• 제목/요약/키워드: Water Drop

검색결과 906건 처리시간 0.027초

건조 온도 및 경화시간이 도공지 품질에 미치는 영향 (Effect on the Properties of Coated Paper by Drying Temperature and Curing Time)

  • 박동국;최희연;김영하;이용규
    • 펄프종이기술
    • /
    • 제34권4호
    • /
    • pp.16-21
    • /
    • 2002
  • It was observed that drying temperature and curing time in the paper coating process as well as Tg of the latex used as a binder, greatly affected the properties of the coated paper such as roughness, paper and print gloss, K & N ink drop, and ink set-off. The higher drying temperature induced faster water evaporation and change in binding density, which caused an increase in paper roughness, ink gloss and ink set-off, but decrease in paper gloss and K & N ink drop. The increased curing time promoted latex filming and redistribution of the binder in coating layer. This increased pick strength and ink gloss, but decreased ink trapping. Finally, the higher Tg of the latex showed the wider changing range of these properties.

Dual Swirl 인젝터의 분산각에 관한 해석적 연구 (Numerical Investigation for Spray Angles of Dual Swirl Injector)

  • 정해승;김선진
    • 한국군사과학기술학회지
    • /
    • 제6권4호
    • /
    • pp.132-144
    • /
    • 2003
  • Numerical analysis of the spray angles of Dual swirl injector were investigated to obtain basic design data and to predict the combustion performance. Using the commercial thermal hydraulic program, discharge coefficients and spray angles were numerically analyzed with recess length, pressure drop, velocity ratio, mixture ratio and back hole length. Water was used as simulants for oxidizer and fuel, respectively to compare the experimental results. Swirl injectors were designed to inject oxidizer of 70.5g/s and fuel of 29.5g/s at the pressure drop of 1MPa and two recess lengths were considered. In addition, the effect of injector geometry coefficient and velocity ratio on the discharge coefficient was studied.

Ralu-Pack 250YC를 충전한 충전탑에서 암모니아가스 제거에 관한 연구 (A study on Removal of $NH_3$ Gas in a Towar using a Ralu-Pack 250YC as a Packing Material)

  • 김석택
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.389-392
    • /
    • 2000
  • In this study a packed tower was selected for the treatment apparatus of $NH_3$ gas produced in industry. Formerly latticework packing has been used in preventive facility of treatment of $NH_3$ gas. However recently metallic Ralu-Pack 250YC. structured packing is usually being used in petrochemical production plant. This study is for the application the packing to the $NH_3$ gas treatment in wet scrubbing process. In Air/water system hydraulic pressure drop dependent of specific liquid load and gas capacity factor was continuous and parallel from graph. The tower height can be determuined by the number of transfer unit and the height of transfer unit influenced on liquid distribution.

  • PDF

Hexadecyl Pyridinium Bromide의 임계미셀농도에서 온도의 효과 (The Effect of Temperature on the Critical Micelle Concentration of Hexadecyl Pyridinium Bromide)

  • 김영찬
    • 해양환경안전학회지
    • /
    • 제13권4호
    • /
    • pp.51-54
    • /
    • 2007
  • 화장품과 유처리제 등에 응용할 수 있는 계면활성제인 hexadecyl pyridinium bromide를 사용하여 온도 $40{\sim}60^{\circ}C$ 범위에서 임계미셀농도를 적하법으로 측정한 결과를 이용하여 미셀형성에 따른 열역학적 양을 다항식으로 계산하였다.

  • PDF

계면활성제의 임계 미셀농도에 대한 열역학적 접근 (Thermodynamic Approach on The Critical Micelle Concentration of Surfactant)

  • 김세봉;김영찬
    • 한국응용과학기술학회지
    • /
    • 제28권4호
    • /
    • pp.449-454
    • /
    • 2011
  • This surfactant can be used as a cosmetics and chemical dispersants. The variation of critical micelle concentration(CMC) with temperature for N-eicosyl pyridinium bromide over the range $40^{\circ}C$ to $60^{\circ}C$ has been measured by drop methods. Thermodynamic quantities for micellization of N-eicosyl pyridinium bromide in water have been calculated by polynominal equation.

