에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로 (Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

무수치 표백술에서 근관내 Base가 표백약제의 누출 방지에 미치는 영향 (THE EFFECT OF INTRACANAL BASE ON PREVENTION OF APICAL LEAKAGE OF BLEACHING AGENTS)

  • 최승호;노병덕;박성호;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.453-464
    • /
    • 1999
  • The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal$^{(R)}$(Kerr Co., USA) was used in 39 teeth and in others, AH-26$^{(R)}$(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal$^{(R)}$ were divided into two groups, and Dentin cement$^{(R)}$(GC corp., Japan) and JRM$^{(R)}$(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26$^{(R)}$ as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement$^{(R)}$ and IRM$^{(R)}$ group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.

  • PDF

Application of optimized time domain reflectometry probe for estimating contaminants in saline soil

  • Dongsoo Lee;Jong-Sub Lee;Yong-Hoon Byun;Sang Yeob Kim
    • Geomechanics and Engineering
    • /
    • 제33권3호
    • /
    • pp.291-299
    • /
    • 2023
  • Monitoring contaminants in waste landfills on a seabed is important because the leachate affects the marine ecosystem and facility stability. The objective of this study is to optimize a time-domain reflectometry (TDR) probe using different coating materials and several electrodes to estimate contaminants in saline soil. Copper concentrations ranging from 0 mg/L to 10 mg/L were mixed in 3% salinity water to simulate contaminants in the ocean environment. Epoxy, top-coat, and varnish were used as coating materials, and two to seven electrodes were prepared to vary the number and arrangement of the electrodes. Test results showed that the varnish stably captured the increase in copper concentration, while the other coating materials became insensitive or caused leakage current. In addition, a TDR probe with more electrodes exhibited stable and distinct electromagnetic signals. Thus, the TDR probe with seven electrodes coated with varnish was effectively used to estimate contaminants in saline soil.

섬유강화형 복합레진전장관의 변연적합도 및 변연누출에 관한 연구 (MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEFENDING UPON LUTING CEMENTS)

  • 김선종;신상완;한중석;서규원
    • 대한치과보철학회지
    • /
    • 제38권5호
    • /
    • pp.618-630
    • /
    • 2000
  • As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiber-reinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements. ($Bistite\;II^(R),\;Super-bond^(R),\;Variolink\;II^(R)$), Zinc phosphate and Glass-Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of $5^{\circ}C\;and\;55^{\circ}C$ in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II($46.78{\mu}m$), Variolink II($56.25{\mu}m$), Super-Bond($56.78{\mu}m$), Glass-Ionomer($99.21{\mu}m$), Zinc Phosphate($109.49{\mu}m$) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

  • PDF

감전사고 방지를 위한 물놀이.입욕시설의 조명설비 시설기준 개선방안 연구 (Improvement of Lighting Installation Technical Standard in Waterpark, Public Bath and Similar Places for the Prevention of Electric Shock)

  • 김종민;김한상;김기현;이건호
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.78-85
    • /
    • 2006
  • 물놀이 입욕시설 내에서 입욕자는 물의 영향으로 인하여 인체의 피부저항이 다른 어느 장소보다도 현저히 낮은 상태에 있게 된다. 따라서 조명기구 등에 누전이 발생할 경우 미약한 전압에서도 치명적인 감전재해의 우려가 있다. 본 연구는 물놀이 입욕시설 내에서의 조명기구에 의한 감전사고를 방지하기 위하여 국내 외 관련규정을 비교 분석하였으며 또한, 국내 시설실태를 파악하였다. 그 결과 국내의 규정은 외국기준에 비해 적용범위가 불명확하고 환경조건의 구별이 불투명하고 사용전압이 높은 것으로 나타났다. 따라서 국내의 규정도 조명시설의 설치높이를 상향조정하고 조명기기의 외함에는 방수등급의 표기, 선간전압으로의 사용전압을 제한하는 등의 개정이 필요한 것으로 나타났다.

오염지하수 유입방지를 위한 압축패커 그라우팅 장치 개발 (Development of the Compressed Packer Grouting Device for Preventing the Inflow of Polluted Groundwater)

  • 조희남;최상일
    • 지질공학
    • /
    • 제19권4호
    • /
    • pp.433-439
    • /
    • 2009
  • 압축패커장치는 지하수관정의 지표하부오염방지시설의 개선을 위하여 개발한 장치이다. 이 장치는 안전잠금장치의 해제와 케이싱의 압축조작이 단순하여 시공이 간편하고, $4.5\;kg/cm^2$의 내압성을 갖고 있어 지하수 누출이 없도록 수밀성을 갖추고 있으며, 단일케이싱을 설치하며 그라우팅을 위한 확공은 300 mm로 굴착 가능하므로 시공비를 절약할 수 있다. 압축패커의 재질은 실리콘 고무를 사용하여 신장율이 590%이고 Pb, Cd, 페놀 등의 유해성분이 기준치 이하거나 불검출되어 우수한 환경성을 가지고 있다. 또한 시공비가 기존의 그라우팅 공법의 35~62% 이하, 환경신기술 제 47호인 팽창 패커 공법의 87% 이하로 시공이 가능한 경제적인 방법이며, 지하수 수질보전등에 관한 규칙, 제주도 지하수개발 이용시설 설치 및 관리기준, 환경부와 농림수산식품부의 소규모수도시설 운영관리 방안 지침 등 관련 법령규정에 적합한 제품이다.

