• 제목/요약/키워드: Water Efficiency

검색결과 6,682건 처리시간 0.037초

농업용 보의 수차 발전기 효율 분석 (Efficiency Analysis for Water Turbine Generator of Agricultural Reservoir)

  • 김종겸
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1223-1227
    • /
    • 2013
  • If the factory test efficiency and field operation efficiency of water turbine are different from each other, issues for efficiency warranty can be raised. So, This paper shows the result for comparative analysis of field operating efficiency vs plant testing efficiency of the water turbine generator installed in agricultural reservoir. The efficiency of the induction generator is analyzed by the change of rotational speed with the parameter obtained by test, the efficiency of water turbine is calculated by the change of head with the design flow. Efficiency deviation of induction generator is lower but the variation of developed power is pretty high near the rated speed and the efficiency variation of water turbine is high by the fluctuation of head for constant flow. It was found that factory test efficiency and total efficiency of water turbine generator calculated according to the rotational speed are very close.

해수를 이용한 펄프공장 폐액의 화학적 처리에 관한 연구 (The study of chemical treatment of pulp mill bleaching waste liquor using sea water)

  • 정병곤;이헌모;윤종호
    • 환경위생공학
    • /
    • 제12권1호
    • /
    • pp.39-48
    • /
    • 1997
  • The study was conducted to know the possibility that the removal efficiency of organic and suspended solids(SS) could be increased by suppling of sea water and the optimum amount of sea water to be supplied treat bleaching waste water by lime coagulation settlement at pulp mill process. When the lime dosage was increased, the removal efficiency of COD and SS in the waste water was increased based on the removal efficiency of COD and SS. The lime dosage and removal efficiency was increased proportionally with the lime concentration of 4,000 mg/l, but the increase of removal efficiency was presented slightly above the 4,000mg/l. It was evaluated that the removal efficiencies of COD and SS could be increased and the requirement of lime dosage could be decreased by the sea water supplement. The removal efficiency of SS was most increased when the sea water supplement was 10% or more in the waste water. The removal efficiencies of COD was the best at 4% sea water excepting the dilution efficiency by sea water supplement.

  • PDF

Improving water use efficiency in the Upper Central Irrigation Area in Thailand via soil moisture system and local water user training

  • Koontankulvong, Sucharit;Visessri, Supatra
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.8-12
    • /
    • 2022
  • Water loss is one of the typical but challenging problems in water management. To reduced water loss or increase water efficiency, the pilot projects were implemented in the TTD's irrigation area. Modern soil moisture technology and local level water user training were conducted together as a mean to achieve improved water efficiency. In terms of technology, soil moisture sensors and monitoring system were used to estimate crop water requirement to reduce unnecessary irrigation. This was found to save 16.47% of irrigated water and 25.20% of irrigation supply. Further improvement of water efficiency was gained by means of local level water user training in which stakeholders were engaged in the network of communications and co-planning. The lessons learnt from the TTD pilot project was translated into good water management practices at local level.

  • PDF

한강 및 낙동강 유역의 양수장 지구 물관리효율 평가 (Assessment of Water Management Efficiencies for Irrigation Pumping Stations in the Han River and Nakdong River Basins)

  • 김현준;김철겸;김승
    • 한국농공학회지
    • /
    • 제45권1호
    • /
    • pp.23-32
    • /
    • 2003
  • The objective of this study is assessing water management efficiency using water withdrawals from rivers and water requirements for paddies. The water management efficiency was defined by the ratio of water requirements and water withdrawals. Water withdrawals were estimated using the operating times and pumping capacity of the pumping stations from 1992 to 1999 in the Han River and Nakdong River basins. Water requirements were estimated by adding the evapotranspiration of the crops and infiltrations in the irrigated area. Evapotranspiration from the paddies was calculated by the FAO modified Penman method with observed daily weather data. The monthly water management efficiency was analyzed for each pumping stations and the district offices of KARICO (Korea Agricultural and Rural Infrastructure Corporation). The efficiencies of 59 pumping stations in the Han River basin varied from 19% to 135%, and the average was 61%. The efficiencies of 146 pumping stations in the Nakdong River basin ranged from 17% to 190%, and the average was 72%. There were no good correlations between the water management efficiency and pump capacity or irrigated area, it showed that the water management efficiency was affected by the traditional water management practices rather than the scale of irrigation district.

