Correlation of the Wall Skin-Friction and Streamwise Velocity Fluctuations in a Turbulent Boundary Layer(I) -Analysis of Long-Time Averaged Space-Time Correlation- (난류경계층에서 벽마찰력과 유동방향 속도성분과의 상관관계(I)-시간 평균된 공간-시간 상관관계의 분석-)

  • Yang, Jun-Mo;Yu, Jeong-Yeol;Choe, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.1
    • /
    • pp.140-152
    • /
    • 1997
  • A simultaneous measurement of the wall skin friction and near-wall streamwise velocity fluctuations is performed using hot film and hot wire anemometers to investigate the relation between them. Near-wall turbulence statistics measured with a hot-wire probe are in good agreement with previous results. Turbulence properties of the wall skin friction fluctuations measured with a hot film also show fairly good agreements with those measured by others except that rms level is lower in the present study. Long-time averaged space- time correlations show that the wall skin friction is highly correlated with a turbulence structure which is tilted from the wall in the streamwise direction. Tilting angles are obtained from the phase shifts between the wall skin-friction and streamwise velocity fluctuations. The convection velocity of the near-wall streamwise velocity obtained from the space-time correlation is in good agreement with that from the direct numerical simulation database.

Correlation of the Wall Skin-Friction and Streamwise Velocity Fluctuations in a Turbulent Boundary Layer(II) (난류경계층에서 벽마찰력과 유동방향 속도성분과의 상관관계(II))

  • Yang, Jun-Mo;Yu, Jeong-Yeol;Choe, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.3
    • /
    • pp.427-435
    • /
    • 1997
  • Conditional sampling techniques are utilized to investigate the relation between the wall skin-friction and stream wise velocity fluctuations in a turbulent boundary layer. Conditionally averaged results using a peak detection and the VITA (variable-interval time-averaging) technique show that a high skin friction is associated with high frequency components of the wall skin-friction fluctuations. The conditionally averaged wall skin-friction fluctuations obtained by using the VITA technique have a positively-skewed characteristics compared with the conditionally averaged stream wise velocity fluctuations. It is confirmed that there exists a phase shift between the wall skin-friction and stream wise velocity fluctuations, which was also found from the long-time averaged space-time correlations. The amount of phase shift between the wall skin-friction and stream wise velocity fluctuations is the same as that from the long-time averaged space-time correlations and does not change despite the variation of the detection threshold.

Control Performance of Friction Dampers Using Flexural Behavior of RC Shear Wall System (전단벽식 구조의 휨거동을 이용한 마찰감쇠기의 제어성능)

  • Chung, Hee-San;Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won;Byeon, Ji-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.856-863
    • /
    • 2008
  • High-rise apartments of shear wall system are governed by flexural behavior like a cantilever beam. Installation of the damper-brace system in a structure governed by flexural behavior is not suitable. Because of relatively high lateral stiffness of the shear wall, a load is not concentrate on the brace and the brace cannot perform a role as a damping device. In this paper, a friction damper applying flexibility of shear wall is proposed in order to reduce the deformation of a structure. To evaluate performance of the proposed friction damper, nonlinear time history analysis is executed by SeismoStruct analysis program and MVLEM(multi vertical linear element model) be used for simulating flexural behavior of the shear wall. It is found that control performance of the proposed friction damper is superior to one of a coupled wall with rigid beam. In conclusion, this study verified that the optimal control performance of the proposed friction damper is equal to 45 % of the maximum shear force inducing in middle-floor beam with rigid beam.

Configurations of the Friction Dampers Installed in a Reinforced Concrete Shear Wall-Moment Frame System (철근콘크리트 전단벽-모멘트골조 형식 건물에 대한 마찰형 감쇠기 설치방식 비교연구)

  • Park, Ji-Hun;Kim, Gil-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.53-67
    • /
    • 2008
  • In this study, seismic control performance of friction dampers installed in a reinforced concrete shear wall-moment frame system, of which main lateral force resisting system is a shear wall, is investigated. Three configurations of friction dampers are investigated. One is a diagonal brace type reinforcing the shear wall directly, another is a diagonal brace type reinforcing the moment frame without the shear wall, and the other one is a vertical boundary element type installed at both ends of the shear wall. In addition, various levels of the total friction force and its distribution methods are examined. Time history analysis considering material nonlinearity is conducted for seismic loads increased by the enhanced design code compared to the initial design loads, and energy dissipation, lateral loads and structural member damages are analyzed. As a result, the shear wall-reinforcing diagonal brace type with the total friction force of 30 % of the reference friction force gives the best performance on the whole, and the distribution methods of the friction force do not have remarkable difference in effects. Also, concentrated installation in adjacent four stories shows just a little compromised control performance compared to the entire story installation.

The estimation of the wall friction coefficient in tunnels by in-situ measurement (현장측정을 통한 터널 내 벽면마찰계수 추정 연구)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Lee, Ho-Hyung;Baek, Doo-San;Na, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.405-421
    • /
    • 2018
  • In most of cases, the wall friction coefficients applied for local tunnel design are quoted directly from foreign data or local design guideline. In the previous studies, the wall friction coefficient was estimated using the velocity decay method. However, it is difficult to estimate the wall friction coefficient when the convergence wind velocity in the tunnel is negative (-) or if there is a change in the natural wind. Therefore, in this study, the wall friction coefficient is estimated by applying the dynamic simulation technique in addition to the conventional the velocity decay method. As a result of the analysis, the coefficient of wall friction in the tunnels for the total of 9 tunnels (18 tubes both directions) was 0.011~0.025, and the mean value was estimated to be 0.020. In addition, the wall friction coefficient obtained quantitatively through this study was compared with the current design criteria.

