• Title/Summary/Keyword: Waste Facilities

Search Result 767, Processing Time 0.026 seconds

Treatment of Malodorous Waste Air Using Hybrid System (하이브리드시스템을 이용한 악취폐가스 처리)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.382-390
    • /
    • 2010
  • In this research hydrogen sulfide, ammonia and toluene were designated as the representative source of malodor and VOC, respectively, frequently generated at the compost manufacturing factory and publicly owned facilities. The optimum operating condition to treat the waste air(2 L/min) containing malodor was constructed using photocatalytic reactor/biofilter process with humidifier composed of fluidized aerobic anf anoxic reactor. The ammonia(300 ppmv) of fed-waste air was removed by 22, 55 and 23% at the stage of photocatalytic reactor, humidifier and biofilter, respectively. The toluene(100 ppmv) of fed-waste air was removed by 20, 10 and 70% at the stage of photocatalytic reactor, humidifier and biofilter, respectively. Therefore the water-soluble ammonia and the water-insoluble toluene were treated mainly at the stage of humidifier and biofilter, respectively. In addition, hydrogen sulfide(10 ppmv) was almost treated at the stage of photocatalytic reactor and its negligible trace was absorbed in humidifier so that it was not detected before biofilter process. The nitrate concentration of the process water from anoxic reactor was found lower by 3 ppm than that from fluidized aerobic reactor. Besides, the dissolved ammonia-nitrogen concentration of the process water from humidifier remained at the high value of 1,500-2,000 ppm, which may be attributed to the existence of ammonium chloride and other source of ammonium nitrogen.

Environmental Health Strategies in Korea (우리 나라의 환경정책 방향)

  • 조병극
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.1-10
    • /
    • 1992
  • Since 1960's along with industrialization and urbanization, economic growth has been . achieved, however, at the same time, environmental condition has been seriously deteriorated. . Currently, volume of wastewater has been increasing at annual rate of 7% in sewage and 20% in industrial wastewater. However, the nation's sewage treatment serves only 33% of the municipal wastewater as of 1991. Major portion of air pollutants comes from combustion of oil and coal which comprise 81% of total energy use and emission gases from motor vehicles increasing at an accelerated rate. It is known that Korea generates the highest amount of waste per capta. Nevertheless, it is not sufficient to reduce the volume of waste by means of resources recovery and recycling. Recognizing the importance of global environmental problems such as ozone layer depletion, global warming and acid rain, international society has been making various efforts since the 1972 Stockholm conference. In particular, it is expected that the Rio conference which has adopted the Rio declaration and Agenda 21 will form a crucial turning point of the emerging new world order after the Cold War confrontation. To cope with such issues as domestic pollution and global environmental problems, the fundamental national policy aims at harmonizing "environmental protection and sustainable development". The Ministry of Environment has recently set up a mid-term comprehensive plan which includes annual targets for environmental protection. According to the government plan, gradual improvement of various environmental conditions and specific measures to achieve them is planned in time frame. Additional sewage treatment plants will be constructed in urban areas with the target to treat 65% of the nation's municipal sewage by 1996. Supply of clean fuels such as LNG will also be expanded starting from large cities as a cleaner substitute energy for coal and oil. In parallel with expansion of LNG, emphasis will be placed on installation of stack monitoring system. Due to the relatively limited land, government's basic policy for solid waste treatment is to develop large scale landfill facilities rather than small sized ones. Thirty three regional areas have been designated for the purpose of waste management. For each of these regions, big scale landfill site is going to be developed. To increase the rate of waste recycling the government is planning to reinforce separate collection system and to provide industries with economic incentives. As a part of meeting the changing situation on global environmental problems after UNCED, and accommodation regulatory measures stipulated in the global environmental conventions and protocols, national policy will try to alter industrial and economic structure so as to mitigate the increasing trends of energy consumption, by encouraging energy conservation and efficiency. In this regard, more attention will be given to the policy on the development of the cleaner technology. Ultimately, these policies and programs will contribute greatly to improving the current state of national public health.

  • PDF

The Evaluation of Minimum Cooling Period for Loading of PWR Spent Nuclear Fuel of a Dual Purpose Metal Cask (국내 경수로 사용후핵연료의 금속 겸용용기 장전을 위한 최소 냉각기간 평가)

  • Dho, Ho-Seog;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.411-422
    • /
    • 2016
  • Recently, because the wet pool storage facilities of NPPs in Korea has become saturated, there has been much active R&D on an interim dry storage system using a transportation and storage cask. Generally, the shielding evaluation for the design of a spent fuel transportation and storage cask is performed by the design basis fuel, which selects the most conservative fuel among the fuels to be loaded into the cask. However, the loading of actual spent fuel into the transportation metal cask is not limited to the design basis fuel used in the shielding evaluation; the loading feasibility of actual spent fuel is determined by the shielding evaluation that considers the characteristics of the initial enrichment, the maximum burnup and the minimum cooling period. This study describes a shielding analysis method for determining the minimum cooling period of spent fuel that meets the domestic transportation standard of the dual purpose metal cask. In particular, the spent fuel of 3.0~4.5wt% initial enrichment, which has a large amount of release, was evaluated by segmented shielding calculations for efficient improvement of the results. The shielding evaluation revealed that about 81% of generated spent fuel from the domestic nuclear power plants until 2008 could be transported by the dual purpose metal cask. The results of this study will be helpful in establishing a technical basis for developing operating procedures for transportation of the dual purpose metal cask.

