• Title/Summary/Keyword: WRIST

Search Result 1,161, Processing Time 0.036 seconds

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

Development and Characterization of Wearable Film-heaters Used in Thermotherapy for Senior Citizens (노인의 온열치료를 위한 웨어러블 면상발열체의 개발 및 특성 파악)

  • Yang, Kyungwhan;Cho, Kyoungah;Choi, June-Seek;Im, Kiju;Kim, Sangsig
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.412-415
    • /
    • 2016
  • In this study, we fabricated the wearable film-heaters used in thermotherapy for senior citizens and investigated the heat generation characteristics. The wearable film-heaters embedded into eco-flex were constructed with indium tin oxide (ITO) nanoparticles coated on glass fibers. Under a stretching strain of 30%, the wearable film-heaters stably operated with temperature variation of 10%. In addition, the wearable film-heater worn on the wrist increased the temperature of the wrist from $35^{\circ}C$ to $43^{\circ}C$ within 2 min.

Musculoskeletal Pain Levels among Hairdressers and Affecting Factors (헤어드레서의 근골격계 통증수준과 관련 요인)

  • Joung, Nyun Koo;Jung, Jong-Hyeon;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.2
    • /
    • pp.130-137
    • /
    • 2017
  • Objectives: This study was designed to define the musculoskeletal pain levels among selected hairdressers and the risk factors for these musculoskeletal pain levels. Methods: A survey was conducted from July 1 to August 10, 2011 among 199 hair dressers working in Seoul and Gyeonggi-do Province using a self-administered Nordic Musculoskeletal Questionnaire. The affecting factors for musculoskeletal pain levels were analyzed using multiple logistic regression. Results: The musculoskeletal pain levels by body region were low back(6.19), ankle/foot(6.14), shoulder(5.27), knee(5.27), back(5.23) and wrist/hand(5.18). In stepwise regression, significant actors affecting the level of pain by body region were height on wrist/hand, low back, and knee and age on elbow. Conclusions: Based on these results, in order to prevent musculoskeletal diseases among hair dressers, standing time should be decreased and stretching should be performed regularly to protect the low back and knee.

The Study of Distribution of Upper Extremity Surgery for Korean Baseball Player (한국 프로야구 선수의 상지 수술 분포 연구)

  • Park, Jun-hyuck;Seo, Hyun-kyu
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2016
  • Background: The objective of this research is to provide base line data on Korea Baseball rehabilitation treatment by presenting the distribution of upper extremity surgeries according the surgical sites of Korean professional baseball players. Methods: The targets of this research are 561 players from nine Korean baseball clubs. The number of players that have undergone surgery was investigated. In other words, the frequency of shoulder joint surgeries, elbow joint surgeries, and wrist and hand surgeries per each baseball club was investigated. Results: The number of the players who have had surgeries was 151, but among the players, there were some who have had repeated surgeries for which the total number of surgery experience was 162. The result showed that elbow joint surgeries were the most frequently enacted, followed by shoulder joint surgeries, and wrist and hand surgeries. From the nine clubs, Samsung was the club with the highest frequency of surgeries. Conclusions: This research shows that Korean professional baseball players need special training centers with systematic rehabilitation programs. Another conclusion suggests that urgent need for rehabilitation program of upper arm which particularly focused on elbow joint is existing. On the basis of this research, we expect more studies on the specific rehabilitation programs which is categorized by injury areas.

  • PDF

Reliability of Scapular Winging Measurement Using a Scapulometer (익상견갑의 평가를 위한 "Scapulometer"의 신뢰도 연구)

  • Weon, Jong-Hyuek;Choi, Houng-Sik;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2010
  • This study was undertaken to develop the scapulometer, a measuring tool for scapular winging, and to determine the reliability of scapulometer. Thirty subjects with scapular winging greater than 2 cm participated in this study. Two examiners measured scapular winging using the scapulometer. Standardized measurement position of each subject was as follows: neutral position of shoulder and wrist, $90^{\circ}$ flexion of elbow, and cuff weight of 5% and 10% of body weight (BW) to neutral wrist. The interrater and intrarater reliability were calculated with an intraclass correlation coefficient (ICC) with 95% confidence interval (CI) and standard error of measurement (SEM) at 5% BW and 10% BW. The level of scapular winging was tested between 5% BW and 10% BW with a paired t-test. The interrater reliability was shown to be high at 5% BW (ICC(2,k)=.955, 95% CI=.900~.979, SEM=.07) and at 10% BW (ICC(2,k)=.968, 95% CI=.930~.985, SEM=.06). The intrarater reliability was shown to be high at 5% BW (ICC(2,k)=.921, 95% CI=.842~.961, SEM=.09) and at 10% BW (ICC(2,k)=.906, 95% CI=.813~.954, SEM=.10). The level of scapular winging was significantly different between 5% BW and 10% BW. Conclusively, it is demonstrated that the scapulometer is an objective and qualitative measurement tool for scapular winging.

