• Title/Summary/Keyword: Waste Water Treatment System

Search Result 241, Processing Time 0.036 seconds

Solid Waste from Swine Wastewater as a Fuel Source for Heat Production

  • Park, Myung-Ho;Kumar, Sanjay;Ra, ChangSix
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.11
    • /
    • pp.1627-1633
    • /
    • 2012
  • This study was to evaluate the feasibility of recycling the solids separated from swine wastewater treatment process as a fuel source for heat production and to provide a data set on the gas emissions and combustion properties. Also, in this study, the heavy metals in ash content were analyzed for its possible use as a fertilizer. Proximate analysis of the solid recovered from the swine wastewater after flocculation with organic polymer showed high calorific (5,330.50 kcal/kg) and low moisture (15.38%) content, indicating that the solid separated from swine wastewater can be used as an alternative fuel source. CO and NOx emissions were found to increase with increasing temperature. Combustion efficiency of the solids was found to be stable (95 to 98%) with varied temperatures. Thermogravimetry (TG) and differential thermal analysis (DTA) showed five thermal effects (four exothermic and one endothermic), and these effects were distinguished in three stages, water evaporation, heterogeneous combustion of hydrocarbons and decomposition reaction. Based on the calorific value and combustion stability results, solid separated from swine manure can be used as an alternative source of fuel, however further research is still warranted regarding regulation of CO and NOx emissions. Furthermore, the heavy metal content in ash was below the legal limits required for its usage as fertilizer.

Integrated Eco-Engineering Design for Sustainable Management of Fecal Sludge and Domestic Wastewater

  • Koottatep, Thammarat;Polprasert, Chongrak;Laugesen, Carsten H.
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • Constructed wetlands and other aquatic systems have been successfully used for waste and wastewater treatment in either temperate or tropical regions. To treat waste or wastewater in a sustainable manner, the integrated eco-engineering designs are explained in this paper with 2 case studies: (i) a combination of vertical-flow constructed wetland (CW) with plant irrigation systemfor fecal sludge management and (ii) integrated CW units with landscaping at full-scale application for domestic wastewater treatment. The pilot-scale study of fecal sludge management employed 3 vertical-flow CW units, each with a dimension of $5{\times}5{\times}0.65m$ (width ${\times}$ length ${\times}$ media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/$m^2.yr$ and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80 - 96%. The accumulated sludge layers of about 80 - 90 cm was found at the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation Sunflower plant (Helianthus annuus) plots, each with a dimension of $4.5{\times}4.5m$ ($width{\times}length$). In the study, the CW percolate were fed to the treatment plots at the application rate of 7.5 mm/day but the percolate was mixed with tap water at different ratio of 20%, 80% and 100%. Based on a 1-year data of 3-crop plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increasing in CW percolate ratios. The highest plant biomass yield and oil content of 1,000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower is found. In addition to the pilot-scale and field experiments, a case study of the integrated CW systems for wastewater treatment at Phi Phi Island (a Tsunami-hit area), Krabi province, Thailand is illustrated. The $5,200-m^2$ CW systems on Phi Phi Island are not only for treatment of $400m^3/day$ wastewater from hotels, households or other domestic activities, but also incorporating public consultation in the design processes, resulting in introducing the aesthetic landscaping as well as reusing of the treated effluent for irrigating green areas on the Island.

  • PDF

Developing Advanced Total Recycling Method of FRP Boats (FRP선박의 일괄 재처리 방법의 개선)

  • Lee, Seung Hee;Yoon, Koo Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.1
    • /
    • pp.53-59
    • /
    • 2013
  • Since 1990s, the major recycling methods for mechanical recycling of FRP(Fiber Reinforced Plastics)boats has involved shredding and grinding of the scrap FRP in a new recycled product. But still it leads to secondary problem such as air pollution, unacceptable shredding noise level and few limited applications. This study is to propose a newly advanced method which is more efficient and environment friendly waste FRP regenerating system. As extracting FRP layer and making the recycled fiber for recycled-fiber reinforced concrete(RFRC) from waste FRP, the recycling process has some merits in a sense of the recycling energy and the environmental effects. In this study, for those tasks, spectro-chemical differentiation method and coloring water-soluble dye treatment makes the roving layer more distinguishable photophysically. Also that has remarkably reduced safety hazards and energy. Using the mechanical properties of polymers and composite, FRP with the orthotropic and laminated plastic structure has been easily separated in the new extracting system. Also the new method has introduced five kind of separating manuals for the some different compositions of FRP boats. The roving fiber of laminated glass-fiber layer is as good as the polyvinyl fiber which is cost-high commercial fiber to increasing strength of concrete products. The early study has shown the effectiveness of laminated glass-fiber layer which also is chemical-resistant due to the resin coating. These results imply that more efficient and environment friendly recycled glass fiber can be better applied to the fiber reinforced concrete(FRC) substitute and this study also has shown wide concrete applications with RFRC from the waste FRP boat.

