• Title/Summary/Keyword: Waste factor

Search Result 545, Processing Time 0.026 seconds

Application of QUAL-2E Model for Water Quality Management in the Keum River -Waste loads Allocation Analysis by Considering Autochthonous BOD- (금강수계의 수질관리를 위한 QUAL-2E 모델의 적용(II) -자생BOD를 고려한 허용오염부하량 산정-)

  • 김종구;이지연
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=$\beta$(sub)5$\times$chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80~20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain II grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07mg/$\ell$, belong to III grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to II grade of water quality standard as below 3mg/$\ell$ of BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50~100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97~79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.

  • PDF

Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation (몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산)

  • Lee, Kyu-Young;Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.503-510
    • /
    • 2020
  • Concrete is one of the most widely used materials as the shielding structures of a nuclear facilities. It is also the most generated radioactive waste in quantity while dismantling facilities. Since the concrete captures neutrons and generates various radionuclides, radiation measurement and analysis of the sample was fulfilled prior to dismantle facilities. An HPGe detector is used in general for the radiation measurement, and effective correction factors such as geometrical correction factor, self-absorption correction, and absolute detector efficiency have to be applied to the measured data to decide exact radioactivity of the sample. Correction factors are obtained by measuring data using a standard source with the same geometry and chemical states as the sample under the same measurement conditions. However, it is very difficult to prepare standard concrete sources because concrete is limited in pretreatment due to various constituent materials and high density. In addition, the concrete sample obtained by core drill is a volumetric source, which requires geometric correction for sample diameter and self absorption correction for sample density. Therefore in recent years, many researchers are working on the calculation of effective correction factors using Monte carlo simulation instead of measuring them using a standard source. In this study we calculated, using Geant4, one of the Monte carlo codes, the correction factors for the various diameter and density of the concrete core sample at the gamma ray energy emitted from the nuclides 152Eu and 60Co, which are the most generated in radioactive concrete.

Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test (Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정)

  • Kim, Chul Woong;Lee, Se Ho;Shin, Dong Rok;Lee, Ji Yong;Park, Jae Han;Ahn, Yoon Hee;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.

A Study on Electrodeionization for Purification of Primary Coolant of a Nuclear Power Plant (원자력 발전소의 일차 냉각수 정화를 위한 전기탈이온법의 기초연구)

  • Yeon, Kyeong-Ho;Moon, Seung-Hyeon;Jeong, Cheorl-Young;Seo, One-Sun;Chong, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.73-86
    • /
    • 1999
  • The ion-exchange method for the purification of primary coolant has been used broadly in PWR(pressurized water reactor)-type nuclear power plants due to its high decontamination efficiency, simple system, and easy operation. However, its non-selective removal of metal and non-radionuclides shortens its life, resulting in the generation of a large amount of waste ion-exchange resin. In this study, the feasibility of electrodeionization (EDI) was investigated for the purification of primary cooling water using synthetic solutions under various experimental conditions as an alternative method for the ion exchange. The results shows that as the feed flow-rate increased, the removal efficiency increased and the power consumption decreased. The removal rate was observed as a 1000 decontamination factor(DF) at a nearly constant level. For the synthetic solution of 3 ppm TDS (Total Dissolved Solid), the power consumption was 40.3 mWh/L at 2.0 L/min of feed flow rate. The higher removal rate of metal species and lower power consumption were obtained with greater resin volume per diluting compartment. However, the flow rate of the EDI process decreased with the elapsed time because of the hydrodynamic resistivity of resin itself and resin fouling by suspended solids. Thus, the ion-exchange resin was replaced by an ion-conducting spacer in order to overcome the drawback. The system equipped with the ion-conducting spacer resolved the problem of the decreasing flow rate but showed a lower efficiency in terms of the power consumption, the removal rate of metal species and current efficiency. In the repeated batch operation, it was found that the removal efficiency of metal species was stably maintained at DF 1000.

