• Title/Summary/Keyword: Wall Fire

Search Result 356, Processing Time 0.024 seconds

A Study on Concurrent Fire Appearance through Openings (개구부를 통한 동시다발적인 화재성상에 관한 연구)

  • Min, Se-Hong;Lee, Jae-Moon
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.90-96
    • /
    • 2012
  • Since vertical flame spread speed on exterior materials is much faster than horizontal fire, analysis of its fire characteristic is required. For the study of vertical fire pattern created by penetrating windows or openings from the exterior wall of buildings, the research is based on the fire simulation for an aluminum-complex-panel with which is commonly used as exterior materials and consists of polyethylene core material. As a result, the flame reaches the 2nd floor after 135 seconds in the early stage of fire, the 10the floor after 470 seconds and the 30th floor, the highest floor, after 711 seconds. The result shows that fire spread abruptly expands on upper floor due to stack effect of a turbulent flow or exterior materials. In consequence, we can confirm a serious problem that a conflagration of a building through an opening that is equipped with the exterior-materials spreads into interior of building at that same time.

Development of a Single Fire Alarm System of House Based on Wireless Communication (무선 감응식 주택 단독 화재 경보 시스템 개발)

  • Park, Hyeon-Ho;Cho, Seong-Jin;Park, Byeong-Hwa;Heo, Jeong-Hun;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1017-1022
    • /
    • 2018
  • In this paper, a single house fire alarm device, which can solve the problem of fire perception at midnight time and the attenuation of alarm signal due to the wall between rooms based on the wireless communication, was developed. The radio controlled fire alarm device was designed to allow fire to be recognized quickly and accurately by monitoring the temperature and $CO_2$ concentration based on the temperature sensor and gas sensor, by detecting the fire in the house and by transmitting the fire alarm to the individual wireless alarms of other rooms using the wireless transmission/reception module. Using the Arduino as a main control device, three independent fire alarm device prototypes were made, and their usefulness was verified by the correct operations in temperature and gas tests.

A Study on Fire Dynamics Simulation on the Arrangement of Aero System in the Residential (주거공간 에어로 시스템 배치에 관한 화재시뮬레이션 연구)

  • Choi, Doo Chan;Ko, Min Hyeok;Lee, Doo Hee;Park, Kye Won;Choi, Jeong Min;Lee, Yong Kwon;Kim, Gil Nam;Sun, Kyoung Soo
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.890-896
    • /
    • 2021
  • Purpose: The called Aero System is important to find the well detected place in the livingroom or bedroom so, it needs to the confirmation through the Fire Dynamics Simulation Method: A fire simulation of a residential space of 59 m2 was performed, and in order to find the point where the fire environment was exposed quickly, measuring points were installed at 0.6 m and 1.5 m in height for each bedroom and living room, and the point where the fire was quickly detected was confirmed. Result: It was confirmed that the temperature and carbon monoxide sensor set at a point of 1.5 m was quickly detected at the reference value. Conclusion: The Fire detection would be relatively quick if the product in which the fire extinguishing module and the AQI module were separated was installed on the wall.

Fire Resistance Performance and Thermal Performance Evaluation of Structural Insulated Panels for Low-Energy Houses (구조단열패널의 저에너지주택 적용을 위한 내화 및 단열성능 평가)

  • Lee, Hyeon-Ju;Nah, Hwan-Seon;Lee, Cheol-Hee;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.3 no.2
    • /
    • pp.36-46
    • /
    • 2012
  • Structure Insulated Panel (SIP) is an wooden structure material with which structure and insulation functions are satisfied. Hence, it would be a cost-effective model to implement low energy house which has higher insulation and structure performance and which the wall thickness is able to be reduced. In this study, performance of thermal insulation and fire resistance were evaluated in order to verify applicability to low energy house. Fire resistance test is performed on vertical load bearing members for partitions, and the test results satisfy one hour of fire resistance condition according to KS F 2257. The members include two layers of fireproof gypsum board with thicknesses of 12.5mm attached to SIP. Thermal insulation performance is satisfied with the 2012 standard ($0.225W/m^2{\cdot}K$). As the performance of resistance and thermal insulation are satisfied, SIP is expected to be applied to low energy building materials. In the future, the structural safety will be confirmed by structural performance and seismic performance test and the guidelines for distribution will be drawn up.

An Experimental Study on the Effect of the Balcony on the Vertical Smoke Movement of the High Rise Building (고층건물의 수직방향 연기거동에 미치는 발코니의 영향에 관한 실험적 연구)

  • Yang Seung-Shin;Kim Sung-Chan;Ryou Hong-Sun;Shim Sang-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.42-48
    • /
    • 2005
  • The present study investigates the effect of balcony on external smoke movement of high rise building through the fire tests of the 1/10 reduced model scale using Froude scaling. A hexane pool fire is used to examine the smoke movement for various opening sizes of balcony and temperature distributions are measured by T-type thermocouples. Also, hydrogen bubble technique is applied to visualize the smoke movement near the balcony. Measured temperatures of the closed balcony is 2.5 times higher than those of the open balcony because the external smoke in case of the closed balcony rise along the vertical wall. The maximum vertical temperature of partially closed balcony is similar with fully closed balcony and mean temperature inside of balcony increases as opening size of balcony decreases. The experimental results show that the balcony space plays an important roles in preventing fire propagation and cooling of smoke layer. In order to ensure the fire safety in high rise building design, a series of systematic researches are required to examine the various type of balconies.

