• Title/Summary/Keyword: Waste Facilities

Search Result 763, Processing Time 0.025 seconds

Current Status and Future of Vermicomposting Industries in Korea (지렁이 퇴비화 산업 현황 및 향후과제)

  • Kim, Jong-Oh;Lee, Chang-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.2
    • /
    • pp.52-57
    • /
    • 2001
  • ln this study, the questionnaire survey was performed to obtain the basic data on current situations and challengeable aspects of vermicomposting industries. The questionnaire contained the four main categories such as vermicomposting facilities, feeling marerials, earthworm breeding and cast handling. The results was summarized as followings: 1. Vermicomposting facilities area was becoming larger, and earthworm feed was also expending to various organic sludges. These trends showed that Vermicomposting is being enlightened to treat and recycle the organic wastes in Korea. 2. Present Vermicomposting technology needs the broad land. Because of the high cost of land in Korea, the land saving technology such as multistage must be needed. And present operation practices are mostly based on human power, mechanization and automation is needed. Also, present control practices are based on individual experience need the scientific base control system. 3. Considering situations of organic wastes management in Korea, the technical development and the practical improvement of Vermicomposting as the waste recycling will be needed.

  • PDF

Development and Its Application of a Discrete Fracture Flow Model for the Analysis of Gas-Water Transient Flow in Fractured Rock Masses Around Storage Cavern (지하저장공동 주변 불연속 암반에서의 가스-물 천이유동해석을 위한 개별균열 유동모델의 개발 및 응용)

  • 나승훈;성원모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.705-712
    • /
    • 2000
  • The fluid generally flows through fractures in crystalline rocks where most of underground storage facilities are constructed because of their low hydraulic conductivities. The fractured rock is better to be conceptualized with a discrete fracture concept, rather continuum approach. In the aspect of fluid flow in underground, the simultaneous flow of groundwater and gas should be considered in the cases of generation and leakage of gas in nuclear waste disposal facilities, air sparging process and soil vapor extraction for eliminating contaminants in soil or rock pore, and pneumatic fracturing for the improvement of permeability of rock mass. For the purpose of appropriate analysis of groundwater-gas flow, this study presents an unsteady-state multi-phase FEM fracture network simulator. Numerical simulation has been also conducted to investigate the hydraulic head distribution and air tightness around Ulsan LPG storage cavern. The recorded hydraulic head at the observation well Y was -5 to -10 m. From the results obtained by the developed model, it shows that the discrete fracture model yielded hydraulic head of -10 m, whereas great discrepancy with the field data was observed in the case of equivalent continuum modeling. The air tightness of individual fractures around cavern was examined according to two different operating pressures and as a result, only several numbers of fractures neighboring the cavern did not satisfy the criteria of air tightness at 882 kPa of cavern pressure. In the meantime, when operating pressure is 710.5 kPa, the most areas did not satisfy air tightness criteria. Finally, in the case of gas leaking from cavern to the surrounding rocks, the resulted hydraulic head and flowing pattern was changed and, therefore, gas was leaked out from the cavern ceiling and groundwater was flowed into the cavern through the walls.

  • PDF

Evaluation of horizontal position Accuracy of Facilities in Digital Map (수치지도 상에 있는 시설물들에 대한 수평위치 정확도 평가)

  • Choi, Seung-Pil;Yang, In-Tae;Cho, Jee-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.4 s.22
    • /
    • pp.95-103
    • /
    • 2002
  • The accuracy of Digital Map does not meet the user's expectation, including the many errors caused while producing the project, this will be useless resulting waste of enormous national budget. To solve this Accuracy problem, clear regulations about the position accuracy of scaled Digital Map should be set immediately and provide the users with accurate information about Digital Map enabling the users to use Digital Map for each GIS application field. For this reason, the position accuracy evaluation of existing Digital Maps produced in diverse methods is on demand. In this study, therefore, we performed horizontal position survey of local selected Facilities Total Station equipment to evaluate the horizontal position accuracy of 1:1,000, 1:5,000 scaled Digital Map, obtained standard deviation using the results, performed T-Test to confirm the presence of bias and evaluated the position accuracy of Digital Map.

