• Title/Summary/Keyword: Water Efficiency

Search Result 6,704, Processing Time 0.036 seconds

Concept and Indicators of Eco-Efficient Water Infrastructure for Asia and the Pacific

  • Lee, Seung-Ho;Kang, Boo-Sik;Hong, Il-Pyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.2169-2175
    • /
    • 2009
  • This research aims to evaluate the concept of eco-efficient water infrastructure and provides a list of case studies in order to help understand the applicability of eco-efficient water infrastructure to Asia and the Pacific. A set of indicators have been explored to assess eco-efficiency in water infrastructure for the region on a micro and macro scale. The core idea of eco-efficiency, 'more value with less impact (on the environment)', has proven to be applicable in management of water infrastructure. The fundamental elements in eco-efficient water infrastructure should encompass physical infrastructure and non-physical infrastructure, which is more needed particularly in Asian countries. The case studies have demonstrated the applicability of the concept of eco-efficient water infrastructure. The Republic of Korea has provided the case of the eco-friendly approaches to enhance dam management and its innovative solutions how to use water more efficiently through state-of-art technologies. The experiences of Singapore are some of the best evidence to establish eco-efficient water infrastructure, for instance, the NEWater project via application of cutting edge technologies (recycled water) and institutional reform in water tariff systems to conserve water as well as enhance water quality. A list of indicators to assess eco-efficiency in water infrastructure have been discussed, and the research presents a myriad of project cases which are good to represent eco-efficiency in water infrastructure, including multipurpose small dams, customized flood defense systems, eco-efficient ground water use, and eco-efficient desalination plants. The study has presented numerous indicators in five different categories: 1) the status of water availability and infrastructure; 2) production and consumption patterns of freshwater; 3) agricultural products and sources of environmental loads; 4) damages from water-caused natural disaster; and 5) urban water supply and sanitation. There are challenges as well as benefits in such indicators, since the indicators should be applied very carefully in accordance with specific socio-economic, political and policy contexts in different countries in Asia and the Pacific Region. The key to success of establishment of eco-efficient water infrastructure in Asia primarily depends on the extent to which each country is committed to balancing its development of physical as well as non-physical water infrastructure. Particularly, it is imperative for Asian countries to transform its policy focus from physical infrastructure to non-physical infrastructure. Such shift will help lead to implementation of sustainable in Asian countries.

  • PDF

Water Use Efficiency of Subsurface Drip Irrigation and Furrow Irrigation (지하점적관개와 고랑관개의 물 이용 효율)

  • Song, In-Hong;Waller Peter. M.;Choi, C. Yeon-Sik;Kwun, Soon-Kuk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.2
    • /
    • pp.3-13
    • /
    • 2007
  • The primary objective of this study was to compare water use efficiencies between subsurface drip irrigation and furrow irrigation. The uniformity of used drip lines was tested to determine if clogging would be a threat to the long-term success of a subsurface drip irrigation system. Three crops, cantaloupe, lettuce, and bell pepper, were grown in four plots for each irrigation system. Significantly less water was applied with subsurface drip irrigation than with furrow irrigation (29.5 % less for cantaloupe and 43.2 % less for bell poppet) in order to produce similar crop yields. Water use efficiencies with subsurface drip irrigation were significantly higher than those with furrow irrigation fur cantaloupe (P-value = 0.018) and bell pepper (P-value ${\leq}$ 0.001). Drip-irrigated lettuce, a shallow-rooted crop, had moderately higher water use efficiency during the first two seasons, while no difference was observed in the third season. After the experiment, the uniformity of the drip lines was 92.1 % on average and classified as good. The high values fur water use efficiency and uniformity indicate that subsurface drip irrigation can be a sustainable method for conserving irrigation water.

Analysis on the sediment sluicing efficiency by variation of operation water surface elevation at flood season (홍수기 운영수위 변화에 따른 배사 효율 분석)

  • Jeong, Anchul;Kim, Seongwon;Kim, Minseok;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.12
    • /
    • pp.971-980
    • /
    • 2016
  • In general, efficient operation of sediment sluicing is important in economical aspect. In this study, the efficiency of sediment sluicing by various operation at water surface elevation on multi-functional weirs were analyzed using Nays2DH, and we focused on the Dalsung weir at Nakdong river. The results of this study shows that, the same number of flushing channels and water gates were developed due to sediment sluicing, and sediment deposition occurred in upstream region of flushing channels. Also, the sediment sluicing efficiency increased by approximately 4.6% and sedimentation decreased by approximately 4.5% at EL. 14.5 m for operations on water surface elevation exceeding EL. 14.0 m. The mitigation of reservoir sedimentation and extension of maintenance dredging period are possible if the variation of sediment sluicing efficiency in various operation at water surface elevation during flood season are considered.

Preparation and Water Quality Purification of Permeable Concrete Pavement Filled with Microbial-Soil Sheet (미생물토양시트를 충진한 도로포장용 다공성 콘크리트의 제조 및 수질정화특성)

  • Kang, Young-Heoun;Hwang, Pil-Gi;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.727-733
    • /
    • 2009
  • This study was performed to investigate the physical characteristics like compressive strength, permeability, porosity and the water quality removal characteristics of permeable concrete pavement filled with microbial-soil sheet to remove SS, organic matter and nutrients in artificial rainfall. As a result, it can show the removal efficiency is SS 90~95%, COD 85~93%, BOD 80~83%, T-N 61~75%, T-P 71~78% on WAPS I(W1) and WAPS II(W2). Therefore, permeable concrete pavement filled with microbial-soil sheet shows higher removal efficiency(SS 10%, organic matter and nutrients 30%) than a conventional porous concrete(W3). By filling microbial-soil sheet to permeable concrete pavement, we confirm that the function and efficiency are improved significantly and that a naturally-friendly facility can be developed and applied to treat non-point sources.

