• Title/Summary/Keyword: W-target

Search Result 789, Processing Time 0.032 seconds

Development and Characteristics of the x-ray transmission anode tube for the thickness measurement of film (필름 두께 측정용 투과 양극형 x-ray tube의 개발 및 특성)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.240-246
    • /
    • 2008
  • The x-ray transmission anode Ag-target tube was developed to apply for the thickness measurement of film in the thickness range of several tens$\sim$several hundreds ${\mu}m$ and its characteristics were evaluated. The energy distribution and dose of x-ray from Ag-target tube was investigated at the tube voltage near 10 kV, and discussed in comparition with that from W-target tube. The energy distribution and dose of x-rays passing through film were measured with various thickness of Ny and PP film. From these results, it was confirmed that our x-ray tube can be applied for the thickness measurement of film.

Characteristics of the X-ray Fluorescence by the 40kV transmission anode x-ray tube (40kV용 투과양극형 x-ray tube에 의한 X-ray 형광 특성)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.3
    • /
    • pp.247-252
    • /
    • 2008
  • By using the transmission anode x-ray tube developed to apply to the hand-held XRF equipment, we carried out XRF experiment and evaluated the influences of the x-ray tube on XRF spectra. XRF data, which is measured using the W-target and Rh-target tube, were good agreements with the known results. FWHM of Fe $K_{\alpha}$-line measured by W-target tube with the 35 kV-tube voltage and the $40{\mu}A$-tube current was 180 eV. This result reveals that our XRF equipment using the transmission anode x-ray tube is enough for a qualitative analysis of materials. By comparison XRF data with the integrated intensity of x-ray tube, it was confirmed that Rh-target tube is better than W-target tube for application to the hand-held XRF equipment.

Development and Characteristics of the Soft x-ray transmission W-target tube (W-target 투과 양극형 Soft x-ray tube의 개발 및 특성분석)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.305-310
    • /
    • 2007
  • The x-ray transmission W-target tube was developed and its characteristics were evaluated. The continuous x-ray was emitted at the tube voltage less than 12kV, and the characteristic x-ray was emitted more than 12kV. From the measurement of the energy distribution and dose of x-ray, it was confirmed that our results are a good agreement with the blown ones. Moreover, in comparison with commercial x-ray tube, it was also found that the characteristics of our x-ray tube is better than the commercial one. Therefore we confirmed that the x-ray tube developed in this study is so good that it can be commercialized.

Ultrasonic Target Strength of Cyprinus Carpio in Accordance with Body Length and Body Weight (이스라엘 잉어 Cyprinus Carpio의 체장 , 체중별 초음파 표적강도에 관한 연구)

  • Shin, Hyoung-Ho;Yoon, Gab-Dong;Park, Hae-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.4
    • /
    • pp.191-199
    • /
    • 1989
  • Research on the acoustic properties of fish has been carried out by a number of scientific workers from the earliest days of applying acoustic techniques to fish biomass estimates. This paper describes measurements of the target strength of Cyprinus Carpio, which measurements made at 50KHz in the experimental water tank. The results obtained are as follows: 1. The target strength(dB) of the fish has a directivity pattern quite similar to that of a transducer. The maximum value of target strength(dB) is obtained when the fish is insonified to its head-tail axis either from the dorsal or from the ventral side. 2. Empirical relationship between target strength(dB) and body length(cm) of the fish can be estimated as TS=20 Log L-65.4 where TS is the target strength of the fish and L is the body length of the fish. 3. The relationship between target strength(dB) and body weight(g) of the fish can be estimated as TS=6.7 Log W-53.7 where W is body weight of the fish.

  • PDF

A W-band Cassegrain Antenna of the Target Detecting Fuze Sensor (표적감지 신관센서용 W-대역 카세그레인 안테나)

  • Jung, Myung-Suk;Uhm, Won-Young;Kim, Wan-Joo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.101-108
    • /
    • 2006
  • This paper describes the design, fabrication, and measured results of a W-band Cassegrain antenna suitable for the target detecting fuze sensor. The Cassegrain antenna is designed using MATLAB and MWS of CST. We use the multi-mode horn antenna as a feeder. The measurement results are as follows: The gain is about 41dB; SLL is 17.7dB; 3dB beamwidth is about $1.51^{\circ}$ in E-plane and $1.45^{\circ}$ in H-plane. The magnitude of leakage signals is about 43.5mVpp when the fabricated antenna and the transceiver of the fuze sensor ire combined. As a result, the designed W-band Cassegrain antenna could be quite applicable to the target detecting fuze sensor.