A Study on the Characteristics and Distribution of the Time-Spatial Occurrence of Offensive Odors -Gangwon Province - (악취의 시공간적 발생 특성 및 분포도 분석 - 강원지역을 대상으로 -)

  • Kim, Byoung-Ug;Hyun, Geun-Woo;Bae, Sun-Hak;Hong, Young-Kyun;Lee, Yeong-Seob;Yi, Geon-Ho;Huh, In-Ryang;Choi, Seung-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.4
    • /
    • pp.376-387
    • /
    • 2020
  • Objectives: This study is aimed at offering basic data for making plans for offensive odor management after researching offensive odor occurrence and characteristics in Gangwon Province. Methods: The data used in the study is based on offensive odor data analyzed by the Gangwon Institute of Health and Environment from 2012 to 2019. The data were reclassified by year, month, facility, and region to identify characteristics of occurrence. Finally, a distribution map of offensive odors was created using ArcGIS. Results: The highest monthly frequency of offensive odor occurrence falls in June, August, and July, and the summer season and third quarter are the highest. According to the latest eight-year data for Gangwon Province, complaints about offensive odors in county areas are more frequent than those in city areas. There are many offensive odor complaints in Wonju, Cheorwon, and Heongsung. The main offensive odor emission facilities are livestock and waste treatment (recycling) facilities. Complaints about offensive odors are relatively lower the Yeongdong area than Yeongseo area, which is considered to be the result of characteristics of land-sea breezes and geographical factors. Offensive odors from livestock facilities count for an average of 53.9% of the total, and the inadequacy rate of livestock facilities averages 36.9%. Conclusions: To maintain a clean environment in Gangwon Province, it is strongly recommended that an offensive odor reduction plan for livestock facilities be established. Areas with a high density of offensive odor occurrence should be identified and systematically managed with short- and mid-term measures. If offensive odors is managed using GIS, it is possible to identify the characteristics of occurrence by time and space and also by facility. In addition, since systematic data management is possible, it is believed that a rapid response to offensive odors, prediction of their spread, and efficient management are possible.

The Economic Effects of the Expanding Manufacture and Utilization of Solid Refuse Fuel (SRF) Facilities in Korea : An Input-output Analysis (SRF 제조·활용 시설 확대의 경제적 파급효과 분석)

  • Cho, Yongcheol;Park, Soyeon;Yoo, Seunghoon
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.95-103
    • /
    • 2016
  • The government is trying to expanding the manufacture and utilization of solid refuse fuel (SRF) facilities in order to mitigate greenhouse gases reducing and eco-friendly waste-to-energy recovery. In this regard, this study attempts to look into the economic effects of expanding the manufacture and utilization of SRF facilities by applying an inter-industry analysis using a 2014 input-output table. Specifically, by applying the demand-driven model presents the results for the production-inducing effect, value-added creation effect, and employment-inducing effect. In particular, this study attempted to redefine for the SRF. In addition, it was accessed by exogenous around the manufacture and utilization of SRF sector. The results show that production-inducing effect and value-added creation effect of expanding the manufacture and utilization of SRF facilities for the investment of 1.0 won are estimated to be 1.9993 and 0.6747, respectively. The employment-inducing effect of one billion of investment in the expanding the manufacture and utilization of SRF facilities is computed to be 11.1982 persons. This information can be utilized in predicting the economic effects of the manufacture and utilization of SRF.

A Study on Influencing Factors to build a Counter-Drone system : Focusing on national important facilities (대(對)드론(Counter-Drone)체계 구축을 위한 영향요인 분석 -국가중요시설을 중심으로-)

  • Nam-Il Lee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.483-494
    • /
    • 2024
  • This study is a study on influencing factors to derive considerations when establishing a large drone integrated protection system targeting important national facilities. Currently, drone protection is implemented by piecemeal installation of drone protection equipment developed on the market in response to the needs of government agencies, the military, and national important facilities. For this reason, there is a waste of resources, such as duplicate installation or overlapping operation of equipment, and institutional and legal problems between operations are emerging. Accordingly, we sought to identify factors influencing the establishment of an efficient and systematic anti-drone protection system targeting national important facilities. Considering the research purpose and scope, this study derived 3 influencing factors and 12 detailed influencing factors through case analysis, protection theory research, and analysis of related laws. If the results of this study are used as considerations when building an integrated anti-drone protection system in the future, all national defense elements will be integrated and systematic integrated anti-drone protection will be possible according to their respective roles. In addition, it will provide a theoretical foundation for building an integrated anti-drone protection system. The results of this study are valuable in that they present logical and systematic influencing factors for establishing an integrated anti-drone protection system.