A Study on the Pyrolysis System Development for Oil Recovery from Waste Fishing Nets and Ropes (오일 회수를 위한 폐로프와 폐어망 열분해 장치 개발에 대한 연구)

  • Kim Yong-Seop;Yu Jeong Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.2
    • /
    • pp.43-51
    • /
    • 2001
  • Now our ocean environment pollution is very serious. Its harm hinders in marine breeding and the safe navigation of ships at the coast. We have used an assembly system for a measure taken against environment pollution like this. But, here are some problems awaiting solution. First, most of combustible materials among ocean waste are high polymer, so it is necessary some special equipment to incinerate them. In the process we can't overlook air pollution by exhaust gas. Also, when we reclaim these wastes, we remember that they can't be decomposed naturally and leaking water may pollute soil. Thus now a days new treatment method has been developed, it recycles and doesn't product secondary pollution materials by recovering oil from pyrolysis. For it, this study investigated chemicalㆍphysical properties of wastes. And it found condition of recovering the most oil. Also it probed that the variation of temperature raising speed affects the weight reduction characteristics of wastes. Also, while studying recovered oil by waste pyrolysis and the rate of non-condensing gas in accordance with the variation of temperature raising speed. Finally we had confidence the development of pyrolysis oil recovery would succeed because we carried out evaluation at an economic point of view about it.

  • PDF

Characterization of Membrane Fouling and It's Optimal Chemical Cleaning Method in MF Process using D dam water (D댐수를 이용한 정밀여과 공정에서 막오염 특성 및 최적 화학세정방법 조사)

  • Kim, Chung H.;Lim, Jae L.;Lee, Byung G.;Chae, Seon H.;Park, Min G.;Park, Sang H.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.559-569
    • /
    • 2007
  • The purposes of this study were to find the main foulant of membrane and the optimal chemical cleaning method for MF(microfiltration) drinking water treatment system using D dam water as water source. The MF pilot plant which can treat maximum $500m^3/d$ consisted of 3 racks and was operated for 10 months under various operation conditions. After 10 months operation, $1^{st}$ and $2^{nd}$ rack of membrane pilot plant system were cleaned chemically and the degree of the restoration of the fouled membrane in terms of the pure water flux was detemnined. Inorganic compounds which contained in chemical cleaning waste was analyzed by Inductively Coupled Plasma (ICP). One membrane module for 3rd rack was disjointed and membrane fouling materials, especially inorganic compounds were investigated by Electron Probe Microanlysis (EPMA) to elucidate the reason of TMP increase. And also, the various chemical reagents (1N HCl or $H_2SO_4$, oxalic acid as acid and 0.3% NaOCl as alkali) were tested by combination of acid and alkali to determine the optimal chemical cleaning method for the MF system using micro-modules manufactured using the disjointed module. It was verified that the inside and outside of membrane module was colorized with black. As a result of the quantitative and semi-qualitative analysis of membrane foulant by ICP, most of inorganic foulant was manganese which is hard to remove by inorganic acid such as HCI. Especially, it was observed by EPMA that Mn was attached more seriously in inside surface of membrane than in outside surface of that. It was supposed that Mn fouling in inside surface of membrane might be caused by the oxidation of soluble manganese (Mn(II)) to insoluble manganese ($MnO_2$) by chlorine containing in backwashing water. The optimal cleaning method for the removal of manganese fouling was consecutive cleaning with the mixture of 1N HCl and 1% of oxalic acid, 0.3% NaOCl, and 1N HCl showing 91% of the restoration of the fouled membrane.

Bioreactor Systems for the Cometabolic Biodegradation of Trichloroethlene (트리클로로에틸렌의 공동대사적 생분해를 위한 생물반응기 시스템)

  • 이은열
    • KSBB Journal
    • /
    • v.16 no.6
    • /
    • pp.527-532
    • /
    • 2001
  • Trichlooethylene (TCE) has become a widespread contaminant in air, soil, and underground water due to extensive industrial used and improper disposals. Since TCE is a suspected carcinogen and constitutes public health concerns, many treatment systems have been investigated to remove this hazardous waste. One of the most premising reactor systems for the treatment of TCE is trickling biofilter (TBF), in which monooxygenase (MO), the corresponding enzyme for initiating primary substrate oxidation, fortuitously degrades TCE via cometabolism. TCE, however, is not easily treated by simple TBF. This is mainly due to the toxicities of TCE and its degradation products to microbial film in TBF. In this paper, recent progresses on the development of bioreactor system for the treatment of TCE, especially gas-phase TCE, are reviewed. The potentials of novel biofilm reactor systems were also discussed for the long-term continuous treatment of TCE.

