• Title/Summary/Keyword: Volumetric loading

Search Result 140, Processing Time 0.026 seconds

TREATMENT OF HIGH-CONCENTRATION SWINE WASTEWATER BY ANAEROBIC DIGESTION AND AN AQUATIC PLANT SYSTEM

  • Kim, B.U.;Kwon, J.H.
    • Environmental Engineering Research
    • /
    • v.11 no.3
    • /
    • pp.134-142
    • /
    • 2006
  • The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system was investigated. Anaerobic digestion of swine wastewater gave volatile solids (VS) removal efficiencies of 43.3%, 52.1% and 54.5% for hydraulic retention times (HRTs) of 20, 30, 40 days, respectively. The removal efficiencies of VS, total chemical oxygen demand (TCOD) and soluble chemical oxygen demand (SCOD) decreased with increasing VS volumetric loading rate (VLR). Higher organic removal efficiency was observed at longer HRTs for the same VS volumetric loading rate. As VS volumetric loading rate increased, biogas production increased and the methane content of the biogas decreased. Experiments using duckweed (Lemna species) as an aquatic macrophyte gave the following results. In the case of nitrogen, removal efficiency was above 60% and effluent concentration was below 10.0 mg/L when the influent ammonia-N loading was about $1.0\;g/m^2/day$. In the case of phosphorus, removal efficiency was above 55% and effluent concentration was below 2.0 mg/L when the influent $PO_4$-P loading was about $0.15\;g/m^2/day$. In addition, crude protein and phosphorus content of duckweed biomass increased from 15.6% to 41.6% and from 0.8% to 1.6%, respectively, as the influent nutrient concentration increased. The treatment of high-strength swine wastewater by anaerobic digestion combined with an aquatic plant system offers good performance in terms of organics and nutrient removal for relatively low operation and maintenance costs. The results indicate that under appropriate operational conditions, the effluent quality is within the limits set by Korean discharge criteria.

Stress-Strain Behavior of Confined Concrete Columns according to Transverse Reinforcement Volumetric Ratio (횡방향 구속철근비에 따른 교각요소부재의 응력-변형 거동)

  • Oh Byung Hwan;Kim Ki Wan;Chioi Seung Won;Lee Jae Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.37-40
    • /
    • 2004
  • An experimental study was conducted to investigate the stress-strain behavior of confined concrete columns according to transverse reinforcement volumetric ratio. Uniaxial loading tests of eleven column specimens$(250\times100\times500mm)$ with rectangular section were conducted to study effect of confinement. The main variables in this test are transverse reinforcement volumetric ratio and cross tie arrangement. the results indicate that the strength and the ductility of confined concrete columns are subjected to transverse reinforcement volumetric ration and cross tie arrangement.

  • PDF

An Analysis of Poisson's Ratio Behaviors by Uniaxial Compressive Loading-reloading Test - On the Sedimentary Rocks of Kyungsang Basin - (일축압축 하에서 반복재하에 따른 포아송비의 거동분석 - 경상분지 퇴적암을 대상으로 -)

  • Lee, Jong-Suok;Moon, Jong-Kyu;Choi, Woong-Eui
    • Tunnel and Underground Space
    • /
    • v.23 no.1
    • /
    • pp.66-77
    • /
    • 2013
  • This paper deals with Poisson's ratio and volumetric strain behavior on loading-reloading terms under uniaxial condition targeting 404 individual rocks, which include sedimentary rocks as sandstone, shale, mudstone, conglomerate and tuff on Kyungsang basin. Poisson' ratio demonstrates increase, convergence and decrease behavior according to the increase in load, which results in preponderance of increase behavior. Volumetric strain demonstrates normal, positive and negative behavior according to the increase in load, which results in preponderance of normal behavior. On practice, Poisson's ratio can be indicative of high or low values with low values of design load. Consequently, a careful selection of results in in-situ sample experiment should be made and varying design conditions should be considered.