정수처리에서 미량유해물질 제거를 위한 Peroxone 공정의 적용성 및 경제성 평가 (Evaluation of Applicability and Economical Efficiency of Peroxone Process for Removal of Micropollutants in Drinking Water Treatment)

  • 손희종;김상구;염훈식;최진택
    • 한국환경과학회지
    • /
    • 제22권7호
    • /
    • pp.905-913
    • /
    • 2013
  • We compared the applicability and economical efficiency of peroxone process with those of ozone process in the existing water treatment plant on downstream of Nakdong River. After comparing the peroxone process for removing geosmin with the ozone process in lab scale test, peroxone process showed much higher removal efficiency than the ozone process at the same ozone dosage. Proper range of $H_2O_2/O_3$ ratio were 0.5~1.0 and the half-life of geosmin was about 5.5~6.8 min when the $H_2O_2/O_3$ ratio was set to 0.5 during 1~2 mg/L of ozone dosage. Peroxone process could reduce the ozone dosage about 50 to maximum 30% for the same geosmin removal efficiency compared to the ozone process in the pilot scale test. In case of 1,4-dioxane treatment, peroxone process could have 3~4 times higher efficiency than ozone process at the same ozone dosage. The results of estimating the economical efficiency of ozone and peroxone process for treating geosmin and 1,4-dioxane by using pilot scale test, in case of the removal target was set to 85% for these two materials, the cost of peroxane process could be reduced about 1.5 times compared to ozone process, and in the same production cost peroxone process could have 2~3 times higher removal efficiency than ozone process. The removal efficiency by peroxone process showed a large difference depending on the physicochemical characteristics of target materials and raw water, therefore detailed examination should be carried out before appling peroxone process.

공업용수 투입의 기술적 효율성 분석 (The Study on the Technical Efficiency of Industrial Water in Manufacturing)

  • 민동기
    • 한국수자원학회논문집
    • /
    • 제41권6호
    • /
    • pp.597-603
    • /
    • 2008
  • 본 연구는 수자원정책의 효율성 제고를 위한 정책 방안 마련의 토대를 제공하고자 제조업체에서 투입요소로 사용하고 있는 공업용수의 기술적 효율성을 추정하였다. 이를 위하여 자료포락분석(DEA:Data Envelopment Analysis)기법을 이용하였으며 분석 결과에 의하면 공업용수의 기술적 효율성은 전 산업 평균이 0.407로 추정되어 모든 투입요소가 가변적인 경우의 연구 사례에 비하여 낮은 추정치를 보여준다. 이는 공업용수에 대한 비용이 다른 투입요소에 비하여 낮아 기업 경영진이 공업용수의 효율적인 활용 필요성에 상대적으로 둔감한 결과로 볼 수 있다. 그리고 낮은 기술적 효율성 추정치는 모든 투입요소가 효율적이라고 가정하고 분석한 기존 연구들의 가정에 한계가 있음을 보여 준다.

공업용수의 기술적 효율성 분석 (An Analysis of the Technical Efficiency of Industrial Water Input in Manufacturing)

  • 민동기
    • 환경정책연구
    • /
    • 제8권4호
    • /
    • pp.37-49
    • /
    • 2009
  • 90년대 이후 용수관리 정책이 공급중심에서 수요관리로 정책 전환이 되면서 공업용수 수요량이 급격히 감소하였다. 본 연구에서는 공업용수 사용의 기술적 효율성을 분석하여 이러한 공업용수 수요량 감소가 공업용수의 사용이 효율적으로 이루어진 결과인지 검토하고 향후 공업용수의 기술적 효율성 제고를 통하여 공업용수 사용량을 더 줄일 수 있는지 검토하였다. 본 연구결과에 의하면 공업용수의 기술적 효율성은 1998년도 0.5183에서 2003년도에는 0.4853으로 도리어 약간 감소한 것으로 나타났다. 이는 다른 투입요소의 기술적 효율성에 비하여 낮은 수치로 앞으로 기술적 효율성 제고를 통하여 공업용수 사용량을 더 절감할 수 있음을 보여준다.

