• Title/Summary/Keyword: Wall panel

검색결과 439건 처리시간 0.032초

Efficient membrane element for cyclic response of RC panels

  • Tesser, Lepoldo;Talledo, Diego A.
    • Computers and Concrete
    • /
    • 제20권3호
    • /
    • pp.351-360
    • /
    • 2017
  • This paper presents an efficient membrane finite element for the cyclic inelastic response analysis of RC structures under complex plane stress states including shear. The model strikes a balance between accuracy and numerical efficiency to meet the challenge of shear wall simulations in earthquake engineering practice. The concrete material model at the integration points of the finite element is based on damage plasticity with two damage parameters. All reinforcing bars with the same orientation are represented by an embedded orthotropic steel layer based on uniaxial stress-strain relation, so that the dowel and bond-slip effect of the reinforcing steel are presently neglected in the interest of computational efficiency. The model is validated with significant experimental results of the cyclic response of RC panels with uniform stress states.

경량 GFRP 패널을 이용한 하수관거공사용 복공 가시설 시스템의 개발 (Development of Lining-Board System Using Light-Weight GFRP Panels for Sewer-Pipe Construction)

  • 박신전;홍기증
    • 복합신소재구조학회 논문집
    • /
    • 제5권3호
    • /
    • pp.23-31
    • /
    • 2014
  • Recently, sewer-pipe constructions replacing deteriorated pipes are currently underway in the downtown area. To resolve many problems in the conventional method of open-cut construction, lining-board system using light-weight GFRP panels is developed. The pultruded GFRP panels can be successfully used for the developed lining-board system as temporary decks and retaining walls in virtue of light weight, high strength and high durability. In this paper, the structural safety and serviceability of the lining-board system are examined through FE analyses and experiments. Further more, a field application of the lining-board system is presented. The field application shows that quality and environment of construction can be significantly improved.

Reciprocal Sustain and Auxiliary Pulse Waveforms Applied to an AC PDP with an Auxiliary Electrode

  • Choi, Kyung-Cheol;Lee, Sung-Min;Choi, Chung-Sock;Jang, Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1543-1546
    • /
    • 2008
  • Modified pulse waveforms were applied to an AC plasma display panel with an auxiliary electrode in order to improve the operation voltage margin. Reciprocal sustain pulse waveforms and modified auxiliary pulse waveforms were applied to the sustain and auxiliary electrode, respectively. During the sustain period, the influence of the address electrode on the luminous efficacy of long-coplanar gap discharges was mitigated by application of reciprocal sustain pulse waveforms. Modified auxiliary pulse waveforms maintained the high efficacy obtained from the AC PDP with an auxiliary electrode. The proposed reciprocal sustain and modified auxiliary pulses waveforms can induce stable discharges in long-coplanar gap discharges and can control wall charges with a wider auxiliary pulse voltage margin, thereby enhancing the luminous efficacy of the AC PDP with an auxiliary electrode.

  • PDF

폐플라스틱을 재활용한 폴리머 콘크리트 특성 (The Properties of Polymer Concrete Recycling Plastic Waste)

  • 조병완;문린곤;박승국;임상헌
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.441-444
    • /
    • 2003
  • Polymer concrete has more useful than cement concrete in the strength and durability. So, it is widely utilizing as panel for wall, manhole for communication, foundation and underground connection box, etc. But polymer concrete is a defect that is disadvantageous in economical aspect because cost of resin is expensive. Polymer concrete (PC) using unsaturated polyester resins based on recycled polyethylene terephthalate(PET) plastic waste were used in our study for grasping its mechanical properties such as compressive strength, tensile strength, flexural strength and chemical resistance was tested by dealing with 20% HCl, 30% NaOH. As a result of it, compressive, tensile and flexural strength of PC indicated 752kgf/$\textrm{cm}^2$, 80kgf/$\textrm{cm}^2$ and 243kgf/$\textrm{cm}^2$ kind of satisfaction successively. Also, properties of chemical resistance are superior to those of cement concrete.

  • PDF

-10℃ 조건에서의 보온양생방법 변화에 따른 벽체 콘크리트의 온도이력 (Temperature History of the Wall Concrete Subjected to -10℃ depending on Heat Curing Method)

  • 한상윤;손호정;정상현;안상구;한천구;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.255-256
    • /
    • 2011
  • This study investigates the effect of a curing condition on the temperature history and strength development of concrete under -10℃. Combination of various curing methods was applied, i.e. a conventional form was combined with compressed insulation, heat panel and heat cable. Results showed that the concrete cured by a single use of a conventional form resulted in serious deterioration of early strength development. However, other concretes cured by the proposed curing methods maintained the temperature of the concretes between 5 and 20℃, and thus resulted in no frost damage.

