• 제목/요약/키워드: Water Level Monitoring

검색결과 647건 처리시간 0.027초

Understanding Hydrogeologic Characteristics of a Well Field of Pyosun in Jeju Volcanic Island of Korea

  • Lee, Jin-Yong;Lee, Gyu-Sang;Song, Sung-Ho
    • 한국지구과학회지
    • /
    • 제29권5호
    • /
    • pp.396-407
    • /
    • 2008
  • Hydrogeologic properties of a well field around middle mountainous areas in Pyosun, Jeju volcanic island were examined based on water level monitoring, geologic logging and pumping test data. Due to the alternating basaltic layers with varying permeability in the subsurface, it is difficult to analyze the hydraulic responses to artificial pumping and/or natural precipitation. The least permeable layer, detrital materials with clay, is found at a depth of 200 m below surface, but it is not an upper confining bed for lower main aquifer. Nevertheless, this layer may serve as a natural barrier to vertical percolation and to contaminant migration. Water levels of the production wells are dominantly affected by pumping frequently, while those of the remote observation wells are controlled by ambient precipitation. Results of pumping tests revealed a possible existence of horizontal anisotropy of transmissivity. However, some results of this study include inherent limitations enforced by field conditions such as the consistent of groundwater production and the set of time periods for the cessation of the pumping prior to pumping tests.

모터펌프의 지능형 진단시스템 구현에 관한 연구 (A Study on the Implementation of Intelligent Diagnosis System for Motor Pump)

  • 안재현;양오
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.87-91
    • /
    • 2019
  • The diagnosis of the failure for the existing electrical facilities was based on regular preventive maintenance, but this preventive maintenance was limited in preventing a lot of cost loss and sudden system failure. To overcome these shortcomings, fault prediction and diagnostic techniques are critical to increasing system reliability by monitoring electrical installations in real time and detecting abnormal conditions in the facility early. As the performance and quality deterioration problem occurs frequently due to the increase in the number of users of the motor pump, the purpose is to build an intelligent control system that can control the motor pump to maximize the performance and to improve the quality and reliability. To this end, a vibration sensor, temperature sensor, pressure sensor, and low water level sensor are used to detect vibrations, temperatures, pressures, and low water levels that can occur in the motor pump, and to build a system that can identify and diagnose information to users in real time.

Microbial Risk Assessment using E. coli in UV Disinfected Wastewater Irrigation on Paddy

  • Rhee, Han-Pil;Yoon, Chun-G.;Jung, Kwang-Wook;Son, Jang-Won
    • Environmental Engineering Research
    • /
    • 제14권2호
    • /
    • pp.120-125
    • /
    • 2009
  • Water stress has become a major concern in agriculture. Korea suffers from limited agricultural water supply, and wastewater reuse has been recommended as an alternative solution.A study was performed to examine the effects of microorganism concentration in the ponded-water of a paddy rice field with reclaimed-water irrigation for evaluating the microbial risk to farmers and neighborhoodchildren.Most epidemiological studies were performed based on an upland field, and they may not directly applicable to paddy fields. Beta-Poisson model was used to estimate the microbial risk of pathogen ingestion. Their risk value increased significantly high level after irrigation and precipitation.It implies that agricultural activities such as plowing, and fertilizing, and precipitation need be practiced a few days after irrigation considering health risks. The results about field application of the microbial risk assessment using E. coli showed difference according to monitoring time and treatment plot. Result of the microbial risk assessment showed that risk values of ground-water and reclaimed secondary waste water irrigation were lower than directly use of wastewater treatment plants' effluent. This paper should be viewed as a first step in the application of quantitative microbial risk assessment of E. coli to wastewater reuse in a paddy rice farming.

염화비닐(Vinyl Chloride)의 인체 및 수생태계 영향 연구 (Effects of Vinyl Chloride to Human Health and Aquatic Ecosystems)

