• Title/Summary/Keyword: Warming Up

Search Result 302, Processing Time 0.027 seconds

Numerical Study on the Impact of Regional Warming on the Meterological Field and Ozone Concentration over the South-Eastern Part of the Korean Peninsula (기후변화에 따른 기온상승이 한반도 동남지역 국지 기상장과 오존 분포에 미치는 영향에 관한 수치모의)

  • Jeong, Yeo-Min;Lee, Hwa-Woon;Lee, Soon-Hwan;Choi, Hyun-Jung;Jeon, Won-Bae
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1431-1445
    • /
    • 2010
  • In order to clarify the impact of regional warming on the meteorological field and air quality over southeastern part of Korean Peninsula, several numerical experiment were carried out. Numerical models used in this study are WRF for the estimate the meteorological elements and CMAQ for assessment of ozone concentration. According to the global warming impact, initial air temperature were changed and its warming rate reach at 2 degree which was based on the global warming scenarios provided by IPCC. The experiments considering the global warming at initial stage were presented as case T_UP. Air temperature over inland area during night time for case T_UP is higher than that for Base case. During time since the higher temperature over inland area is maintained during daytime more intensified sea breeze should be induced and also decrease the air temperature in vicinity of coast area. In case of T_UP, high level concentrations ozone distribution area was narrowed and their disappearance were faster after 1800LST. As a results, wind and temperature fields due to the global warming at initial stage mainly results in the pattern of ozone concentration and its temporal variation at South-Eastern Part of the Korean Peninsula.

Study on the Temperature Variation of Greenhouse Soil Warming using the Solar Energy(1) - Temperature Variation of Soil Depth by Soil Warming - (태양열을 이용한 시설재배 지중변온가온의 토양 온도특성 연구(1) - 지중변온가온에 따른 깊이별 온도특성 -)

  • Kim, J.H.;Kim, T.W.;Nah, K.D.;Kim, T.S.;Sung, I.J.;Chung, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.3
    • /
    • pp.190-196
    • /
    • 2009
  • The temperature of root zone is known as an important factor for the growth of crops and reduction of energy in greenhouse. The purpose of this study was to design the solar energy supply system to keep the optimum condition of root zone by soil warming. As a result of this study, soil warming compared with no warming changed on a large scale temperature rise effect by depth of soil. The greenhouse's inner temperature have an effect on the temperature of surface up to 15 cm, rised to about 1 hour after warming. In case of the temperature fluctuation, soil temperature was about $12^{\circ}C$ up to 15${\sim}$25 cm and it was $13.4^{\circ}C$ at greater depths. This results showed that the position of root zone was very different after 3 weeks of growth.

A Study on Inlet Pressure Build-up of Air-Lubricated Bearings (공기베어링에서의 선단압력발생에 관한 연구)

  • 김성국;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.127-132
    • /
    • 1999
  • The inlet pressure build-up at the leading edge of bearings which have discontinuous lubrication surface is analyzed theoretically. The analyses of Inlet pressure build-up is obtained by means of full Navier-stokes equations. Beam-warming method is used to solve navier-stokes equations. The results show that inlet pressure is above atmosphere pressure in front of leading edge of hearing.

  • PDF

Urbanization Effect on the Observed Warming in Korea during the Recent Half Century (우리나라의 기온상승-도시효과인가 지구온난화인가)

  • 윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.1
    • /
    • pp.58-63
    • /
    • 2002
  • Since the rapid urbanization period coincides with the start of global warming, climate data might be contaminated with urbanization effect in Korea. Monthly normals of daily minimum, maximum, and mean temperature of 14 stations were calculated for 1951-1980 and 1971-2000 periods. Differences in two temperature normals were regressed to the natural logarithms of population increase at corresponding 14 cities from 1966 to 1990. The regression models were used to remove potential effects of urbanization from the apparent warming, and to determine the net contribution of global warming to the temperature change in Korea during the recent half century. According to the model calculation, there was little evidence of global warming in the warm season (May through November), while urbanization effect was common in all season except April. Up to 0.5$^{\circ}C$ warming of nighttime temperature was found to be induced by urbanization. Cool season temperature was increased by up to 0.6$^{\circ}C$ due mainly to the global warming of daytime temperature.