Analysis of Face Direction and Hand Gestures for Recognition of Human Motion (인간의 행동 인식을 위한 얼굴 방향과 손 동작 해석)

  • Kim, Seong-Eun;Jo, Gang-Hyeon;Jeon, Hui-Seong;Choe, Won-Ho;Park, Gyeong-Seop
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.4
    • /
    • pp.309-318
    • /
    • 2001
  • In this paper, we describe methods that analyze a human gesture. A human interface(HI) system for analyzing gesture extracts the head and hand regions after taking image sequence of and operators continuous behavior using CCD cameras. As gestures are accomplished with operators head and hands motion, we extract the head and hand regions to analyze gestures and calculate geometrical information of extracted skin regions. The analysis of head motion is possible by obtaining the face direction. We assume that head is ellipsoid with 3D coordinates to locate the face features likes eyes, nose and mouth on its surface. If was know the center of feature points, the angle of the center in the ellipsoid is the direction of the face. The hand region obtained from preprocessing is able to include hands as well as arms. For extracting only the hand region from preprocessing, we should find the wrist line to divide the hand and arm regions. After distinguishing the hand region by the wrist line, we model the hand region as an ellipse for the analysis of hand data. Also, the finger part is represented as a long and narrow shape. We extract hand information such as size, position, and shape.

  • PDF

Implementation of Low-Power Ubiquitous Health System based on Real-Time Embedded Linux using ZigBee wireless communication (ZigBee를 이용한 실시간 임베디드 리눅스 기반의 저전력형 U-Health 시스템 구현)

  • Kwon, Jong-Won;Ayurzana, Odgerel;Park, Yong-Man;Koo, Sang-Jun;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.436-438
    • /
    • 2007
  • As the sensors and communication technology get advance, the remote health diagnosis for patients and senior persons at home are possible now without visiting doctors in hospitals. A low-power ubiquitous health check device was developed adapting Real-Time Embedded Linux is developed. This ubiquitous device is consisted of three sensors. The wrist type health checking terminal acquires periodically the health data by using a blood pressure sensor, a pulse sensor and a body temperature sensor. It transmits the health data to the access point located at the home center through the ZigBee wireless communication modem. This health data collector or access point device sends the data again to the main server operated in a hospital or health care organization. The health server control continuously the input data and sends an alarm signal to the assigned. doctor and responsible persons using cellular SMS when any dangerous events occur. This wrist type health check device has an embedded linux OS using Intel PAX255 MPU. The developed U-Health system is applicable for checking patients health in remote at home. And their family or related persons in remote site can check the patients health status at any time. They can be assured by receiving SMS record and alarm of emergency case which is transmitted from the health server.

  • PDF

A Study on the Production Conditions of Circular Knit of Domestic Women's Apparel Industry (국내 여성복 업체의 환편니트 제품 생산현황 조사)

  • Oh, Ji-Yeong
    • Fashion & Textile Research Journal
    • /
    • v.18 no.5
    • /
    • pp.637-646
    • /
    • 2016
  • The goal of this study is to provide basic data on developing circular knit basic pattern for women in their 20's. Production conditions of circular knit product pattern making among domestic women's apparel industry was researched, and collected data on sizes and ease amounts from woven and circular knit pattern were compared and analyzed. According to the result of the survey, product measurements adjusted to the actual body size fit for the brand's image were used, and the common problem among manufacturers and consumers regarding circular knit products turned out to be change in size and form due to stretching. For the basic pattern of circular knit, stretching quality was reflected in the woven basic pattern based on plain stitch(single knit) and then dart was removed and ease amount was reduced. The result of looking into size and ease amount about woven and circular knit torso & sleeve block shows that there is a significant difference among chest circumference, hip circumference, bi-shoulder length, interscye back, interscye front, scye depth, upper arm circumference and wrist circumference, and it was clear that circumference and width on the areas around the wrist tended to fit around the body more when circular knit was used instead of woven fabric.

A Case of Radial Nerve Palsy (요골신경마비(撓骨神經痲痺) 치험(治驗) 1례(例))

  • Lee, Se-yun;Lee, Kyung-min;Jung, Tae-young;Seo, Jung-chul;Han, Sang-won
    • Journal of Acupuncture Research
    • /
    • v.20 no.1
    • /
    • pp.236-243
    • /
    • 2003
  • Objective : The purpose of this study is to report the patient with radial nerve palsy, who improved by oriental medical treatment. Methods : The patient was managed by bee venom aqua-acupuncture, sclp acupuncture and herbal medicine. We took picture of the patients's wrist and checked the power of muscles. Results : After 4 week treatment, the movement and power of wrist was restored of nearly normal range. also the numbness of hand was removed. Combined oriental medical treatment can treat radial nerve palsy earlier than other methods. Conclusions : The results suggest that combination of bee venom aqua-acupuncture, scalp acupuncture and herbal medicine is good method for treatment of radial nerve palsy. But further studies are required to concretely prove the effectiveness of this methods for treating radial nerve palsy.

  • PDF

A Case Report of lymphedema due to axillary lymph node dissection (유방암 절제술 후 발생한 림프부종 환자의 치험1례)

  • Kim, Eun-Geol;Yoon, Eun-Hye;Song, Soo-Cheol;Lee, Seong-No;Hwang, Min-Seop
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 2008
  • Objectives : The purpose of this case is to report the improvement of a patient with lymphedema due to axillary lymph node dissection after acupuncture therapy and herbal medicine. Methods : We treated the patient with Dong-Qi acupuncture, herbal medication(木通大安湯), lymph absorption massage, compresses, abdominal breathing. We measured the circumference of the patient's elbow and wrist every day at 6pm. Results : Since being hospitalized, the circumference of the patient' elbow and wrist has been decreased and VAS score has gotten lower gradually. Conclusions : We considered Dong-Qi acupuncture, herbal medication had a useful effect on lymphedema due to axillary lymph node dissection with lymph absorption massage, compresses, abdominal breathing.

  • PDF