Membrane contactor and Carbon Dioxide Separation

  • 이규호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.59-101
    • /
    • 2002
  • PVDF is good material for a hollow fiber membrane with high porosity and excellent hydrophobicity. Asymmetric PVDF hollow fiber membranes were prepared by the Loeb-Sourirajan phase inversion method. Asymmetric PVDF hollow fiber membranes could be controlled in pore size and porosity using various additives(LiCl, ZnCl$_2$) and internal coagulants (water, EtOH/water, and DMAc/water mixture). $CO_2$removal efficiency of asymmetric PVDF hollow fiber membranes was 1.2 times high than that of commercialized PP hollow fiber membranes at MEA 5wt% solution. $CO_2$flux of asymmetric PVDF hollow fiber membranes was 2.5 times higher than that of commercialized PP hollow fiber membranes. $CO_2$removal efficiency and absorption rate of asymmetric PVDF hollow fiber membranes were 30 times higher than those of packed column at absorbent $H_2O$. $CO_2$flux of asymmetric PVDF hollow fiber membranes at MEA 5wt% solution was 48 times higher than that of pure water. In the case of MEA 5wt% solution used as an absorbent, the $CO_2$absorption rate and removal efficiency of PVDF hollow fiber membrane were 2.3 times higher than that of a packed column.

  • PDF

The Optimum Control Study for Improving Efficiency of the small hydropower generation in water pipe (수도관로 소수력발전 운영효율 향상을 위한 최적제어 방안)

  • Hong, Jeong-Jo;Rim, Dong-Heui;Kim, Soo-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.126-129
    • /
    • 2008
  • Using a surplus head in presented water supply pipes, we have studied to improve the operating efficiency of small hydro generator, which was chosen for a test model with Sung-Nam and Bo-Ryong small hydro power plant. With regard to power control and countermeasure of water hammer impact, Finally we have represented the optimal control method through the synthetical analysis of existing system symptoms, operation efficiency, the effect of water hammer impact and system configuration.

  • PDF

An Experimental Study to Improve the Characteristics of Electrode Type Humidifier (전극형 가습기의 특성을 개선하기 위한 실험적인 연구)

  • Park, Kyu-Hong;Song, Ha-Jin;Byun, Jae-Young
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.310-315
    • /
    • 2009
  • This investigation was performed to study the characteristics of electricity and heat transfer that occur in the cylinder of electrode type humidifier during the process of water evaporation. Measurements were made to obtain the amount of water evaporation, the consumption of electric power, electrical conductivity, etc according to the materials and shapes of electrode. When the humidifier was in non-drain controlled mode, the number and amplitude of current cycle per minute increased gradually with the lapse of time, whereas for drain controlled mode, it decreased about 40[%] after draining water. It was found that for non-drain controlled mode, the thermal efficiency of humidifier which used SS400, STS316 and wire net electrode type was about 95~96[%] and it was 2~4[%] higher than that of drain controlled mode. Also, it was shown that the thermal efficiency of humidifier which used neighboring six-phase electrode balanced electrically was 4[%] higher than that of existing six-phase type.

A Study on Heat Flow Characteristics during Hot Water Extraction Process (온수추출과정의 열유동 특성에 관한 연구)

  • 장영근;박정원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.549-556
    • /
    • 2001
  • Heat flow characteristics during hot water extraction process was studied experimentally. Data were taken at various outlet port type for the fixed inlet port type, inlet-outlet temperature differences and mass flow rates. In this study, the temperature distribution in a storage tank and an outlet temperature were measured to predict a flow pattern in the storage tank, and a hot water extraction efficiency was analysed with respect to the variables dominating a extraction process. Experimental results show that the extraction efficiency is high in a low flow rate in case of using modified distributor I(MDI) as a outlet port type.

  • PDF

Preparation of Composite Adsorbents by Activation of Water Plant Sludge and Phenolic Resin Mixtures

  • Myung, Heung-Sik;Kim, Dong-Pyo
    • Carbon letters
    • /
    • v.1 no.3_4
    • /
    • pp.154-157
    • /
    • 2001
  • Composite adsorbents were prepared by mixing water plant sludge with phenolic resin having the ratio of 1 : 1, 1 : 2, and 1 : 3 respectively, curing from $100^{\circ}C$ to $170^{\circ}C$ under $N_2$ atmosphere, and then activating with $N_2$ at $700^{\circ}C$. Thermal property, specific surface area and morphology of the composite adsorbents as well as their precursors were measured by TGA, BET and SEM respectively. Removal efficiency of the composite adsorbents to ${NH_4}^+$ and TOC was compared with those of commercial zeolite and activated carbon. The adsorbents presented very promising TOC removal efficiency of 98%, which was identical level to that of commercial activated carbon while they displayed removal efficiency, only 32%, of ${NH_4}^+$. Therefore, this composite adsorbent considered as the alternative material of commercial activated carbon, used as an expensive removal agent of organic substances and THM in water treatment plant and it also suggested a possibility of practical application in other processes.

  • PDF

An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber (충진층식 세정집진기의 집진특성 실험)

  • 유경훈;노희환;최은수;김종균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.