휜-관 열교환기에 있어서 각종 휜 형상의 성능 특성에 관한 실험적 연구 (Experimental study of performance characteristics of various fin types for fin-tube heat exchanger)

  • 윤백;김영생;박환영;박현연
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.484-491
    • /
    • 1999
  • Air side heat transfer and pressure drop for ø9.52 fin-tube heat exchanger with various types of slit and louver fins were measured, and compared with wave-slit fin. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively. Actual heat exchanger was tested using water, and the tests were performed for 2 row heat exchangers with 3 different fin spacings, 1.3, 1.5 and 1.7mm. The overall performance of the enhanced fins was evaluated by comparing heat transfer coefficient with respect to fan power.

  • PDF

장력 감김으로 부착된 가로방향 휜-미니채널의 공기측 열전달 특성 (Air Side Heat Transfer Charactieristics of Tension Wound Transverse Fin with Minichannel)

  • 김종수;임용빈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.701-706
    • /
    • 2005
  • Pipes, tubes. and tubular sections with external transverse high fins have been used extensively for heating cooling, and degumidifying air and other gases. This work was performed to investigate an air side heat transfer charactieristics of minichannel with tension wound transverse fin. This estimate was confirmed conversion heat capacity the air side surface area enlargement and heat transfer charactieristics performed available inlet tube side hot water mass flux or outlet tube side air frontal air velocity. The most suitable tension wound transverse finned minichannel was measured extremely low in air side pressure drop and fin effectiveness $3.3\~4.4$. The pressure drop $0.9\~2.8Pa$ was ranged frontal air velocity $0.5\~1.2m/s$. It is also appeared that heat transfer in air side could be better conversion heat area which has been increased $330\%$ of heat capacity compared with the bare tube.

헬리컬코일형 $CO_2$ 가스쿨러의 열전달과 압력강하 (Heat Transfer and Pressure Drop of $CO_2$ Gas Cooler in a Helically Coiled Tube)

  • 경남수;유태근;손창효;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.246-247
    • /
    • 2005
  • The paper presents the heat transfer characteristics during cooling process of carbon dioxide($CO_2$) in a helically coiled tube. The main components of the apparatus consist of a receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section with the inner diameter 4.55 [mm] is a tube in tube type heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The main results were summarized as follows : The heat transfer coefficient increases with respect to the decrease of the gas cooler pressure in a supercritical region and the increase of the refrigerant mass flux. The pressure drop decreases in increases of the gas cooler pressure and increases with respect to increases the refrigerant mass flux.

  • PDF

배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구 (An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve)

  • 오철;문성배;손용길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

와이어 코일이 삽입된 나선형 내면가공관의 열전달 및 압력강하 특성 (Characteristics of Heat Transfer and Pressure Drop for Spirally Indented Tubes with Wire Coil Inserts)

  • 최인수;박병덕;남상철
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.395-401
    • /
    • 2001
  • The characteristics of heat transfer and pressure drop through tubes has been investigated experimentally for a compound heat transfer enhancement. The test tubes were spirally indented tubes with wire coil inserts which had a various combinations of pitch and helix angles. Pure water was used as working fluids for the experiments, Heat transfer coefficients and friction factors of the test tubes were evaluated from the values of measured temperatures, flow rates and pressure drops. An performance evaluation was performed to find an optimal combination of spirally indented tubes with wire coil inserts. When the helix angle of wire coil insert are $71^{\circ}-72^{\circ}$, the best heat transfer enhancement was shown. The friction factor was 9 - 13 times higher than those in smooth tubes, and the heat transfer was enhanced a maximum of 500%.

  • PDF