  • PDF

Establishment of National Park Management Policy with Elimination of Entrance Fee (국립공원(國立公園) 입장료(入場料) 폐지(廢止)에 따른 국립공원(國立公園) 관리정책(管理政策) 수립(樹立) 방안(方案))

  • Lee, Ju-Hee;Bae, Min-Ki
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.1
    • /
    • pp.96-106
    • /
    • 2007
  • The purpose of this paper was to identify the effects of elimination of entrance fee (EEF) affecting visitor's satisfaction (VS) and management sectors such as natural resources (NRs), park facilities, transportation, visitor service, visitor atmosphere (VA) in national parks (NPs). This research had obtained data through a questionnaire, which surveyed 336 visitors at Gayasan NP in 2006. The data were analyzed the data using descriptive statistical methods, Pearson's correlation analysis, and multiple linear regression method. It was found that 1) About EEF, 72.6% of respondents agreed. 2) As entrance fee was abolished, respondents predicted that degree of VA such as crowding, waste throwing, disorder etc. grew worse most. On the other hands, respondents predicted number and quality of commercial lodging facilities, festival, and local products would improved. 3) Respondents predicted that degree of VS would worse. 4) in multiple regression analysis, the relative contribution of the VA on VS have been determined to have respectively 1.84 times more important than that of the change degree of NRs. The results suggested that the management of VA in NP was the most important factor to prevent decline of VS. This paper would be helpful to establish national park management policy after EEF.

Food Materials for School Foodservices on High-quality Products, Local Products and Fresh-cut Products - Dietitian's Choice in Elementary, Middle and High Schools in Gyeong-gi Province - (학교급식 식재료로서 지역 농산물, 고품질농산물과 신선편이 채소의 이용현황과 필요에 관한 연구 - 경기지역 초.중.고등학교를 중심으로 -)

  • Kang, Heui-Yun;Jung, Eun-Hee;Rhie, Seung-Gyo
    • The Korean Journal of Community Living Science
    • /
    • v.20 no.3
    • /
    • pp.397-411
    • /
    • 2009
  • The use of local product foods and fresh-cut products, the dietitian's recognition, the required items and the quality for school foodservice was investigated to increase the consumption of high-quality agricultural products. Data from 578 elementary schools, 228 middle schools and 116 high schools were collected by school foodservice personnels in each regional Education Administration in Gyeong-gi province. The first criteria of buying food materials was reliability/safety for all school foodservice. The second criteria were the origin of the product and freshness/ripeness for elementary and middle schools and high school, respectively. The most important consideration for selecting a supplier was the quality of the material. The appearance/status of the food was the first factor for buying food materials. The origin and the seasonality were very important for buying farm products. Dietitians in Gyeong-gi province recognized the local products, and used them weekly. The advantages of using local products were the quick supply, freshness and safety. On the other hand, the disadvantages were the lack of information and the uncertainty of supply. Sixty eight percent of the subjects had experienced the high-quality agricultural products in school meals, but the frequency was low. The main reasons for not servicing high-quality agricultural products were the high cost and the lack of trust on the quality. Among fresh-cut products, seasonings and root vegetables were purchased most frequently, but leaf vegetables was 5.7% only. The purchase of fresh-cut products was not frequent, but usually satisfied. The advantages of fresh-cut products were the reduced workload and waste, but the reason for not using them were poor hygiene and the high price. The diverse supply system and the promotion of the local product foods would be necessary since the most food materials were purchased through suppliers. In addition, the problems related to the high cost and distrust should be resolved to expand the consumption of the high-quality agricultural products and the fresh-cut vegetables. The institutions for certifying the quality should be needed to increase the confidence of these products.

  • PDF

A Coupled Hydro-Mechanical Analysis of a Deep Geological Repository to Assess Importance of Mechanical Factors of Bentonite Buffer (심층 처분 시설의 수리 역학적 해석을 통한 벤토나이트 버퍼의 역학적 영향 인자 중요도 평가)

  • Jeon, Yoon-Soo;Lee, Seung-Rae;Kim, Min-Seop;Jeon, Jun-Seo;Kim, Min-Jun
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.439-455
    • /
    • 2019
  • A buffer is the major component of a high level radioactive waste repository. Due to their thermal conductivity and low permeability, bentonites have been considered as a key component of a buffer system in most countries. The deep geological condition generates ground water inflow and results in swelling pressure in the buffer and backfill. Investigation of swelling pressure of bentonite buffer is an important task for the safe disposal system. The swelling pressure that can be critical is affected by mechanical and hydro properties of the system. Therefore, in this study, a sensitivity analysis was conducted to examine the effect of hydro-mechanical (HM) behaviors in the MX-80 bentonite. Based on the results of the swelling pressure generation with HM model parameters, a coupled HM analysis of an unsaturated buffer and backfill in a deep geological repository was also carried out to investigate the major factor of the swelling pressure generation.