  • PDF

Optimal Design of Cogeneration System for General Facilities Considering LCC Analysis (LCC 분석을 고려한 일반 시설물에서 소형열병합발전의 최적 설계)

  • Kang, Yul-Ho;Ku, Bon-Cheol;Hwang, Yu-Jin;Song, Jae-Do;Cheong, Seong-Ir;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.439-447
    • /
    • 2009
  • Cogeneration system produces power as well as heat recovered from waste heat during power generation process. This system has higher energy efficiency than that of the power plant. In this study the optimal design for the cogeneration system with the increase of the capacity considering life cycle cost(LCC) analysis has been performed in the general facilities such as hotels and hospitals under the assumption of electricity cost of 95 won/kWh, the initial cost of cogeneration system of 1,500,000 won!kW and the value of 0.5${\sim}$1.0 in the ratio of heat to power. The optimal ratio of cogeneration capacity divided by average electricity load of facility was found out more than 0.5 in case of electricity cost with the increase of>30%, and the percentage of $CO_2$ reduction was about 9%. The most important factors in the economic analysis of cogeneration system was found out the electrity cost and the initial cost of cogeneration system. Also the ratio of heat to power at the value of>0.5 was not affected in the economy of cogeneration system, but was very important in the $CO_2$ reduction.

THE EFFECTS OF OPERATIONAL AND FINANCIAL FACTORS ON THE ECONOMICS OF BIOGAS PRODUCTION FROM DAIRY COW FECES AND WASTEWATER

  • Kobayashi, S.;Masuda, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.1
    • /
    • pp.139-145
    • /
    • 1993
  • Biogas created from animal waste is a precious energy source. A practical and successful utilization of the biogas is not easy, because there lie some difficulties in biogas production and facilities investment. In this study, the requisites for a successful biogas utilization were discussed. The production results obtained in the previous operation of anaerobic digestion plant were used for the simulation. When the slurry heating was designed for constant biogas generation, depreciation costs of the facilities amounted 1,175,000 yen per year, and biogas productions at $24.5^{\circ}C$, $30.0^{\circ}C$ and $35.5^{\circ}C$ were $16.8m^3$, $17.6m^3$ and $25.1m^3$, respectively. Removal ratios of organic matters were not so high. At $35.5^{\circ}C$, energy value of the biogas produced was estimated 125.5 Mcal per day, and the following heat loss (y Mcal/day) was brought about by the temperature difference ($X^{\circ}C$) between the digester and atmosphere; y = 0.769X - 5.375. The costs of biogas production per cow were assumed to decrease according to enlargement of feeding scale, especially on scales of more than 30 cows. On recent levels of costs and prices of energy in Japan, they were nearly equal to 2 to 3 fold of the price of municipal mixed gas when a anaerobic digester was compulsorily heated and kept at $30.0^{\circ}C$ or $35.5^{\circ}C$.

Development of WIPI-based Artificial Reefs Search Contents (WIPI기반 인공어초 검색 콘텐츠 개발)

  • Kwak Ho-Young;Han Kyoung-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.238-247
    • /
    • 2005
  • The development of IT related technology has made it possible to offer 'Any Time, Any Where, Any Service' to the users and internet-based service became accessible while on the move through wireless internet service. Moreover, the development of various wireless contents has been provided diverse ioy and convenience to life. However, the existing wireless contents had been subordinate to the wireless internet platform because it had not been set up for a standardized environment. Therefore, repeated developments of contents have been causing waste of resource, time and manpower. This paper aims at suggesting WIPI-bases artificial reefs search contents which have become independent from platform by using JAVA. Artificial reefs facilities are a government project for increasing the revenue of fishermen but only few fishermen know the information about the location of artificial reefs and most of them are not aware of the location of these facilities. There(ore this thesis plans to develop WIPI-bases artificial reefs search contents to provide information such as the location, the depth, and the bottom material to anglers and those fishermen who do not know the location of artificial reefs so that the fishermen can have the opportunity to increase their revenue and also the opportunity to catch a big fish for anglers.

  • PDF

Mercury Emission Control in Japan

  • Takiguchi, Hiroaki;Tamura, Tomonori
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.37-46
    • /
    • 2018
  • The Minamata Convention on Mercury entered into force on August 16, 2017. It requires Parties to the Convention to control and, where feasible, reduce mercury emissions from the listed sources. To implement the Convention, Japan amended the Air Pollution Control Law and added clauses that force operators to control their mercury emissions below emission limit values (ELVs). The ELVs have been established separately for new and existing sources, targeting the source categories listed in the Convention: coal-fired boilers, smelting and roasting processes used in the production of non-ferrous metals (lead, zinc, copper and industrial gold), waste incineration facilities and cement clinker production facilities. The factors used to establish the ELVs include the present state of mercury emissions from the targeted categories as well as the mercury content in fuels and materials, best available techniques (BATs) and best environmental practices (BEPs) to control and reduce mercury emissions and ELVs or equivalent standards to control mercury emissions in other countries. In this regard, extensive data on mercury emissions from flue gas and the mercury content of fuels and materials were collected and analyzed. The established ELVs range from $8{\mu}g/Nm^3$ for new coal-fired boilers to $400{\mu}g/Nm^3$ for existing secondary smelting processes used in the production of copper, lead and zinc. This paper illustrates the ELVs for the targeted source categories, explaining the rationales and approaches used to set the values. The amended Law is to be enforced on April 1, 2018. From future perspectives, checks of the material flow of mercury, following up on the state of compliance, review of the ELVs and of the measurement and monitoring methods have been noted as important issues.