Rotordynamic Analysis of a Labyrinth Seal Using the Moody's Friction-Factor Model (Moody 마찰계수식을 사용한 래버린스 실의 회전체 동역학적 해석)

  • Ha, Tae Woong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.52-58
    • /
    • 1999
  • The leakage and rotordynamic coefficients of see-through type gas labyrinth seals are determined using a two-control-volume-model analysis with Moody's wall-friction-factor formula which is defined with a large range of Reynolds number and relative roughness. Jet flow theory are used for the calculation of the recirculation velocity in the cavity. For the reaction force from the labyrinth seal, linearized zeroth-order and the first-order perturbation equations are developed for small motion about a centered position. The leakage and rotordynamic coefficient results of the present analysis are compared with Scharrer's theoretical analysis using Blasius' wall-friction-factor formula and Pelletti's experimental results. The comparison shows that the present analysis using Moody's wall-friction-factor formula and Scharrer's theoretical analysis using Blasius' wall-friction-factor formula give the same results for a smooth seal surface and the range of Reynolds number less than $10^5$.

  • PDF

The Effect of Wall Friction on Deformation Characteristics of the Cellular Bulkhead (Cell 구조물의 변형특성에 미치는 셀 벽면 마찰의 영향)

  • Son, Dae-San;Jang, Jeong-Wook;Kim, Kyong-Yeol;Kim, Hyun-Guk;Chung, Youn-In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.4
    • /
    • pp.230-234
    • /
    • 2010
  • This study examined the effect of wall friction on deformation characteristics of the cellular bulkhead, in terms of artificial wall friction based on the results of model tests according to the existing penetration ratio and loading height. 1. The effect of wall friction on deformation characteristics of the cellular bulkhead turned out to be less as the loading height decreases and the penetration ratio increases. The yield load also becomes less as wall friction decreases. 2. The ratio of the rotational displacement to the horizontal displacement of the cellular bulkhead becomes less as the loading height decreases and the penetration ratio increases. Hence it is concluded that the effect of wall friction has close relationship with the rotational displacement.

A Modfication Study on Horizontal Earth Pressure in the Symmetrically Sloped Backfilled Space (대칭적으로 경사진 되메움된 공간에서의 수평토압에 대한 수정연구)

  • Moon, Chang-Yeul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.2
    • /
    • pp.57-64
    • /
    • 2003
  • Marston (1913) and Spangler's (1982) theory was widely used in the analysis of the earth pressure of the narrow and long excavated ditch type backfield ground. Their theory was more clearly explained by expressing the minor principle stress arch connecting the minor principle stress link induced by interaction between the excavated wall surface and the backfilled earth. which was done by R.L. Handy(1985). Later C.G. Kellogg(1993) extended the study from vertical symmetric to incline symmetric in the backfill space type research. In the C.G. Kellogg's study, it is assumed that the resistance of wall friction on the sloping wall could be replaced by the internal friction angle in the sloping section bottom. In the study, the resistance of wall friction in the sloping section bottom, which was applied by C.G. Kellogg, would be different in magnitude with the resistance of wall friction in sloping section. The magnitude is expected to affect in the earth pressure calculation and verified by the soil test box, the C.G. Kellogg's theory, the numerical analysis and the modified C.G. Kellogg's theory considering the friction resistance to influence the incline wall.

  • PDF

Experimental study on hybrid FRP-steel RC shear wall with replaceable dampers

  • Shiying Xiao;Mengfu Wang
    • Steel and Composite Structures
    • /
    • v.52 no.2
    • /
    • pp.217-236
    • /
    • 2024
  • The objective of this paper was to discuss the seismic performance of hybrid FRP-steel reinforced concrete shear wall with replaceable friction dampers at the feet of the wall. The hysteretic characteristics of five wall specimens were studied by pseudo-static loading tests. The results showed that the damage of the specimens was concentrated on the friction dampers, and the energy consumption capacity was increased while making up for the defect of low ductility of FRP reinforced wall specimens. And the repairability of the wall after earthquake was improved. Finally, a calculation method of initial stiffness of shear wall with replaceable dampers was proposed.

Partition method of wall friction and interfacial drag force model for horizontal two-phase flows

  • Hibiki, Takashi;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1495-1507
    • /
    • 2022
  • The improvement of thermal-hydraulic analysis techniques is essential to ensure the safety and reliability of nuclear power plants. The one-dimensional two-fluid model has been adopted in state-of-the-art thermal-hydraulic system codes. Current constitutive equations used in the system codes reach a mature level. Some exceptions are the partition method of wall friction in the momentum equation of the two-fluid model and the interfacial drag force model for a horizontal two-phase flow. This study is focused on deriving the partition method of wall friction in the momentum equation of the two-fluid model and modeling the interfacial drag force model for a horizontal bubbly flow. The one-dimensional momentum equation in the two-fluid model is derived from the local momentum equation. The derived one-dimensional momentum equation demonstrates that total wall friction should be apportioned to gas and liquid phases based on the phasic volume fraction, which is the same as that used in the SPACE code. The constitutive equations for the interfacial drag force are also identified. Based on the assessments, the Rassame-Hibiki correlation, Hibiki-Ishii correlation, Ishii-Zuber correlation, and Rassame-Hibiki correlation are recommended for computing the distribution parameter, interfacial area concentration, drag coefficient, and relative velocity covariance of a horizontal bubbly flow, respectively.