Optimal Culture Conditions on the Keratinase Production by Bacillus sp. SH-517. (Bacillus sp. SH-517에 의한 keratinase의 생성 최적 배양 조건)

  • Bang, Byung-Ho;Rhee, Moon-Soo;Lim, Ki-Hwan;Yi, Dong-Heui
    • Journal of Life Science
    • /
    • v.18 no.6
    • /
    • pp.839-844
    • /
    • 2008
  • A strain SH-517 which produce extracellular keratinase, was isolated from the soil of a poultry waste and a poultry factory. An isolate SH-517 was identified as Bacillus sp. based on its morphological and biochemical characteristics. The optimal culture conditions for the production of keratinase by Bacillus sp. SH-517 were investigated. The optimal medium composition for keratinase production was determined to be 2.0% chicken feather as carbon source, 0.5% beef extract as organic nitrogen source, 0.5% $KNO_3$ as inorganic nitrogen source and 0.06% KCl, 0.05% NaCl, 0.04% $KH_2PO_4$, 0.03% $K_2HPO_4$ as mineral source and 0.01% yeast extract as growth factor. The optimal temperature and pH of medium were shown $40^{\circ}C$ and 8.5 with shaking culture (180 rpm/min), respectively. The maximum keratinase production reached maximum of 125 units/ml/min after 42 hr of cultivation under the optimal culturing conditions.

A Study on Design of Vacuum Silo for Batch Treatment System for Dredged Soil (준설토 일괄처리시스템을 위한 진공사이로 설계에 관한 연구)

  • Kim, Yong-Seok;Yang, Hae-Rim;Kim, Hac-Sun;Jeoung, Chan-Se;Yang, Soon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.571-577
    • /
    • 2012
  • In this study, a small movable batch treatment system for dredging soil deposited in a rain water tube is proposed; further, a vacuum silo sorting separation device with a vacuum silo, first-stage sorting separator, and conveyor is designed. The vacuum silo sorting separation device also consists of a storage tank, transferring screw, vacuum gate, screen bar, screen bar cleaner, and vacuum discharging device. In view of the fact that the flow of drawn air in the storage tank is a major factor influencing the sorting separation performance, the optimum shape of the tank is determined by CFD flow analysis. In addition, by using CAE structure analysis, the safety of a storage tank made of boards is examined. The specifications of the vacuum silo sorting separation device are determined by conducting mechanical and dynamic simulations of the driving mechanism of the vacuum silo sorting separation device through 3D-CAD modeling. Following this study, we will design a drum-screen-type second sorter, a decanter-type dehydration device, and waste water tank and pump as a secondary device. Further, on the basis of this design, we will construct a prototype model and carry out a field test.

Analysis by Environmental Factor of Similar Closed Non-sanitary Landfills (사용종료된 유사비위생 매립지들의 환경인자 분석)

  • Lee, Byungchan;Lee, Minhee;Park, Sangchan;Jeong, Seonki;Han, Yangsu;Yeon, Ikjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.27-33
    • /
    • 2009
  • In this study, it was analysed physical characteristics, TS, moisture, C/N ratio, leaching test, and element analysis in landfill wastes of 10 years old without landfill pretreatment. The Organic material content was 7.2%~23.5% and soil was the main inorganic materials which it's rate was 54.1%~71.0%, in landfill wastes. The results of TS, VS, and moisture were represented 51.5%~68.1%, 23.6%~56.1%, 32.0%~48.4%, respectively. The analysis of hazardous materials did not indicate Hg, $Cr^{+6}$, CN, Organic Phosphorus, TCE and PCE, however the Pb of leaching materials showed 0.023~0.092 mg/L, which was the highest. As the result of the element analysis, C was 47.74%~56.72%, N was 4.09%~9.92%, the C/N ratio was 5.76~12.57 and the result of soils around landfill was the highest heavy material, Pb, 2.465 mg/kg~10.251 mg/kg. The objectives of this paper are to investigate states, stabilization of these closed landfills and to gain suitable data for post-closure care using some parameters through analysis of landfill environment.

  • PDF