  • PDF

Information security auditing Framework in Industrial control system (산업제어시스템 정보보안 감리 프레임워크 연구)

  • Lee, Chul-Soo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.1
    • /
    • pp.139-148
    • /
    • 2008
  • Information technology have led to change the automation of large industrial control system as well as business system and environments. Industrial control system(ICS) is vital components of most nation's critical infrastructures such as electricity, natural gas, water, waste treatment, transportation and communication that are based of national security, safety of citizen and development of national economy According to the change of business environment, organizational management pushed integration all of the system include MIS and ICS. This situation led to use standard information technologies for ICS, this transition has been to expose ICS to the same vulnerabilities and threats that plague business system. Recently government obliged owners of the public information system to audit for safety, efficiency and effectiveness, and also obliged the owners of national infrastructure to improve their system security as a result of vulnerability analysis. But there doesn't prepare a security architecture and information security auditing framework of ICS fur auditing. In this paper, I suggested the security architecture and information security auditing framework for ICS in order to prepare the base of industrial system security auditing.

A Practical New Technology of Removing Algal Bloom: K-water GATe Water Combine (조류(藻類)제어를 위한 실용적 신기술 : K-water 녹조수상콤바인)

  • Shin, Jae-Ki;Kim, Hojoon;Kim, Sea Won;Chong, Sun-A;Moon, Byong Cheun;Lee, Sanghyup;Choi, Jae Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.3
    • /
    • pp.214-218
    • /
    • 2014
  • We introduce a technical equipment of GATe (Green (algae)-tide) water combine developed by K-water. The GATe water combine consists of five modules: main body and buoyant, transfer hopper, screen conveyer, sludge remover, and separator of algae and waste. Also a sprinkler, as the pre-treatment step if necessary, is equipped to the device to spread out environmental-friendly algaecide under the circumstance that the level of algal bloom does not reach to the scum-forming condition. The overall module system of this device is very simple. Based on the field test, the device covers surface area of ca. $500,000m^2day^{-1}$ during the period from May to July, and treats water volume as much as $500,000m^3day^{-1}$ in spite of some variation depending on the water quality condition. The removal efficiency of the device appeared to be over 90%. In addition, the operating duration of the device was able to expand to cover the period between March and November. We expect this new technology can be used to solve algal bloom problems in drinking water resource and public water area.

Analysis of cause of engine failure during power generation using biogas in sewage treatment plant (하수처리장 바이오가스를 이용한 발전시 가스엔진의 고장원인 분석)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.13-29
    • /
    • 2016
  • In this study, we analyzed the causes of major faults in the biogas plant through the case of gas engine failure when cogenerating electricity and heat using biogas as a fuel in the actual sewage treatment plant and suggested countermeasures. Hydrogen sulfide in the biogas entering the biogas engine and water caused by intermittent malfunction of the water removal system caused intercooler corrosion in the biogas engine. In addition, the siloxane in the biogas forms a silicate compound with silicon dioxide, which causes scratches and wear of the piston surface and the inner wall of the cylinder liner. The substances attached to the combustion chamber and the exhaust system were analyzed to be combined with hydrogen sulfide and other impurities. It is believed that hydrogen sulfide was supplied to the desulfurization plant for a long period of time because of the high content of hydrogen sulfide (more than 50ppm) in the biogas and the hydrogen sulfide was introduced into the engine due to the decrease of the removal efficiency due to the breakthrough point of the activated carbon in the desulfurization plant. In addition, the hydrogen sulfide degrades the function of the activated carbon for siloxane removal of the adsorption column, which is considered to be caused by the introduction of unremoved siloxane waste into the engine, resulting in various types of engine failure. Therefore, hydrogen sulfide, siloxane, and water can be regarded as the main causes of the failure of the biogas engine. Among them, hydrogen sulfide reacts with other materials causing failure and can be regarded as a substance having a great influence on the pretreatment process. As a result, optimization of $H_2S$ removal method seems to be an essential measure for stable operation of the biogas engine.

A Study on the Characteristics of Wastewater Treatment by Rapid Infiltration Using Sand Soil (사토(砂土)를 이용(利用)한 급속토양삼투법(急速土壤滲透法)의 폐수처리(廢水處理) 특성(特性)에 관한 연구(研究))

  • Yang, Sang Hyon;Cho, Woong Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.3
    • /
    • pp.23-31
    • /
    • 1987
  • In land treatment systems for organic waste removal, especially rapid intiltration method is well known as less climatic restrictions and less field area requirements as against the others. Therefore the present study on rapid infiltration is aimed to survey the waste removal rate, infiltration rate, variation of dissolved oxygen due to biological oxygen absorption and pH decrement using pilot infiltration column filled with permeable soil(sand) as media, also to find the waste load(COD) per unit area and nitrate conversion ratio from TKN. The results obtained here are as follows. 1) When the depth of sand layer is more than 1 meter, the COD removal would be reached steadly to 90% or more under the infiltration rate below 15~20cm/day, and would be no problem due to leached organic pollutants considering the depth of ground water table. 2) The COD removal per unit area($m^2$) can readily be expected to 10~14g/day with proper operation, and the decomposition of substrate would be attained mostly at the surface layer of the media. 3) Generally the conversion of TKN to the $NO_3{^-}$-N is seemed to be proportional to the COD removal rate if provided proper retention time.

  • PDF