The drained deformation characteristics of sand subjected to lateral cyclic loading

  • Junhua Xiao;Jiapei Ma;Jianfeng Xue;Zhiyong Liu;Yingqi Bai
    • Geomechanics and Engineering
    • /
    • v.34 no.5
    • /
    • pp.481-489
    • /
    • 2023
  • Drained cyclic triaxial tests were conducted on a saturated sand to examine its deformation characteristics under either axial or lateral cyclic loading condition. To apply lateral cyclic loading, the cell pressure was cycled while maintaining a constant vertical stress. The strain accumulations and flow direction in the soil were presented and discussed considering various initial stress ratios (η0), cyclic stress amplitudes and cyclic stress paths. The results indicate that axial strain accumulation shows an exponential increase with the maximum stress ratio (ηmax). The initial deviatoric stress has comparable effects with lateral cyclic stress amplitude on the accumulated axial strain. In contrast, the accumulated volumetric strain is directly proportional to the lateral cyclic stress amplitude but not much affected by η0 values. Due to the anisotropy of the soil, the accumulated axial and lateral bulging strains are greater in lateral cyclic loading when compared to axial cyclic loading even though ηmax is the same. It is also found that ηmax affects soil's lateral deformation and increasing the ratio could change the lateral deformation from contraction to bulging. The flow direction depends on ηmax in the sand under lateral cyclic loading, regardless of η0 values and the cyclic stress amplitudes, and a large ηmax could lead to great deviatoric strain but a little volumetric strain accumulation.

Post-Cyclic Deformation Behavior of Non-Liquefied Weathered Soils (반복재하후 미액상화 풍화토 지반의 변형 거동)

  • 최연수;정충기
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.485-492
    • /
    • 2001
  • Weathered soil is one of the most representative soils in Korea. In this study, a series of cyclic triaxial tests was carried out to predict the post-cyclic deformation behavior of weathered soils in case of non-liquefaction. Excess pore pressure response during cyclic loading and volumetric strain during the dissipation of excess pore pressure were measured varying the confining pressure, relative density and cyclic stress ratio. Based on the test results, it Is found that the modified excess pore pressure ratio, excess pore pressure ratio normalized by cyclic stress ratio, is uniquely correlated with the number of cycles irrespective of confining pressure and cyclic stress ratio. Using the newly proposed MEPPR(modified excess pore pressure ratio) concept, it is possible to easily evaluate the excess pore pressure and the settlement of weathered soils due to cyclic loading by greatly reduced number of tests. It is also verified that the reconsolidation volumetric strain is independent of the way how the excess pore pressure was generated.

  • PDF

Reaction Characteristics and Kinetics for Treatment of Wastewater Containing Phenol (Phenol 함유 폐수의 처리를 위한 반응 특성과 속도론)

  • Kang, Sun-Tae;Kim, Jeong-Mog
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.124-130
    • /
    • 1997
  • Wastewater containing phenol was treated using Pseudomonas sp. B3 in continuous reactor, reaction characteristics and kinetics according to variation of volumetric loading rate in continuous reactor were studied. The removal efficiencies of phenol were more than 99% at the whole range of experiment, and those of COD were 97% at the volumetric loading rate, $0.96kg/m^3{\cdot}d$ and 88% at $3.0kg/m^3{\cdot}d$, respectively. Kinetics constants of $q_m$, $K_s$, Y and $K_d$ were obtained 0.901 l/d, 0.620mg/l, 0.659 and 0.219 l/d, respectively. As compared with to constants of standard activated sludge process, these constants were remarkably different because of toxicity and inhibition of phenol to microbes. And also, kinetics constants of oxygen utilization, a, and b, were shown 0.384 kg $O_2/kg$ phenol and 0.029 l/d.

  • PDF

Comparison of the Nitrification Efficiencies of Three Biofilter Media in a Freshwater System

  • Harwanto, Dicky;Oh, Sung-Yong;Jo, Jae-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.363-369
    • /
    • 2011
  • Total ammonia nitrogen (TAN) removal efficiencies of a sand filter (SF), polystyrene microbead filter (PF), and Kaldnes bead filter (KF) media were evaluated under ammonia loading rates of 5, 25, and 50 g $m^{-3}day^{-1}$. The volume of each filter media tested was 7 L, and the water flow rate for all filter media was 24 L/min. The specific surface areas of the SF, PF, and KF were 7,836, 3,287, and 500 $m^2/m^3$, respectively. Sand was fluidized and the other two media were trickle filtered. The volumetric TAN removal rate increased with increasing ammonia loading rate for all filter media. Mean volumetric TAN removal rates under the ammonia loading rates of 5, 25, and 50 g $m^{-3}day^{-1}$ in SF (39.3, 168.6, and 322.7 g $m^{-3}day^{-1}$, respectively) were higher than those in PF (35.0, 157.4, and 310.5 g $m^{-3}day^{-1}$, respectively) and KF (32.1, 142.5, and 288.1 g $m^{-3}day^{-1}$, respectively). These results were related to differences in the specific surface areas of the filter media. PF was the most economic media for efficiently removing TAN.

