Development of Trickling Bioreactor(TBR) for Trichloroethylene biodegradation by Pseudomonas cepacia G4

  • 이은열;예병대;박성훈
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.410-413
    • /
    • 2000
  • TBR에 공급되는 성장기질인 phenol의 농도에 따른 TCE 분해 효율 변화를 살펴보았다. Phenol 공급이 없는 경우에서의 TCE 제거효율은 평균 42.8%로 유지된 반면, phenol을 0.94 ppm 농도로 공급해줌으로써 TCE 분해 효율을 16% 정도 증가시킬 수 있었다. 따라서 TBR에 알맞은 양의 성장기질을 공급하면, TCE 분해 과정에서 불활성화되는 효소 및 세포의 재활성화를 통해 TCE 분해 효율이 증가시킬 수 있었다.

  • PDF

Growth of Spirulina platensis in Effluents from Wastewater Treatment Plant of Pig Farm

  • Hong, Seok-San
    • Journal of Microbiology and Biotechnology
    • /
    • 제3권1호
    • /
    • pp.19-23
    • /
    • 1993
  • Spirulina platensis NIES 39 was grown in effluents from a wastewater treatment plant utilizing activated sludge process at a pig farm to reduce pollutants and to produce feed resources. The addition of 2 g/l NaCl was required for the growth of S. platensis in the effluents with about 100 mg/l ammonia nitrogen concentration. The growth was stimulated by the addition of 2 g/l sodium bicarbonate and 4 mg/l ferrous sulfate. The microorganism grew well at pH 8~11, and the optimum pH for the growth was 10. The algal concentration of 1.1 g/l was attained after 8 days of growth at the optimum condition with the removal of 95% ammonia nitrogen and 34% phosphorus.

  • PDF

Electrosorption of Uranium Ions in Liquid Waste

  • Lee, Hye-Young;Jung, Chong-Hun;Oh, Won-Zin;Park, Jin-Ho;Shul, Yong-Gun
    • Carbon letters
    • /
    • 제4권2호
    • /
    • pp.64-68
    • /
    • 2003
  • A study on the electrosorption of uranium ions onto a porous activated carbon fiber (ACF) was performed to treat uraniumcontaining lagoon sludge. The result of the continuous flow-through cell electrosorption experiments showed that the applied negative potential increased the adsorption kinetics and capacity in comparison to the open-circuit potential (OCP) adsorption for uranium ions. Effective U(VI) removal is accomplished when a negative potential is applied to the activated carbon fiber (ACF) electrode. For a feed concentration of 100 mg/L, the concentration of U(VI) in the cell effluent is reduced to less than 1 mg/L. The selective removal of uranium ions from electrolyte was possible by the electrosorption process.

  • PDF

Ethylene Glycol과 Terephthalic Acid 분해균주를 이용한 감량가공폐수처리 (Treatment of Polyester Weight Loss Wastewater Using Strains Degrading Ethylene Glycol and Terephthalic Acid)

  • 서승교
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.43-48
    • /
    • 2001
  • Terephthalic acid and ethylene glycol resulting form the weight-reduction process of polyester make trouble in the operation of activated sludge process. Also, polyester weight loss wastewater shows high pH, high organic strength and wide variation of organic loading. Therefore, this study was conducted in order to improve treatment efficiency by activated sludge process with Pseudomonas sp degrading components of polyester weight loss wastewater. The CO $D_{Mn}$ and BO $S_{5}$ of the waste wastewater were 560~3,000 mg/$\ell$ and 8000~3,000 mg/$\ell$, respectively. pH was 11.8~12.3. COD removal efficiency by activated sludge-coagulation process with Pseudomonas sp was 94.1~95.8% for 35 hr of hydraulic retention time. Total organic carbon removal efficiency was 97.1%. Ethylene glycol and terephthalic acid in the wastewater were completely degraded during 32 hr of hydraulic retention time.e.

  • PDF

급속여과공정에서 여과수질 저하원인 및 개선방안 (Cause of Filtrate Deterioration and Its Improvement in Rapid Filtration)

  • 김진근;이송희;김재원
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.333-339
    • /
    • 2010
  • Particle removal is an important step taken at water treatment plants (WTPs) for the safety of tap water due to its proportionality to the pathogen inactivation. Government promulgated a treatment technique for the optimization of filtration including continuous turbidity monitoring using on-line turbidimeters. Based on the turbidity measurements of 460 filters at 31 WTPs operated by K-water, the evaluation of filtration performance and the investigation of major causes related to particle breakthrough were explored. 98.1 % of the filters had an effluent turbidity measurement which was less than 0.1 NTU, but turbidity breakthrough of more than 0.3 NTU was noticed occasionally which is in violation of AWWA 5-Star guidelines. It was shown that the optimization of coagulation, filter-to-waste, the observance of optimal filtration velocity and backwashing process based on filtrate turbidity were crucial for the improvement of filtrate.

