• Title/Summary/Keyword: Water Pressure

Search Result 6,417, Processing Time 0.034 seconds

Experimental Study on Transformation of IPF and Pressure Drop in Branches with Ice Slurry (아이스슬러리의 분기관내 압력손실과 IPF 변화에 관한 실험적 연구)

  • 박기원;최현웅;노건상;정재천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.272-279
    • /
    • 2003
  • This study aimed to understand the effects of transporting ice slurry Particles through Pipes with branches. The experimental apparatus was constructed as ice slurry mixing tank. vortex pump, manometers for differential pressure measuring. IPF(ice packing factor) measuring instruments and branches as test sections. The experiments were carried out under various conditions. with concentration of water solution ranging between 0∼20wt% and velocity of water solution at the entry ranging between 1.5∼2.5m/s. The differential Pressure and IPF between the pipe entry and exit were measured. and flowing form was checked throughout the experiment. The pressure loss in 3d branches appeared compared with 6d branches so that it was very high. In the pressure loss of the inside and outside of branches. 6d branches was showed the difference. but was agreed in 3d branches The pressure loss according to concentration of water solution, low value appeared at 10wt% in 6d branches, at 20wt% in 3d branches. The pressure loss according to velocity, did not show large difference. The change of IPF at outlet, appeared +15∼-25% in 6d branches and 0∼-20% in 3d branches. The difference of IPF at the inside and outside of branches. appeared 10∼15% in 6d branches and maximum 5% in 3d branches.

Analysis of hydraulic system for seawater desalination plant through piping analysis program (배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석)

  • Choi, Jihyeok;Choi, Yongjun;Yang, Heungsik;Lee, Sangho;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

Hydrostatic Pressure Resistance Performance Testing of Cement Mixed Siliceous Powder Waterproofing Coationgs (규산질계 분말형 도포방수재의 내투수성 성능평가 연구)

  • Park, So-Young;Kwon, Si-Won;Kim, Soo-Yeon;Kim, Byong-il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.31-32
    • /
    • 2018
  • Lately, cement mixed siliceous powder waterproofing coating has been used as a waterproofing material in the wet environment condition of an underground concrete structure. Underground is exposed to environmental influences such as pressure of ground water, pressure of soil. However, the quality standard for pressure (water pressure, earth pressure) is not specified in the specification of the cement mixed siliceous powder waterproofing coating. Therefore, in this study, the permeability test was carried out based on the assumption that the durability should be verified in consideration of the environmental aspects of the material in actual field. As a result of the test, the permeability was generated from the inorganic single type material, but it was caused by the sealing failure and the test error, and the permeability was not generated in most of the materials. The results of this study will be analyzed by reviewing the physical properties of the material, and the research direction will be resumed.

  • PDF

STORAGE OF BROCCOLI BY MAKING THE WATER STRUCTURED -Suppression of metabolism-

  • Oshita, S.;Seo, Y.;Kawagoe, Y.;Rahman, M.A.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.918-925
    • /
    • 1996
  • The effect of structured water by dissolution of xenon was examined from the view point of the suppression of both browning and respiratory metabolism of broccoli. The structured water is formed duet to hydrophobic interaction when xenon gas dissolves into water. NMR measurements were carried out to determine proton spin-spin relaxation time, T2, for water. There was a difference in proton T2 between distilled water and structured water. This can be interpreted as the change of water structure. Fro the broccoli cut in half stored for 16 days at 279K, the section color did not change appreciably for the sample whose water was structured by dissolution of xenon whose initial partial pressure was 0.39MPa. In contrast to this, the browning of section surface was observed for the sample stored under the condition of nitrogen gas at the same partial pressure as xenon and for the sample stored under atmospheric condition . These results led to the conclusion that the suppression of b owning by oxidation was due to structured water but not to applied pressure. Adding to this, the water structured by xenon has resulted in suppression of respiratory metabolism of broccoli.