The Effect of Warming Patients Before or During the Surgical Operations on the Patients' Body Temperature and Shivering (수술전 가온과 수술중 가온이 수술환자의 체온과 전율에 미치는 영향)

  • Lee, Ji-Yeon;Lee, Hyang-Yeon
    • Korean Journal of Adult Nursing
    • /
    • v.14 no.3
    • /
    • pp.428-437
    • /
    • 2002
  • Purpose: The purpose of this study is to examine the changes of surgical patients' body temperature in applying warming to patients. The study of an effective nursing intervention, which aims to prevent hypothermia during surgical operations, use of anesthesia, and to remove dermal discomforts. The nonequivalent control group pre-test/post-test design was used for this quasi-experimental study. Method: The study subjects were adult patients who would take a surgical operation under general anesthesia in C Hospital; the surgical operations done were, total abdominal hysterectomy or Myomectomy; 20 patients were included in experimental group I, 20 patients were included in experimental group II, and 20 patients were in the comparative group. The total number of study subjects was 60. The data was collected from September the 1st, 2001 to October the 20th, 2001. The data was analyzed by SPSS program, F-test and Repeated measures of ANOVA. Multi-comparison method of DUNCAN was used for the sections that show the significant differences at the level of p<.05, which was a posterior examination. Result: 1) "The body temperatures of the three groups of patients will be respectively different at the end of the operations; experimental group I to which warming was applied before the operations, experimental group II to which warming was applied during the operations, and the comparative group with no warming being given," showed (F=12.609, p=.000). 2) "Degrees of shivering symptoms for the three groups will be respectively different at the end of the operations; experimental group I which applied warming before operations, experimental group II which applied warming during operations and the comparative group with no warming." Showed assumed (F=6.626, p=.000). Conclusion: Summing up the above study, the warming assumed during operations was a more effective nursing intervention for preventing patients' hypothermia than the warming assumed before operations.

  • PDF

Effects of Forced Air Warming on Body Temperature, Shivering and Pain in Laparoscopic Cholecystectomy Patients (공기가온요법이 복강경 담낭절제술 환자의 체온, 전율 및 통증에 미치는 효과)

  • Park, Sung Joo;Kim, Sook Young
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.22 no.3
    • /
    • pp.287-296
    • /
    • 2015
  • Purpose: The purpose of this study was to examine the effects of forced air warming on intraoperative and postoperative body temperature, postoperative shivering and pain in patients undergoing laparoscopic cholecystectomy. Methods: A quasi-experimental design with nonequivalent control group was utilized. Fifty eight patients scheduled for laparoscopic cholecystectomy were recruited and assigned to the experimental group (n=29) or control group (n=29). For the experimental group, forced air warming was applied from right after induction and up to one hour after surgery. Body temperature, shivering score and pain score were measured in both groups at 15 minute intervals. Data were collected from September, 2013 to April, 2014. Data were analyzed using t-test, Bonferroni test and repeated measures ANOVA. Results: The experimental group showed higher body temperature than the control group during surgery. After surgery the experimental group showed higher body temperature, lower shivering and less pain compared to the control group. Conclusion: Results show that forced air warming is effective in enhancing body temperature and reducing shivering and pain. Therefore, forced air warming is recommended as an operative nursing intervention.

Effects of Warm-up Performance on SI Engine with Exhaust Heat Recovery System (배기열 회수장치 적용에 따른 SI 엔진의 웜업 성능에 미치는 영향)

  • Park, Kyoun-Suk;Suh, Ho-Cheol;Park, Sun-Hong;Kim, In-Tae;Jang, Sung-Wook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.53-60
    • /
    • 2011
  • The effect of exhaust heat recovery system can be evaluated by two well known method. First method is to measure the time duration from engine start under cold coolant temperature till coolant get warmed. By this methodology coolant warming duration can be index of warm-up effect. Second method is to analyze heat balance of the engine during warm-up phase under steady engine operation so that wasted energy by losses such as cooling and exhaust can be index of warm-up effect. This study focused on evaluation of warming-up effect by both methodology above mentioned using 2L SI engine under from idle to 2000rpm steady condition. Results, idle operation showed low heat recovery efficiency but under higher engine speed condition, remarkable heat recovery efficiency improvement was observed. In 2000rpm steady condition, warm-up duration of engine is decreased by exhaust heat recovery system.

