• Title/Summary/Keyword: Wafer Position

Search Result 79, Processing Time 0.026 seconds

Study on Auto Focusing System of Laser Beam by Using Fiber Confocal Method (파이버 공초점법을 이용한 레이저 빔 자동 초점 제어 장치에 관한 연구)

  • Moon, Seong-Wook;Kim, Jong-Bae;King, Sun-Hum;Bae, Han-Seong;Nam, Gi-Jung
    • Laser Solutions
    • /
    • v.9 no.3
    • /
    • pp.7-13
    • /
    • 2006
  • Auto focusing system to find optimized focal position of laser beam used for material process has been investigated by using fiber confocal method. Wavelength of laser diode (LD) and diameter of single-mode fiber are 780nm and $5.3{\mu}m$, respectively. Intensity distributions of beam reflected from the surface of mirror and silicon bare wafer have been observed in a gaussian form. Experimental results show that focal position obtained by LD is shifted from one observed from surface scribed by laser about $80{\mu}m$. It is due to the difference of wavelength and each divergence of between LD and laser used for material process. It is confirmed that auto focusing control system through position calibration has operated steadily.

  • PDF

Study on auto focusing system of laser beam by using fiber confocal method (파이버 공초점법을 이용한 레이저 빔 자동 초점 제어 장치에 관한 연구)

  • Moon, Seong-Wook;King, Sun-Hum;Kim, Jong-Bae;Bae, Han-Seong;Nam, Gi-Jung
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • Auto focusing system to find optimized focal position of laser beam used for material process has been investigated by using fiber confocal method. Wavelength of laser diode (LD) and diameter of single-mode fiber we 780nm and $5.3{\mu}m$, respectively. Intensity distributions of beam reflected from the surface of mirror and silicon bare wafer have been observed in a gaussian form. Experimental results show that focal position obtained by LD is shifted from one observed from surface scribed by laser about $80{\mu}m$. It is due to the difference of wavelength and each divergence of between LD and laser used for material process. It is confirmed that auto focusing control system through position calibration has operated steadily.

  • PDF

65nm급 300mm Wafer 세정조 개발을 위한 유동 특성연구

  • Kim, Jin-Tae;Kim, Gwang-Seon;Lee, Seung-Hui;Jeong, Eun-Mi
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.174-178
    • /
    • 2007
  • The cleaning process to remove small particles, ions, and other polluted sources is one of the major parts in the recent semiconductor industry because it can cause fatal errors on the quality of the final products. According to the other reports, the major factors of bath's fluid motion are the cleaning method, nozzle, the geometry (of bath, guide and wafer), and the position (of guide and wafer). So to enhance cleaning efficiency in the bath, these factors must be controlled. The purpose of this study is to analyze and visualize fluid motion in the cleaning bath as basic data for designing the nozzle system and finding the process control parameters. For that, we used the general CFD code FLUENT.

  • PDF

A study on the automatic wafer alignment in semiconductor dicing (반도체 절단 공정의 웨이퍼 자동 정렬에 관한 연구)

  • 김형태;송창섭;양해정
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.105-114
    • /
    • 2003
  • In this study, a dicing machine with vision system was built and an algorithm for automatic alignment was developed for dual camera system. The system had a macro and a micro inspection tool. The algorithm was formulated from geometric relations. When a wafer was put on the cutting stage within certain range, it was inspected by vision system and compared with a standard pattern. The difference between the patterns was analyzed and evaluated. Then, the stage was moved by x, y, $\theta$ axes to compensate these differences. The amount of compensation was calculated from the result of the vision inspection through the automatic alignment algorithm. The stage was moved to the compensated position and was inspected by vision for checking its result again. Accuracy and validity of the algorithm was discussed from these data.

A Study on the Development of Wafer Notch Aligner (노치형 웨이퍼 정렬기 개발에 관한 연구)

  • Na, Won-Shik
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.412-418
    • /
    • 2009
  • This study aims to develop a system that enables 20 to 25 wafers to be automatically aligned at the position of the corresponding serial number and facilitates the checkout of wafer processing by sensing them before and after semiconductor processing. It also suggests compensation algorithm and stepper motor control algorithm that carefully align notches. This study minimizes the rate of occurrence by adopting materials of which the surface has proper coefficient of friction when wafers are rotating and that do not rarely produce particles. This study completed the development of a slip resistance apparatus and carried out performance tests through mathematical verification. This system is expected to improve semiconductor yield due to anti-pollution technology in semiconductor processing and can be selectively applied to a large size wafer over 450mm in the future.