  • PDF

A Study on the Water Relation Characteristics of the Soybean Shoots through the Pressure Chamber Technique (Pressure Chamber Technique에 의한 대두경엽의 수분특성 연구)

  • E-Hun Kim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.28 no.1
    • /
    • pp.128-132
    • /
    • 1983
  • The water relations parameters such as original osmotic pressure $(\Pi_0)$, osmotic pressure $(\Pi_p)$, at the incipient plasmolysis, the volume of osmotic water $(V_o)$ at the full turgor, the relative water content $(RWC^*)$ at the incipient plasmolysis, the volume of osmotic water$(V_p)$ at the incipient plasmolysis, the volume of symplasmic and apoplastic water$(w_s)$ at the maximum turgor, $V_pV_o, \; V_oW_s, \; W_sD_w, \; V_oF_w$ and the elastic modulus were measured through the pressure chamber (DIK-PC-40 Model) technique with the Williams and Geumgangdaerip soybean cultivar shoots. The original osmotic pressure$(\P $i_{0}$ )$, of the both cultivars shoots were appeared insignificant differences as 8.1 bar and 7.8 bar respectively. The osmotic pressure($\pi$$_{p}$ ) at the incipient plasmolysis was 9.0 bar in Williams and 10.4 bar in Geumgangdaerip. The relative water content(RW $C^{*}$) at the incipient plasmolysis was 86.0 per cent in Geumgangdaerip and 92.6 per cent in Williams. The ratio of volume of osmotic water( $V_{p}$ ) at the incipient plasmolysis to total symplasmic water$(V_o)$ , i.e., $V_p/V_o$ was 83.4 per cent in Geumgangdaerip and 90.4 per cent in Williams. The elastic modulus of Geumgangdaerip shoots showed higher value than Williams$(8.5 $\times$ 10^2bar)$ as $1.6 \times10^5$ bar.r.

  • PDF

An Experimental Study of the Effects of Water Vapor in Intake Air on Comvustion and knock Characteristics in a Spark Ignition Engine (흡기중 수증기 함량이 스파크 점화기관의 연소 및 노킹에 미치는 영향에 관한 실험적 연구)

  • 이택헌;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.205-212
    • /
    • 1998
  • In this study, the effects of water vapor in inlet air on combustion efficiency, general performance, knock characteristics and emission gas concentration were investig- ated through the experiments of combustion and vibration analyses, emission gas analysis by changing water vapor quantity in inlet air with temperature and humidity auto control unit. With partial vapor pressure increase, the brake torque at wide open throttle status decreased and the average ignition delay angle increased, IMEP (indicated mean effective pressured using the integral and 3rd derivatives of filtered cylinder pressure as knock intensity, which matched well with the method of frequency power spectrum of block vibration signal. Water vapor in intake air had influence on the spark knock sensitivity. With the increase of water vapor content in intake air NOx emission was decreased and HC emission was increased.

  • PDF

Prediction of Water Penetration and Diffusion in Concrete Through FEM Analysis (FEM해석을 통한 콘크리트내 수분침투 및 확산 예측)

  • Yoo, Jo-Hyeong;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.87-88
    • /
    • 2010
  • A permeability of concrete is a very important factors evaluating durability. So, we are carrying out a lot of relational data bases and experiment regarding a permeability. In order to evaluate a permeability of concrete, we are proceeding study on the water penetration and diffusion in concrete by water pressure. Because a way to evaluate a permeability of concrete has a limit. We will present a good method of evaluating durability of concrete using the water penetration depth of concrete by water pressure. To carry this out, we executed experiment with penetration depth of concrete by water pressure and verified it though FEM analysis.

  • PDF

Study on Constructibility considering Changes of Groundwater Level in Kwang Yang port (광양지역 지하수위 변화를 고려한 시공성에 관한 연구)

  • Kim, Byeong-Ho;Yang, Tae-Seon;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1120-1125
    • /
    • 2006
  • Larger area will be constructed in a harbor land and container terminal which are constructed in reclaimed land using the dredged materials. Soil improvement work is to be carried out including constructibility, in which is monitoring devices, measuring frequency, installations etc. The ground water tables in the reclaimed area are affected by the several factors which are design reclamation level, consolidation settlement, remaining surcharge pressure and remaining excess pore water pressure. The plan wii be drawn up in which monitoring results for the ground water tables are capable to provide the reliable ground water table when designers and civil engineers construct the harbor structures considering constructibility.

  • PDF

A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System (실별제어 온수분배기의 유량분배 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.