개폐식 대공간 막 구조물에서 지붕 맞댐부 우수차단 시스템의 수밀성 평가에 관한 연구 (A Study on the Evaluation of Watertightness Properties for Rain-Block System in the Sliding-Roof Joint of Large-Span Membrane Structures)

  • 오상근;백기열;이선규
    • 한국건축시공학회지
    • /
    • 제10권3호
    • /
    • pp.129-136
    • /
    • 2010
  • 지붕 개폐형태의 대공간 막 구조물은 멀티미디어적인 요소 및 전천후 공간을 활용할 수 있지만, 다수의 연결 조인트에 의해 구조물이 형성되므로 누수에 취약한 문제점이 있다. 특히 개폐식 지붕 맞댐부위의 우수차단 시스템은 우수의 직접적인 유입을 차단하는 역할을 하고 있으므로 바람을 동반한 강우환경에서도 수밀성능이 요구된다. 따라서 상기의 환경 조건을 부여한 수밀성 실험을 통하여 우수차단 시스템의 디테일에 대한 수밀성능을 평가하고자 한다. 실험 결과, 모든 실험체에서 누수가 발생하였으며, 우수의 유입경로는 동일한 것으로 확인되었다. 특히, 바람에 의하여 물입자들이 구조물 내부로 들이치는 현상이 주원인이므로 이를 보완한 새로운 우수차단 시스템의 디테일이 요구된다. 이 연구를 통해 강우 환경과 바람 환경을 동시에 부여하였을 때 발생될 수 있는 우수 침입 경로를 확인하였으며, 수밀 성능 확보 유무가 사전에 검토되어 져야함을 알 수 있었다. 또한, 디테일을 사전에 작성하여 모형 수밀성 시험을 반드시 시행한 후 그 결과에 따라 설계 디테일의 변경, 개선, 보완시공을 하여야 할 것이다.

GIS를 활용한 고속도로 염화수소 가스 누출 시나리오 기반 리스크 평가 (Risk Assessment Based on Highway Hydrogen Chloride Gas Leakage Scenario Using GIS)

  • 김구윤;이재준;윤홍식
    • 대한원격탐사학회지
    • /
    • 제37권3호
    • /
    • pp.591-601
    • /
    • 2021
  • 국내의 화학 산업이 지속적으로 발전이 이루어짐에 따라 화학물질의 취급량과 운송량은 매년 증가하고 있다. 우리나라 도로 화물운송은 90%이상을 차지하고 있으며, 화학물질 운송도 대부분 도로를 통해 이루어지고 있다. 이러한 화학물질 운송차량들은 사고가 발생하게 되면 대형사고로 이어질 수 있다. 운송차량은 1차 피해인 교통사고뿐만 아니라 2차 피해인 환경 피해 요인들인 수질오염, 토양오염 등을 발생시킬 가능성이 높다. 본 연구는 반포IC와 서초IC 구간을 연구지역으로 설정하여 염화수소 가스 누출에 대한 시나리오를 작성하여, ALOHA 프로그램을 사용하여 예측거리를 측정하고 거리에 따라 염화수소 가스가 도달한 시간을 분석하였다. 또한 GIS를 이용해 시간별로 발생한 피해 영역에 대해서 인구밀도를 이용한 리스크 평가를 수행하였다. 이를 통해 피해 영역에 대해서 예방·대응 방안의 필요성을 제시하였다.

콘크리트 표면 차수벽형 석괴댐의 Zone-1재료에 대한 다짐특성 (Compaction Characteristics of Zone-1 Material in Concrete Faced Rockfill Dam)

  • 여규권;한상현;이재호
    • 한국지반신소재학회논문집
    • /
    • 제6권2호
    • /
    • pp.9-15
    • /
    • 2007
  • 콘크리트 표면 차수벽형 석괴댐(CRFD)에서의 표층부기초지반은 콘크리트 차수벽을 균등하게 지지할 수 있는 지지력과 사면안정을 위한 소요강도를 확보하여야 하며, 콘크리트 차수벽의 누수시 세립토의 유실을 억제할 수 있는 차수성을 유지하여야 한다. 본 연구에서는 사면부 표층기초지반에 대하여 시험시공을 실시하여 다짐회수에 대한 제체의 변위량과 현장다짐밀도의 변화, 살수량에 따른 함수비 변화 등을 측정하여 효율적인 다짐관리기준을 마련하고자 하였다. 일련의 현장다짐시험결과 CFRD에서의 표층부기초지반은 층별 포설두께 및 다짐회수에 따라 영향 받고 있음을 확인할 수 있었다.

  • PDF

지반조사 분석을 통한 지반함몰 위험영향인자 연구 (A Study on Risk Influence Factors of Ground Subsidence through Soil Investigation Analysis)

  • 정호영;이길환
    • 한국방재안전학회논문집
    • /
    • 제10권1호
    • /
    • pp.43-46
    • /
    • 2017
  • 최근 도심지 포화로 전 세계적으로 지하공간개발이 활발히 진행되고 있으며 굴착공사는 지상 및 지하의 굴착 인접 구조물에 의한 다양한 굴착공법으로 시공이 주로 이루어지고 있다. 굴착공사 중 시공 부주의나 시공기술 미흡, 지하수 유출, 급격한 지층의 변화에 대응실패, 토류 시스템 구성품의 문제등으로 인해 각종 지반함몰 사고가 발생하고 있다. 지반함몰 방지를 위해 지반조사 분석을 통한 지반함몰 위험영향인자를 도출하고자 한다. 최근 75개소 지반조사값을 토대로 지반함몰 요인을 분석하고 조사항목으로는 지역별, 통일분류법(U.S.C.S), 공법, 굴착심도를 통해 분석을 하였다.