Study on the Fire Suppression by Heat Transfer of Thermal Insulation Materials (건축물 외단열재의 열전달평가를 통한 화재 억제 방안 연구)

  • Ryu, Hwa Sung;Shin, Sang Hun;Song, sung young;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.277-278
    • /
    • 2018
  • Improvement of insulation performance of buildings is a major part. Adiabatic method The adiabatic method minimizes the heat loss of the building. External insulation uses insulation to prevent fire. Ambient air hazards are less prone to fire. When a fire occurs, a phenolic pattern is formed and bond strength with the wall increases. EPS insulation and phenol foam were used to compare external heat transfer and external heat transfer. The heat transfer properties of phenolic foam and styrofoam were evaluated as follows. In the mortar and styrofoam structure, the problem of styrofoam reaching the burning point occurred before the collapse of the mortar, and the phenol foam had a problem in that when the direct fire was continued on the phenol foam. The characteristics of continuous infiltration appeared. In the case of mortar and phenol foam + styrofoam, the heat penetrated into the interior due to the shrinkage due to the shrinkage of the carbon screen on the phenol foam. However, when reinforced with glass mesh on the outer surface, And to reduce infiltration.

  • PDF

Numerical Study on the Effect of Damper Position on Characteristics of Thermal Flow at the Vestibules and Fire Door (댐퍼의 위치가 부속실 및 방화문에서의 열 유동 특성에 미치는 영향에 관한 수치해석 연구)

  • Moon, Hyo-Jun;Ko, Gwon-Hyun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The pressurized smoke control system is important for fire safety in building because it is directly concerned with egress time of people. Even though the damper plays an essential role in the pressurized smoke control system, the phenomena of backflow smoke occurs for a certain the damper position. The research for a position of damper effects on distribution of air flow at the fire door is not performed. In this study, numerical simulation using FDS 5.5 was carried out to analyze the effect of the position of damper on flow distribution at the fire door. To simulate real situation, effects of opening and closing of fire door was considered. As a result, when HRR was between 200 kW and 400 kW, in the case which the damper was on the opposite wall of the fire door, the back flow to the vestibules was large compared to the two other cases of damper position. But when HRR was above 400 kW, Effect on damper position was not occurred.

A Study on the Fire Spread between Office Room and Atrium in the Atrium Building (아트륨 빌딩에서의 사무실과 아트륨간의 화재확산에 관한 연구)

  • Lee, Su-Kyung;Kim, Jong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.78-83
    • /
    • 2000
  • Generally, There is to install fire resist shutter or to compart between the office room and the atrium in the atrium buildings in Korea. But, Glass wall that is installed sprinkler which purpose to protect it from fire, is already installed between the office room and the atrium in the advanced nations. We study this problem as follow; We made the fire scenario, and analyze each scenario using FASTLite is fire modeling software and BREAK1 is to predict the window breakage time in the compartment fire. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

The Study on Real Scale Fire Test of Building Exterior Wall Assemblies (건축물 외장재 수직확산 실대형 화재실험에 관한 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.295-300
    • /
    • 2011
  • 국내 건축물 외장재의 화재위험성 판단을 위한 기준 설정 및 건축물 외장재 수직확산 방지를 위하여 국내 외 실규모 화재실험을 비교 분석하였다. 현재 미국, 영국 등의 화재안전선진국들에서는 NFPA 285, BS 8414-1 등의 실대형 화재 실험을 통하여 외장재의 화재위험성을 판단하고 있다. 이에 본 연구에서는 국내 외 건축물 외장재의 수직화재확산 성능 평가 방법들의 비교 분석을 통하여 국내 실정에 맞는 실대형의 화재실험 방법을 결정하고자 하였다. 본 결과를 통해 건축물의 단위 공간에서 화재가 발생하여 화재의 성장이 플래시오버에 도달한 후 창문 등의 개구부를 통하여 화염이 출화되었을 때 이러한 화염에 의한 건축물 외장재의 수직화재 확산 성능 평가하는 건축물 외장재 수직확산 실대형 화재실험 장비를 개발하고자 하였다.

  • PDF

A Study on the Change of Surface Temperature of Back Panel by Variation of the Air-Space Distances on the Inside of Curtain Wall (커튼월 내부 공기층의 BACK PANEL 표면온도에 관한 연구)

  • Lee, Duck-Hyung;Son, Won-Tug;Choi, Hyun-Sang;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.3
    • /
    • pp.87-93
    • /
    • 2011
  • When applying back panel(this material is aluminum complex panel coated with fire resistance substances) for curtain wall, solar radiation and heat storage of indoor air occurs to result in thermal warpage for back panel. The purpose of this analysis is to find out the cause of thermal warpage and come up with a solution to prevent changes of back panel and reduce elements that bring negative visual elements. Also to solve this problem analyse that case to reduce heat transfer by inserting additional material and cases to increase air space distance.