화학적 및 생물학적 연속 처리에 의한 플루오렌 오염토양의 정화 (Cleanup of Fluorene-Contaminated Soil by Continuous Chemical and Biological Treatment)

  • 이병대
    • 한국환경보건학회지
    • /
    • 제37권2호
    • /
    • pp.159-164
    • /
    • 2011
  • We describe a method for effectively pretreating soil highly that has been contaminated with fluorene (${\gg}$ 120 mg/kg soil), i.e., we apply Fenton oxidation in which ethanol is added to increase fluorene removal. To obtain maximum fluorene removal efficiency, a minimum of 1.0 ml of ethanol, 0.35 ml of $H_2O_2$, and 0.2 ml of 0.5M $Fe^{2+}$ was needed per 1 g of fluorene-contaminated soil. Under optimal Fenton oxidation conditions, 13% of 9-fluorene was generated during Fenton oxidation of 43% fluorene. The biodegradability of 9-fluorenone was subsequently confirmed to be much more rapid than that of fluorene, i.e., biodegradability of 96% versus 35% over 31 days. These results demonstrate that the proposed treatment method can be effectively applied to remove fluorene prior to disposal at industrial waste sites.

Treatment of Starch Wastewater by Anaerobic Digestion Combined with Hollow Fiber UF

  • 노성희;나재운;김선일
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.745-748
    • /
    • 2000
  • Anaerobic digester coupled with hollow fiber membrane unit. Treatment of starch waste with anaerobic digester-membrane system was studied. $0.17\;m^2$ area of hollow fiber membrane unit of known pore size was immersed into laboratory-scale anaerobic digestion system. The gas production was about $0.74\;m^3/kg$ COD treated. The COD removal efficient was about 80-95% depending on the hydraulic retention time. Crossflow ultrafiltration as Post treatment to anaerobic filter. The study conducted with different membrane pore size indicated that membrane with 1,000,000 molecular weight cut-off size gave a higher COD removal efficiency in the range of 83-87% while giving a study flux of $120-130\;L/m^2\;{\cdot}\;h$. A study was conducted to see the long term clogging effect of membrane also.

  • PDF

Characteristics of arsenic sorption on furnace slag in groundwater

  • S. R. Kanel;Saurabh Sharma;Park, Hechul
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.96-98
    • /
    • 2002
  • Furnace slag, a steel industry waste, has been converted into an inexpensive and efficient adsorbent. The product obtained has been utilized for the removal of arsenic from ground water. Kinetic studies have bepn described with the mechanism of adsorption The results from batch studies showed that the As(III) can be removed from the ground water within the pH range 3-7 However the maximum removal was experienced at pH 7.0. Equilibrium was attained within 24 hours. Adsorption data of arsenic correlate well with the Freundlich and Langmuir adsorption models. The maximum sorption capacity as calculated using Freundlich adsorption isotherm was found to be of 0.004 mg g-1 at pH 7 and $25^{\circ}C$.

  • PDF

경량기포콘크리트를 이용한 인과 질소 및 음이온계면활성제 제거 (Removing of Phosphate, Nitrogen and Anion surfactants in the Wastewater using ALC)

  • 홍영호
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.102-107
    • /
    • 2001
  • This research was carried out investigate the removed T-P, T-N and anion surfactants using Autoclaved Lightweight Concrete(ALC) in wastewater treatment system. Effects of pH, TDS on aqueous solution was measured. Specific area which measured by BET was $27.66m^2/g$. The phosphorous, nitrogen and anion surfactants removal efficiencies were examined by using artificial waste water(T-P : 66~73mg/L, T-N : 56~136mg/L and anion surfactants : 10~31mg/L). The results showed that the ALC was effective material as a adsorbent due to the structure and porosity. It was found that anion surfactants removed was 85~95%, phosphate removed was 92% and nitrogen removed was 90% in artificial wastewater. Agitation process was more effective than aeration process in that case of nitrogen removal system using ALC.

  • PDF

칼슘과 마그네슘염을 이용한 염색폐수의 응집처리 (Treatment of Dyeing Wastewater by Flocculation with Calsium and Magnesium salts)

  • 김재용;서완주
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.89-98
    • /
    • 2002
  • The changes of conventional clarification process and an increase in treatment cost are required to meet increasingly stringent regulations related to the treated water quality. Although many enhanced coagulations have introduced to improve organic matter removal, the results to remove color, nitrogen and phosphorus as well as organic material have not been very efficient yet. The removal of waste matters such as SS, organic matter, color and turbidity contained in dyeing wastewater was carried out by using the combination of calcium hydroxide and magnesium sulfate. The flocculation was investigated as a function of coagulant dose, pH, mixing time, settling time and coagulant addition modes such as the sequential addition of the two coagulants and the simultaneous addition of them. The flocculation by the combination of calcium hydroxide and magnesium sulfate was compared with that by aluminum sulfate. The mechanism of flocculation was investigated as well. About 84% of color in dyeing watewater was removed by flocculation with combination of calcium hydroxide and magnesium sulfate.