A Study on the Passive House Technology Application of University Dormitory through The House at Cornell Tech (코넬 공과대학 기숙사 사례를 통한 대학 기숙사의 패시브 하우스 기술 적용에 관한 연구)

  • Kim, Hong-Min;Oh, Hyoung-Seok;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.4
    • /
    • pp.11-18
    • /
    • 2018
  • Global warming is happening now and inevitable. Everyone knows that immediate action should be taken to slow it down, but uncertain about the effective solution. Despite global efforts to reduce greenhouse gas emissions, sea levels are rising gradually. In 2013, Cornell University announced the Climate Action Plan(CAP) to make the campus greener, to reduce waste, and to ensure efficient use of resources. In particular, they set a goal of reducing energy use by 2050 and making carbon emissions to zero. Accordingly, the purpose of this study is to analyse the case of the master plan of Cornell Tech campus and its major buildings. Mainly, The House, faculty and student housing of Cornell Tech and the world tallest certified passive house, will be the main precedent that shows the architectural planning of passive house. Passive house technology, which was thought to be possible only in single-family houses, can be applied to high-rise buildings. If any passive house technology of The House project is actively introduced into the dormitory projects of domestic universities that are about to be built or renovated, it will be a good opportunity for the university to take the lead in preparing for global warming.

Activation Reduction Method for a Concrete Wall in a Cyclotron Vault

  • Kumagai, Masaaki;Sodeyama, Kohsuke;Sakamoto, Yukio;Toyoda, Akihiro;Matsumura, Hiroshi;Ebara, Takayoshi;Yamashita, Taichi;Masumoto, Kazuyoshi
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.3
    • /
    • pp.141-145
    • /
    • 2017
  • Background: The concrete walls inside the vaults of cyclotron facilities are activated by neutrons emitted by the targets during radioisotope production. Reducing the amount of radioactive waste created in such facilities is very important in case they are decommissioned. Thus, we proposed a strategy of reducing the neutron activation of the concrete walls in cyclotrons during operation. Materials and Methods: A polyethylene plate and B-doped Al sheet (30 wt% of B and 2.5 mm in thickness) were placed in front of the wall in the cyclotron room of a radioisotope production facility for pharmaceutical use. The target was Xe gas, and a Cu block was utilized for proton dumping. The irradiation time, proton energy, and beam current were 8 hours, 30 MeV, and $125{\mu}A$, respectively. To determine a suitable thickness for the polyethylene plate set in front of the B-doped Al sheet, the neutron-reducing effects achieved by inserting such sheets at several depths within polyethylene plate stacks were evaluated. The neutron fluence was monitored using an activation detector and 20-g on de Au foil samples with and without 0.5-mm-thick Cd foil. Each Au foil sample was pasted onto the center of a polyethylene plate and B-doped Al sheet, and the absolute activity of one Au foil sample was measured as a standard using a Ge detector. The resulting relative activities were obtained by calculating the ratio of the photostimulated luminescence of each foil sample to that of the standard Au foil. Results and Discussion: When the combination of a 4-cm-thick polyethylene plate and B-doped Al sheet was employed, the thermal neutron rate was reduced by 78%. Conclusion: The combination of a 4-cm-thick polyethylene plate and B-doped Al sheet effectively reduced the neutron activation of the investigated concrete wall.

Development of an Approximate Cost Estimating Model for River Facility Construction at Planning Stage (이.치수형 하천공사 개략공사비 산정모델 개발)

  • Lee, Si-Wook;Lee, Jeong-Yoon;Park, Sung-Hwan;Choi, Jae-Joon;Woo, Sung-Kwon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.5
    • /
    • pp.95-103
    • /
    • 2009
  • The case of rivers facilities works, expense the standard unit cost for the quality and a rough public corporation expense estimating of the rivers public corporation which is fixed form with the information available which it follows basic design phase absently and possibility of fluctuation. It exists many difficulties in rough public corporation expense estimating. The rivers public corporation expense rough estimating method of existing produces does not exist the amount of material of representative section of the rivers dike and the rough public corporation expense estimating method which is systematic with the method which multiples the seniority (M). The research sees the rough public corporation expense predictive model from the planning stage which is not basic design to consider the quality of the rivers facility public corporation. From this study, it can prevent the waste of national budget from the general public corporation and is more accurate and public corporation expense production possibly.