  • PDF

대면적의 LCD를 위한 갇혀진 Locked Super Homeotropic (LSH) 액정 디바이스 (Locked Super Homeotropic (LSH) liquid crystal device for large size LCD)

  • 박상현;송일섭;김완철;오세태;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.146-149
    • /
    • 2004
  • We have studied a liquid crystal (LC) mode (named locked super homeotropic (LSH)) in which the LCs aligned homeotropically are locked by surrounding walls such as cubic, hexagonal and cylinder. In the device, the vertically aligned LCs tilt down symmetrically around the center of the cell when a voltage is applied and thus it exhibits wide viewing angle. The structure of this LSH mode is suitable for large-sized display panels. since the LCs are locked in micro domains the LCs do not flow to the bottom of the panel by gravity. This mode is applicable to achieve high performance TFT-LCD TV because of high performance characteristics such as high contrast, high brightness, wide-viewing angle.

  • PDF

"You can't help but Like it": An Investigation of Mandatory Endorsement Solicitation and Gating Practices in Online Social Networks

  • Church, E. Mitchell;Passarello, Samantha
    • Asia pacific journal of information systems
    • /
    • 제26권1호
    • /
    • pp.124-142
    • /
    • 2016
  • Companies operating in social network platforms continue to improve and expand their marketing techniques. This study examines the practice of "gating", which involves virtual barriers between social network users and company content. Gates demand mandatory user endorsements, in the form of a Facebook "Likes", Twitter "retweets" etc., to gain access to company content, such as coupons and rewards,. Gating practices demand a mandatory endorsement before any content consumption takes place. Thus, while user endorsements are assumed to arise voluntarily from trusted known sources, gating practices would appear to violate this assumption. However, whether this violation lessens the effectiveness of gating practices still requires empirical validation. We investigate this question through the use of a unique panel data set that includes data on "like" endorsements obtained from a number of real-world Facebook business pages. Results of the study show that gating practices are effective for endorsement solicitation; however, gates may interfere with more traditional marketing activities.

뜬바닥 구조를 이용한 격실의 소음 및 진동저감 (Reduction of noise and vibration of cabin by using the floating floor)

  • 김현실;김봉기;차선일;김영수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.300-303
    • /
    • 2004
  • In this paper, floor impact noise reduction in a cruise ship cabin by using floating floor is studied. A mock-up is built by using 61 steel plate, and two identical cabins are made where 25t panel is used to construct wall and ceiling inside the steel structure. Various floating floor systems are tested for which normalized impact noise is measured according to ISO 140-7 It is shown that effect of VL(Visco-elastic Layer) is negligible when it is used between deck and mineral wool, since most vibration absorption occurs in the wool. In addition, direction of the mineral wool fiber affects impact noise significantly.

  • PDF

공동주택에서 완충재를 이용한 바닥충격음 저감 System 연구 (Investigating of a Floor-Impact Isolation System Using Damping Materials In Apartment Buildings)

  • 송희수;정영;정정호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.499-504
    • /
    • 2004
  • The purpose of this study is to investigate a investigating of a floor-impact isolation system using damping materials in apartment buildings. The stiffness elastic modulus(k) by puls impact forces were calculated loss factor by Hilbert transforms. It is absolved that natural frequency was moved floor shock-absorbing materials and the impact force was reduced by floor panel. The slab was constructed by damping materials. As towards a result, the system showed inverse A 45dB by heavy weight-impact noise and inverse A 52dB by light-impact noise. High frequencies impact-noise can be reduced by upgrading naturial frequency of vibration and noise in the system.

  • PDF

고부가가치선의 Unit Cabin Mock-up 을 이용한 캐빈소음 저감 연구 (Cabin Noise Reduction using Unit Cabin Mock-up of High Value Ship)

  • 주원호;송근복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.483-484
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value ship such as drill ship and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission, and radiated noise measurements were carried out by using the mock-up of living quarter. From the tests, it was found out that the combined noise level of a unit cabin could be dominated by the radiated noise from wall panel in low frequency range and the design guidelines for the noise control of unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

  • PDF