The study on target tracking filter using interacting multiple model for tracking maneuvering target (기동표적 추적을 위한 상호작용다수모델 추적필터에 관한 연구)

  • Kim, Seung-Woo
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.137-144
    • /
    • 2007
  • Fire Control System(FCS) errors can be classified as hardware errors and software errors, and one of the software errors is from target tracking filter which estimates target's location, velocity, acceleration, and so on. It affects function of ballistic calculation equipment significantly. For gun to form predicted hitting point accurately and enhance hitting rate, we need status information of target's future location. Target tracking filter algorithms consist of Single Singer Model, Fixed Gain filter algorithm, IMM, PBIMM and so on. This paper will design IMM tracking filer, which is going to be! applied to domestic warship. Target tracking filter using CV model, Song model and CRT model for IMM tracking filter is made, and tracking ability is analyzed through Monte-Carlo simulation.

  • PDF

Effect of sputtering parameters and targets on properties of ZnO:Al thin films prepared by reactive DC magnetron sputtering (직류 반응성 sputtering법으로 제막된 ZnO:Al 박막의 물성에 미치는 증착조건 및 타겟의 영향)

  • 유병석;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.4
    • /
    • pp.592-598
    • /
    • 1998
  • AZO(Aluminum doped Zinc Oxide) thin films were fabricated by reactive DC magnetron sputtering method using zinc metal target (Al 2%) and zinc oxide target ($Al_2O_3\;2%$) respectively. The intermediate condition with optimum transmittance and conductivity was obtained by controlling the sputtering parameters. Oxygen gas ratio for this condition was $0.5{\times}10^{-2}~1.0{\times}10^{-2}$ in oxide target and. In case of metal target, this optimum oxygen gas ratio at the applied power of 0.6 kW and 1.0 kW was 0.215~0.227 and 0.305~0.315, respectively. The resistivity of AZO film deposited was obtained $1.2~1.4{\times}10^{-3} {\Omega}{\cdot}$cm as deposited state regardless of target species.

  • PDF

The study on target recognition method to process real-time in W-band mmWave small radar (밀리미터파대역(W-대역)공대지 레이다의 이중편파 채널을 활용한 지상 표적 식별 기법에 관한 연구)

  • Park, Sungho;Kong, Young-Joo;Ryu, Seong-Hyun;Yoon, Jong-Suk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.3
    • /
    • pp.61-69
    • /
    • 2018
  • In this paper, we propose a method for recognizing ground target using dual polarization channels in millimeter waveband air-to-surface radar. First, the Push-Broom target detection method is described and the received signal is modeled considering flight-path scenario of air-to-surface radar. The scattering centers were extracted using the RELAX algorithm, which is a time domain spectral estimation technique, and the feature vector of the target was generated. Based on this, a DB for 4 targets is constructed. As a result of the proposed method, it is confirmed that the target classification rates is improved by more than 15% than the single channel using the data of the dual polarization channel.

Design and Fabrication of a W-band FMCW Radar for the Metal Target Detection Under the Ground Clutter Environment (지면 클러터 환경에서 금속표적감지를 위한 W-대역 FMCW 레이더의 설계 및 제작)

  • Park Jung-Dong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.3 s.18
    • /
    • pp.93-100
    • /
    • 2004
  • In this paper, we describe the design, fabrication, and test results of a W-band FMCW radar for the metal target detection under the ground clutter environment. In order to detect metal targets on the ground, we used a single cassegrain antenna with the beamwidth of $1.45^{\circ}$ which forms pencil-beam footprint on the ground. A log envelope detector was applied to improve radar performance in the severe ground clutter known as Weibull and log normal clutter. The designed FMCW radar can acquire altitude information from the ground clutter with $\sigma_0=-23dB$ at the height of 160m. The fabricated W-band FMCW radar transmits 11 dBm power and the dynamic range of the receiver is from -106dBm to -30dBm. The performances of the fabricated sensors were tested out in the fields and detected a car target of 200m apart on the grass.

The invariant design of planar magnetron sputtering TFT-LCD

  • Yoo, W.J.;Demaray, E.;Hosokawa;Pethe, R.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.2
    • /
    • pp.101-106
    • /
    • 1999
  • The main consideration factor to design a magnetron of the sputtering system for TFT-LCD metallization is high sheet resistance (Rs) uniformity which is provided by the high target erosion and high current efficiency. The present study has developed a rectangular magnetron for TFT-LCD to bve considered full target erosion and high film uniformity. After an aluminum-2 at.% and alloy target was installed in a magnetron source and the film was deposited on the glass of 600${\times}$720 mm, the Rs uniformity of the deposited film was measured as functions of the magnet tilt and magnet scanning configuration. And the target erosion profile was observed with the target voltage. When sputtered at 4mtorr and 10kW, the magnet tilt for the high Rs uniformity of 8.38% was 7mm. The plasma voltage at the dwell home and end for full-face target erosion, when scanned the magnetron was 120% compared to the mean voltage of the other area.

  • PDF