Emission Control Technologies for N2O from Adipic Acid Production Plants (아디픽산 제조공정으로부터 발생되는 N2O에 대한 배출제어기술)

  • Kim, Moon-Hyeon
    • Journal of Environmental Science International
    • /
    • v.20 no.6
    • /
    • pp.755-765
    • /
    • 2011
  • Nitrous oxide ($N_2O$) is one of six greenhouse gases listed up in the Kyoto Protocol, and it effects a strong global warming because of its much greater global warming potential (GWP), by 310 times over a 100-year time horizon, than $CO_2$. Although such $N_2O$ emissions from both natural and anthropogenic sources occur, the latter can be controlled using suitable abatement technologies, depending on them, to reduce $N_2O$ below acceptable or feasible levels. This paper has extensively reviewed the anthropogenic $N_2O$ emission sources and their related compositions, and the state-of-the-art non-catalytic and catalytic technologies of the emissions controls available currently to representative, large $N_2O$ emission sources, such as adipic acid production plants. Challengeable approaches to this source are discussed to promote establishment of advanced $N_2O$ emission control technologies.

Alternate Energy: Gravity Powered Rail Transportation Systems

  • Bojji, Rajaram
    • International Journal of Railway
    • /
    • v.2 no.1
    • /
    • pp.22-29
    • /
    • 2009
  • A simple pendulum shows how efficient gravity is in recovering energy. Any transportation is a linearly oscillating system; every load gains kinetic energy, but loses the same to come to a stop. The Gravity Power Towers comprise of a set of vertically moving heavy masses coupled, through microprocessor controlled continuously variable gear and cable system, to a horizontally rolling unit on wheels either on rail or road. The heavy masses move vertically up against gravity gaining potential energy while stopping a moving mass; move down under gravity force, giving out energy. The Tower thus accelerates or sustains the speed a rolling unit, and while decelerating, recover the kinetic energy. Speeds of 360 kmph can be attained. Recovery of energy varies from 98.5-70%; the longer the distance between stops, the lesser is recovery. The economical, omnipresent & eternal Gravity Power grants energy independence to many a nation. Global warming reduces.

  • PDF

Identification of Potential Environmental Impacts among Renewable Energy Technologies Promising to Minimize Global Warming (지구온난화 최소화를 위한 신재생 에너지들의 잠재환경영향)

  • Kim, Yong-Bum;Chung, Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.1
    • /
    • pp.67-79
    • /
    • 2008
  • Global warming, which is one of the most serious challenges, has been the subject of intense debate and concern for many scientists, policy-makers, and citizens for at least the past decade. To protect the health and economic well-being of current and future generations, we must reduce our emissions like carbon dioxide. Alternatives to achieve an energy future without serious global warming are to change to clean and renewable sources of energy like the wind, the sun lights, rivers, the biomass, hydrogen, and oceans. To identify some of the key and new environmental impacts associated with renewable energy and hydrogen energy, we set up the new conceptual methodology. Specifically, new identified environmental and health impacts are related with the usage of hydrogen energy. When comparing with fossil fuel, the renewable energies can reduce the release of carbon dioxide when they are used except hydrogen produced from fossil fuel. However, all renewable energy technologies are not appropriate to all applications or locations. Our results suggest that all of alternatives to replace fossil fuel can release the several global and local impacts although they seems to be smaller than the impacts from fossil fuel. Therefore, the quantitative and detail analysis to assess environmental impacts of the alternative energies might be useful to make our decision for the future energy against the global warming.