  • PDF

지방중소도시의 누수관리방법에 대한 효율성 평가 (Efficiency evaluation of water leakage management methods in local small and medium cities)

  • 황진수;최태호;김기범;구자용
    • 상하수도학회지
    • /
    • 제35권2호
    • /
    • pp.121-133
    • /
    • 2021
  • This study set up the estimates of leakage management efficiency evaluation and leakage management goal that could be used in local water distribution networks efficiency business and modernization business. The data were analyzed using data envelopment analysis and multiple regression analysis. To this end, with leakage management input indices concerning leakage reduction activities (e.g., aged pipe replacement, water meter replacement, leakage restoration, and leakage detection) and leakage management calculation indices (e.g., the increase of revenue water ratio and the reduction of leakage ratio), the data on 22 K-water consignment local water supply systems were analyzed for the years from 2004 through 2018. Using the results of efficiency analysis by data envelopment analysis, the other DMUs (Decision Making Unit) benchmarked the DMU with the highest efficiency to maximize the leakage management efficiency for all DMUs. Through this, leakage management goal estimates were drawn with the input indices of four leakage reduction activities and calculation indices of the increase of revenue water ratio and the reduction of leakage ratio by multiple regression analysis for each group based on the revenue water ratio and leakage ratio. The correlation coefficients of the leakage management goal estimate for the criteria for the revenue water ratio amounted to 0.553 and 0.771. The correlation coefficients of the leakage management goal estimate for the criteria for leakage ratio were 0.397 and 0.865. Accordingly, we estimated the quantity and priority of four leakage reduction activities for the target leakage ratio and revenue water ratio.

응집제 첨가에 의한 침전조의 백수침전 효율 평가 (The Evaluation of White Water Sedimentation Efficiency in Settling Tank by the Addition of Flocculents)

  • 김형진;안정송;유성호
    • 펄프종이기술
    • /
    • 제36권4호
    • /
    • pp.67-76
    • /
    • 2004
  • Because paper industry spends lots amount of water, the recycling of water is very important in economical as well as environmental aspects. In order to optimize the process water recycling system, the efficiency of unit operation for water circulation, such as save-all system, CDS and settling tank, plays an important role in. In this study, the sedimentation efficiency of process water was evaluated by SS measurement with the different amounts of flocculent addition. 3 different kinds of process water were collected from fine paper mill, and applied in laboratory sedimentation equipment for the measurement of settling efficiency of SS materials. The addition amounts of alum and PAC were resulted in optimum efficiency of sediments in the condition of 100 ppm of alum and 500 ppm of PAC respectively. In the comparison of sedimentation efficiency between alum and PAC, alum showed more economical and efficient results. The SS of spill water and the particle size of suspended materials treated by alum flocculents were below 50 ppm and about 1 $\mu$m. It would be considered that the spill water can be substituted to superclear water grade.

전기 인버터 구동 수압 피스톤 펌프 시스템의 효율 성능에 관한 실험적 연구 (An Experimental Study on the Efficiency of the Water Hydraulic Piston Pump System driven by an Electric Inverter)

  • 함영복;박준형;김성동
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.1-7
    • /
    • 2006
  • A water hydraulic pump is likely to have serious problems of high leakage, friction and low energy efficiency. A water hydraulic pump has commonly a fixed displacement type and its outlet flow is adjusted by controlling rotation speed of the pump, which can be implemented by using an electric inverter. This study aims to investigate energy efficiency of the water hydraulic pump system which is driven by an electric inverter. The study is based on the experimental results. The pump which is used in the study shows relatively good efficiency and low leakage, low friction as well. The reasons for the good performance of pump is also investigated.

  • PDF