  • 남선화;안윤주
    • 생태와환경
    • /
    • 제42권3호
    • /
    • pp.271-279
    • /
    • 2009
  • VC는 국제적인 발암등급 체계인 IRIS, IARC, ESIS에 의해 인체발암물질로 평가되고 있으며, 경구, 호흡, 경피 노출 경로를 통해 간세포 다형성 등을 유발하는 것으로 보고된 바 있다. 또한 VC는 자연계에서 쉽게 분해되지 않는 유기 염소계용제로서, 대기, 지표수, 지하수, 먹는물, 토양으로 유출되어 인체를 포함한 환경을 오염시킬 가능성이 높은 것으로 나타났다. 현재 우리나라의 수질환경기준과 먹는물 기준에서는 VC에 대한 규제 항목 및 기준치가 제시되어 있지 않으나, 인체 및 수생태계 위해 우려가 있어 특정수질유해물질 및 수질오염물질로 지정된 바 있다. US EPA, 일본, WHO 등 선진국에서는 법적 항목 및 기준치로 VC를 제도적으로 관리하고 있다. 특히 우리나라에서는 2004년 한강 및 낙동강 유역에서 $0.8\sim4.7{\mu}g\;L^{-1}$ (검출한계 $0.1{\mu}g\;L^{-1}$),개별배출업소 유출수에서 $10.6\sim668{\mu}g\;L^{-1}$의 농도로 VC가 검출된 사례가 있으며, 독일, 일본, 미국 등의 국외에서 검출된 $0.03\sim566{\mu}g\;L^{-1}$ 농도보다 국내 수계 내 VC의 분포 수준이 높은 것으로 나타났다. 국내 인체 위해성 평가 결과 VC에 대한 위해 우려가 높은 것으로 평가된 바 있으며, 생태 위해성 평가는 자료 부족으로 보류된 바 있다. 이 때 활용된 모니터링 자료는 일부 지점 및 단회 기반의 신뢰성 다소 낮은 자료에 국한되므로 지속적인 모니터링 사업을 통해 신뢰성 높은 자료로 대체될 필요가 있다. 또한 물 환경 내 생태독성연구는 일부 시험증에 국한되어 있고, 실험 설계도 VC의 수체 내 농도 감소를 고려하지 않아 결과치가 과다 산정되었을 가능성이 높다. 따라서 지속적으로 다양한 수서생물을 활용한 VC의 생태 독성 자료가 생성되어야 추후 VC에 대한 신뢰도가 높은 생태 위해성 평가가 수행될 것으로 사료된다.

창원시 대산면 강변충적층의 지하수위, 하천수위, 강수량의 관련성 연구

  • 정재열;함세영;김형수;차용훈;장성
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.447-450
    • /
    • 2004
  • This study was conducted to characterize groundwater and river-water fluctuations at a riverbank filtration site in Daesan-myeon adjacent to the Nakdong River, using time series analysis. Water levels from six observation wells from January 2003 to October 2003 were measured. The autocorrelation analysis indicates that the wells are divided into three groups: group 1 represents strong linearity and memory, group 2 intermediate linearity and memory, and group 3 weak linearity and memory. The analysis indicates that groundwater levels in different monitoring wells vary in response to river-water levels, groundwater withdrawal and seasonal rainfall. Cross-correlation was also divided into three groups. Group 1 shows the highest cross-correlation function (0.49 - 0.54) for a lag time of 0 hours, group 2 intermediate cross-correlation function (0.34 - 0.45), and group 3 the lowest cross-correlation function (0.23 - 0.25). Different cross-correlation functions among the 3 groups are interpreted as an effect of tile distance from the river to the pumping wells.

  • PDF

도시홍수방재를 위한 수문모니터링시스템의 적용 (Application of Hydrological Monitoring System for Urban Flood Disaster Prevention)

  • 서규우;나현우;김남길
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1209-1213
    • /
    • 2005
  • It reflects well feature of slope that is characteristic of city river basin of Pusan local. Process various hydrological datas and basin details datas which is collected through basin basis data. weather satellite equipment(EMS-DEU) and automatic water level equipment(AWS-DEU) and use as basin input data of ILLUDAS model, SWMM model and HEC-HMS model In order to examine outflow feature of experiment basin and then use in reservoir design of experiment basin through calibration and verification about HEC-HMS model. Inserted design rainfall for 30 years that is design criteria of creek into HEC-HMS model and then calculated design floods according to change aspect of the impermeable rate. Capacity of reservoir was determined on the outflow mass curve. Designed imagination reservoir(volume $54,000m^3$) at last outlet upper stream of experiment basin, after designing reservoir. It could be confirmed that the peak flow was reduced resulting from examining outflow aspect. Designing reservoir must decrease outflow of urban areas.