  • PDF

Osteotomy and iliac bone graft for the treatment of malunion caused by failed mandibular fracture reduction

  • Hwang, Kun;Ma, Sung Hwan
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.6
    • /
    • pp.384-386
    • /
    • 2020
  • This report describes osteotomy and iliac bone graft for malunion caused by failed mandibular fracture reduction. A 27-year-old man was referred 3 months after a motor vehicle accident. At another hospital, two operations had been performed for symphyseal fracture using two resorbable plates. Malocclusion was noted, and panoramic radiography and computed tomography revealed a misaligned dental arch, with a 9.37-mm gap between the central and the lateral incisor of the left mandible. A wafer was made from the patient's dental model, and a maxillary arch bar was applied. Through a lower gingivolabial incision, osteotomy was performed between the malunited symphyseal fracture segments. Both segments were reduced to their original position using the wafer and fixed with titanium miniplates via intermaxillary fixation (IMF). The intersegmental gap was filled with cancellous bone from the iliac crest. The gingival defect was covered with a mucosal transposition flap from the gingivolabial sulcus. IMF and the wafer were maintained for 5 and 9 weeks, respectively. At postoperative week 13, the screws were removed from the mandible and satisfactory occlusion was noted. His mouth opening improved from 2.5 to 3 finger breadths (40 mm). This case demonstrates the need for sufficient IMF when using resorbable plates.

Development of Chemical Mechanical Polishing machine by Conical Drum (원뿔형 드럼을 이용한 화학기계적 연마기의 개발)

  • 서헌덕
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.525-529
    • /
    • 1999
  • A cone shape drum polisher was developed to make up for the demerits of conventional CMP apparatus. The developed equipment has several superiorities. First of all, it can achieve uniform velocity profile on all the contact line because of its shape and easy to control the amount of slurry at the position of use. The whole area of wafer surface is exposed to the visual area except the contact line between wafer and drum, hence we can detect polishing end point more easily than any other polishing equipments. Also it has additional merits such as small foot print and polishing load. Polishing characteristics were investigated by developed equipment.

  • PDF

MEMS for Heterogeneous Integration of Devices and Functionality

  • Fujita, Hiroyuki
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.3
    • /
    • pp.133-139
    • /
    • 2007
  • Future MEMS systems will be composed of larger varieties of devices with very different functionality such as electronics, mechanics, optics and bio-chemistry. Integration technology of heterogeneous devices must be developed. This article first deals with the current development trend of new fabrication technologies; those include self-assembling of parts over a large area, wafer-scale encapsulation by wafer-bonding, nano imprinting, and roll-to-roll printing. In the latter half of the article, the concept towards the heterogeneous integration of devices and functionality into micro/nano systems is described. The key idea is to combine the conventional top-down technologies and the novel bottom-up technologies for building nano systems. A simple example is the carbon nano tube interconnection that is grown in the via-hole of a VLSI chip. In the laboratory level, the position-specific self-assembly of nano parts on a DNA template was demonstrated through hybridization of probe DNA segments attached to the parts. Also, bio molecular motors were incorporated in a micro fluidic system and utilized as a nano actuator for transporting objects in the channel.

Average Flow Model with Elastic Deformation for CMP (화학적 기계 연마를 위한 탄성변형을 고려한 평균유동모델)

  • 김태완;구영필;조용주
    • Tribology and Lubricants
    • /
    • v.20 no.5
    • /
    • pp.284-291
    • /
    • 2004
  • We present a three-dimensional average flow model considering elastic deformation of pad asperities for chemical mechanical planarization. To consider the contact deformation of pad asperities in the calculation of the flow factor, three-dimensional contact analysis of a semi-infinite solid based on the use of influence functions is conducted from computer generated three dimensional roughness data. The average Reynolds equation and the boundary condition of both force and momentum balance are used to investigate the effect of pad roughness and external pressure conditions on film thickness and wafer position angle.

Wafer Position Recognition Based on Generalized Symmetry Transform (일반화 대칭 변환 기반의 웨이퍼 위치 인식)

  • Jun, Mi-Jin;Kang, Su-Myung;Lee, Joon-Jae
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.38-39
    • /
    • 2012
  • 본 논문에서는 반도체 생산 공정 중 클리닝 공정 과정에서 웨이퍼가 정확한 위치에 장착되었는지를 판단하기 위하여 투영 변환을 이용하여 원형 모양 웨이퍼로 복원하고 에지를 추출한 후 일반화 대칭 변환(Generalized Symmetry Transform, GST) 방법을 적용하여 웨이퍼의 윤곽을 검출하여 위치를 검사하는 방법을 제안한다.

  • PDF