A Study on the Estimation Method of the Repair Rates in Finishing Materials of Domestic Office Buildings (국내 업무시설 건축 마감재의 수선율 산정 방안에 관한 연구)

  • Kim, Sun-Nam;Yoo, Hyun-Seok;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.52-63
    • /
    • 2015
  • Business facilities among domestic architectures have rapidly been constructed along with domestic economic development. It is an important facility taking the second largest proportion next to apartment buildings among current 31 building types of fire department classification of 2012 year for urban architectures. The expected service life of business facilities is 15 years, but 70% of those in urban areas have surpassed the 15 year service life as of the present 2014. Thus, the demand for urgent rehabilitation of such facilities is constantly increasing due to the aging and performance deterioration of the facilities'main finishing materials. Especially, the business facilities are being used for the lease of company office or private office, and such problems as aging and performance deterioration of the facilities could cause less competitive edge for leasing and real estate value depreciation for the O&M (Operation & Management) agent and the owner, respectively. Therefore, an effective planned rehabilitation as a preventive measure according to the standardized repair rate by the number of years after the construction is in need in order to prevent the aging and performance deterioration of the facilities(La et al. 2001). Nonetheless, domestic repair/rehabilitation standards based on the repair rate are mainly limited to apartment buildings and pubic institutions, resulting in impractical application of such standards to business facilities. It has been investigated and analyzed that annual repair rate data for each finishing material are required for examination of the applicability of the repair rate standard for the purpose of establishment of a repair plan. Hence, this study aimed at developing a repair rate computation model for finishing materials of the facilities and verifying the appropriateness of the annual repair rate for each finishing material through a case study after collecting and analyzing the repair history data of six business facilities. The results of this study are expected to contribute to the planning and implementation of more efficient repair/rehabilitation budget by preventing the waste of unpredicted repair cost and opportunity cost for the sake of the business facilities' owners and O&M agents.

Size Distribution and Physicochemical Characteristics of MSW for Design of Its Mechanical Biological Treatment Process (폐기물전처리(MBT)시설 설계를 위한 생활폐기물의 입도분포 및 물리화학적 특성에 관한 연구)

  • Park, Jin-Kyu;Song, Sang-Hoon;Jeong, Sae-Rom;Jung, Min-Soo;Lee, Nam-Hoon;Lee, Byoung-Chul
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2008
  • There has been a recent trend in Korea that treatments for combustible wastes among municipal solid waste (MSW) by those methods, such as incineration and landfill are restricted as much as possible and Mechanical Biological Treatment (MBT) are encouraged actively in order to promote resource recovery. To build and operate properly these facilities, the physicochemical characteristics of MSW should be analyzed precisely beforehand. In particular, designing a crusher or separator properly which is the main process in MBT facilities of MSW. require the information on the size distribution characteristics of MSW, but they are nor sufficient in the qualities and quantities yet as of now. Accordingly, this study aims to evaluate size distribution characteristics of MSW and its physicochemical characteristics by size. The samples of MSW were collected from detached dwelling area, apartment area, business area, and commercial area of A city in Korea. According to the result of analysis, paper records 29.78~60.02% by wet weight basis, so it was the most regardless of the regions where the wastes were generated. And in terms of element analysis, Carbon(C) was 34.77~44.39%, the largest friction, and Oxygen(O) was the next occupying 19.46~33.71%. As indices of RDFs, Chlorine(Cl) was 0.39~0.83%, so it was less than the standard, 2.0%(by dry weight basis); moreover, Sulfur(S) did not exceed the standard, 0.6%, either. In the size distribution of MSW, waste fraction ranging 50~80mm in diameter was the most in combustible waste while 30~50mm was in incombustible waste.

  • PDF

An Estimation of Quantity of Unused Energy of River Water, Seawater and Treated Sewage as Heat Source and Its Availability in Large Facilities (대규모 시설에서 이용가능한 미활용 에너지의 부존량과 그 이용 가능성에 관한 조사연구-하천수.해수.하수처리수를 중심으로)

  • Heo, Jae-Yeong
    • Journal of National Security and Military Science
    • /
    • s.1
    • /
    • pp.423-446
    • /
    • 2003
  • While the demand for energy has shown a sharp increase recently, the supply seems to be limited by the fact that the conventional fossil fuel energy or nuclear energy has its own environmental problems such as, for example, global warming or nuclear waste disposal. To overcome such limited supply of energy, the utilization of natural thermal energy such as river water and seawater as well as treated sewage can be a substantial supplement. The potential use of the unused energy has become more and more feasible these days as the heat pump technology has been advanced. In the present study, the unused energy resources are estimated on regional and monthly basis for each resource by the method proposed here in order to establish the fundamental data for its utilization. The potential use of the unused energy is a1so discussed.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF