Supply System on Replacing Water Storage Installed Booster Pump System by Direct Connecting Booster Pump System (저수조 설치 펌프직송방식의 수도직결 증압방식 전환에 관한 에너지절약성 및 환경성 검토)

  • Lee, Chulgoo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.3
    • /
    • pp.7-12
    • /
    • 2015
  • Currently water supply system with water storage is generally applied except for small building such as single-family houses, and water supply system on replacing water storage installed system by direct connecting system has been increasing because of sanitary and energy-saving aspects. The purpose of this study is to evaluate energy-saving and environmental efficiency of direct connecting booster pump system in comparison with the water storage installed system. The architectural condition of the evaluation subject is ten-story apartment house in which sixty households live. To calculate the power consumption of the pump, the volume of water supply was determined from existing data and other data, such as head, efficiency of the pump, was the value used for general application in design office. The power consumption of the water supply pump for one day was 8.5 kWh for direct connecting booster pump system, and 22.5 kWh for water storage installed system, and the former system showed energy savings of 62% compared to the latter system. Reduced power consumption also leads to reduction of $CO_2$ emission. According to the criteria presented in the Korea Energy Management Corporation, reducing the 2,410 kg $CO_2$ emission is possible per year.

A Study on Development of High Efficiency Toilets with VOF Numerical Analysis (VOF 수치해석을 통한 고절수형 위생도기 개발에 관한 연구)

  • An, Il Yong;Lee, Young Lim;Jo, Woo Suck;Kim, Jin Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.946-953
    • /
    • 2012
  • When water shortage has been getting worse recently, toilet water-saving is one of the most effective way to solve the water shortage. Therefore, in this study, toilet flushing performance was investigated with VOF(Volume Of Fluid) model to obtain the basic design data for the development of high-efficiency toilets. The result showed that the shorter trapway, the longer the flushing duration time. However, the shorter trapway is found to have disadvantage in exhausting dirt due to relatively weak siphon and higher curvature. Since the remaining water in a trapway appears to help siphon, it is also an important factor in developing high-efficiency toilets. Although higher water level in the water tank shows better performance in flushing, lower water level is preferred to save water. Too low water level may cause dirt to clog the trapway due to relatively weak siphon.

Energy Simulation for Energy Saving Opportunities

  • Lee, E.J.;J.H. Yoon;Y.H. Kang;H.S. Jeon
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.88-93
    • /
    • 1995
  • The purpose of this study is to introduce the energy simulation program BLDSYM, verify the approach. and demonstrate the energy saving opportunities. A case study model for Hoover Middle School, OK USA has been introduced as a base case simulation. Air-side variable air volume (VAV) and water-side variable flow hydronic (VFH) system have been recommended, modeled and simulated to quantify the energy savings compared with the base system, which is typically constant air and water flow system. More than 30 % of energy savings could be obtained with the optimum variable flow system.

  • PDF

A study of the performance on large capacity screw compressors (중대형 스크루 압축기의 성능에 관한 연구)

  • Park, D.S.;Yang, S.H.;Lee, D.J.;Shin, J.K.;Yoo, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.668-671
    • /
    • 2001
  • For the saving of energy consumption, it is necessary that the high efficient energy transfer machine. We found the optimum operating condition of screw water chiller during this performance test. The specifications of compressor for this performance test are as follows. Built-in volume ratio; Vi=2.4, using refrigerant; HCFC-22, nominal motor output; 60kW(80Hp). We found the test results on water cooled chiller standard test condition that the evaporating capacity is increased 8% maximum and 5.6% under same operating condition. and COP is increased 11 % max. and 8% under same operating condition with change of the evaporating inlet/outlet condition. For the results of these test, we can estimate the optimum operating condition of water cooled type screw chiller.

  • PDF

A Study on The New Conceptual Faucet Design to Which Flow-meter is attached (유량 측정기기 부착 수전금구 디자인에 관한 연구)

  • 박성룡
    • Archives of design research
    • /
    • v.17 no.2
    • /
    • pp.351-362
    • /
    • 2004
  • Generally, they respond to a phenomenon, with their any way, which they have looked at in their surroundings, and also put into their action successively and variously according as what it is. A person who has not so much problems in experiential education added to mental and physical ability prefers controlling his manner by himself as seeing, listening and feeling to being cured it by other physical support. Meanwhile, even though there are tools that we use conveniently in everyday life, it is sometimes required that user is able to control his action by himself with a certain interactive function to deal with a accidental situation. For example, in the home, when they were cooking, washing dishes and taking a bath they would not often control their minds on how to act about flowing water through the faucet going back and forth between saving and easygoing. By reasons of those statements, the project has been studied to propose the new conceptual faucet which digital technology is applied to, for recognizing the volume of water flowed through water pipe as counting it with built-in flow meter, and then saving water as controling the water-flow with faucet lever. It means that homemakers can observe the flow rate of water from the faucet placed in front of the sink in kitchen and control it right away for saving water. For studying this project, the kinds and features of the various flow-meters that measure the volume of water-flow were researched and analyzed for taking a reasonable type to the new ideal faucet. According to this analyzing, turbine-flow-meter was selected as appropriate form for the digital display-built-in faucet that would be presented in this project. As the next step, the basic structure was created for developing a new conceptual faucet. Finally two models have been presented through several steps for making the suitable shape to the new style faucet.

  • PDF

Effects of the Air Volume in the Air Chamber on the Performance of Water Hammer Pump System

  • Saito, Sumio;Takahashi, Masaaki;Nagata, Yoshimi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.2
    • /
    • pp.255-261
    • /
    • 2011
  • Recently, as global-scale problems, such as global warming and energy depletion, have attracted attention, the importance of future environmental preservation has been emphasized worldwide, and various measures have been proposed and implemented. This study focuses on water hammer pumps that can effectively use the water hammer phenomenon and allow fluid transport without drive sources, such as electric motors. An understanding of operating conditions of water hammer pumps and an evaluation of their basic hydrodynamic characteristics are significant for determining whether they can be widely used as an energy-saving device in the future. However, conventional studies have not described the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. As a first stage for the understanding of water hammer pump performance in comparison to the characteristics of typical turbo pumps, the previous study focused on understanding the basic hydrodynamic characteristics of water hammer pumps and experimentally examined how the hydrodynamic characteristics were affected by the inner diameters of the drive and lift pipes and the angle of the drive pipe. This paper suggests the effect of the air volume in the air chamber that affects the hydrodynamic characteristics and operating conditions of the water hammer pump.