  • PDF

보령담수호 유역의 유출 오염부하량 추정 (Estimation of Runoff Pollutant Loadings in Boryung Reservoir Watershed)

  • 최진규;손재권;구자웅;조재영;김영주
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.30-33
    • /
    • 2001
  • This study was carried out to estimate the runoff pollutant loadings for water quality management in Boryung freshwater reservoir watershed. The hydrological monitoring system were operated for water level measurement during $1999{\sim}2000$ and temporal variation of water quality constituents such as pH, EC, total nitrogen, total phosphorus were analysed, periodically. Monthly runoff volumes by TANK model and potential pollutant loadings calculated by unit method were compared with measured values.

  • PDF

도시지역 토지이용에 따른 강우사상별 비점오염물질 유출특성 파악 (A Study on the Characterization of Land use in Urban Areas, according to Nonpoint Pollutant Source Runoff)

  • 류제하;윤춘경;최재호;이한필;황문영;양희정
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.309-316
    • /
    • 2013
  • The Non-Point Sources shows different characteristics over a wide area depending on basin situation and rainfall events etc. In addition, Among various land uses in the urban areas, runoff appears high in the paved area, though small in its size, during a heavy rain than in other land use owing to its high impervious rate, and pollutants become severly accumulated owing to continual transportation of vehicles, characteristically showing high concentrations of runoff in the early stage. As a result, several advanced countries including USA give a special emphasis on the paved area as a target for supervision. In view of these aspects, the research is not only required to consider separated sub-basins which are distributed according to land uses, but also needed to develop a suitable monitoring which is reflected rainfall-runoff relation. The on-site monitoring has been performed to collect data in object watershed as well.

Health-monitoring and system-identification of an ancient aqueduct

  • Chrysostomou, Christis Z.;Stassis, Andreas
    • Smart Structures and Systems
    • /
    • 제4권2호
    • /
    • pp.183-194
    • /
    • 2008
  • An important historical monument of Cyprus is an aqueduct that was built in 1747 to provide water to the city of Larnaca and to its port. Because of its importance to the cultural heritage of Cyprus, the aqueduct has been selected as one of the case-study monuments in the project Wide-Range Non-Intrusive devices toward Conservation of Historical Monuments in the Mediterranean Area (WIND-CHIME). Detailed drawings of the aqueduct obtained from the Department of Antiquities of Cyprus have been used for the development of a computational model. The model was fine-tuned through the measurement of the dynamic characteristics of the aqueduct using forced and ambient vibrations. It should be noted that measurement of the dynamic characteristics of the structure were performed twice in a period of three years (June of 2004 and May of 2007). Significant differences were noted and they are attributed to soil structure interaction effects due to seasonal variations of the water-level in a nearby salt-lake. The system identification results for both cases are presented here. This monument was used to test the effectiveness of shape memory alloy (SMA) pre-stressed devices, which were developed during the course of the project, in protecting it without spoiling its monumental value.

머신러닝 CatBoost 다중 분류 알고리즘을 이용한 조류 발생 예측 모형 성능 평가 연구 (Evaluation of Multi-classification Model Performance for Algal Bloom Prediction Using CatBoost)

  • 김준오;박정수
    • 한국물환경학회지
    • /
    • 제39권1호
    • /
    • pp.1-8
    • /
    • 2023
  • Monitoring and prediction of water quality are essential for effective river pollution prevention and water quality management. In this study, a multi-classification model was developed to predict chlorophyll-a (Chl-a) level in rivers. A model was developed using CatBoost, a novel ensemble machine learning algorithm. The model was developed using hourly field monitoring data collected from January 1 to December 31, 2015. For model development, chl-a was classified into class 1 (Chl-a≤10 ㎍/L), class 2 (10<Chl-a≤50 ㎍/L), and class 3 (Chl-a>50 ㎍/L), where the number of data used for the model training were 27,192, 11,031, and 511, respectively. The macro averages of precision, recall, and F1-score for the three classes were 0.58, 0.58, and 0.58, respectively, while the weighted averages were 0.89, 0.90, and 0.89, for precision, recall, and F1-score, respectively. The model showed relatively poor performance for class 3 where the number of observations was much smaller compared to the other two classes. The imbalance of data distribution among the three classes was resolved by using the synthetic minority over-sampling technique (SMOTE) algorithm, where the number of data used for model training was evenly distributed as 26,868 for each class. The model performance was improved with the macro averages of precision, rcall, and F1-score of the three classes as 0.58, 0.70, and 0.59, respectively, while the weighted averages were 0.88, 0.84, and 0.86 after SMOTE application.