Recompression Properties of Sand in Post-Liquefaction Process According to Relative Density and Cyclic Loading History (상대밀도와 반복전단이력의 차이에 의한 모래의 액상화 후 재압축 특성)

  • Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2012
  • Ground failure by liquefaction can occur not only during shaking but also as the result of the post-liquefaction process after an earthquake. During the process of ground deformation and failure, excess pore water pressure in soil is redistributed, which can then lead to changes in the effective stress of soils. Therefore, in order to provide a further understanding of the phenomenon, we have to estimate the properties of effective stress during the recompression process in post-liquefaction as well, not only the total amount of pore water drained. The primary objectives of this study are to determine and compare the recompression properties in the post-liquefaction process in terms of the relationship between volumetric strains and mean effective stresses under the various conditions of relative density and shear stress history. In all experimental cases, the volumetric strains increase greatly in the low effective stress level, almost to the zero zone, and granite soil, which has fine grains, undergoes gradual changes in the relationship between volumetric strains and mean effective stresses compared with fine sand. And, we can also find that recompression properties in the post-liquefaction process by cyclic loading depend highly on the dissipation energy and maximum shear strain, and this fact can be obtained in all cases regardless of the existence of fine content, relative density, and loading history. Especially, granite soil having fine grains can be defined uniformly in the relationship between dissipation energy and maximum volumetric strain, while fine sand cannot be so uniformly defined.

The Effect of Sulfur/Limestone Ratio on the Efficiency of Sulfur-Utilizing Denitrification (황/석회석 충전비가 황-이용 탈질효율에 미치는 영향)

  • Shin, Hyung-Soon;Lee, Il-Su;Hwang, Yong-Yoo;Bae, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.271-280
    • /
    • 2000
  • This study was conducted to determine the applicable loading rate and to evaluate the possibility of using limestones as an alkalinity source for the removal of ${NO_3}^{-}-N$ remaining after denitrification/nitrification process with the down-flow sulfur packed bed reactor(SPBR). The pretreated sewage was fed to SPBR. Three SPBRs were filled with elemental sulfur particles and limestones and the volumetric ratios of sulfur to limestone were 0%, 12.5% and 25% for R-0%, R-12.5% and R-25%, respectively. The applicable loading rate was evaluated increasing flow rate with influent ${NO_3}^{-}-N$ concentration of 20 mg/L. For R-0% with external alkalinity supply, denitrification efficiency was greater than 96% up to loading rate of $354.8g\;{NO_3}^{-}-N/m^3{\cdot}day$, and corresponding EBCT was 1.4hr. For R-12.5% and R-25%, where alkalinity was supplied by the limestone filled in the reactor, denitrification efficiency was greater than 94% up to loading rate of $283.8g\;{NO_3}^{-}-N/m^3{\cdot}day$, and corresponding EBCT was 1.7hr. The slightly better performance of R-12.5 compared to R-25 suggests that the volumetric sulfur to limestone ratio of 12.5% was enough for the supply of alkalinity required for sulfur-utilizing denitrification. DO was appeared not showing inhibitory effect on sulfur-utilizing denitrification. The clogging of SPBR caused by the produced gas can effectively be eliminated by regular introduction of treated water in up-flow mode.

  • PDF

A Study on the Biological Nitrogen Removal of the Chemical Fertilizer Wastewater Using Jet Loop Reactor (Jet Loop 반응기를 이용한 화학비료폐수의 생물학적 질소제거 연구)

  • Seo Jong-Hwan;Lee Chul-Seung
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.157-165
    • /
    • 2005
  • This study was conducted to determine optimum design parameters in nitrification and denitrfication of chemical fertilizer wastewater using pilot plant, Jet Loop Reactor. The chemical fertilizer wastewater which contains low amounts of organic carbon and has a high nitrogen concentration requires a post-denitrfication system. Organic nitrogen is hydrolyzed above $86\%$, and the concentration of organic nitrogen was influent wastewater 126mg/L and of effluent wastewater 16.4mg/L, respectively. The nitrification above $90\%$ was acquired to TKN volumetric loading below $0.5\;kgTKN/m^3{\cdot}d$, TKN sludge loading below $0.1\;kgTKN/kgVSS{\cdot}d$ and SRT over 8days. The nitrification efficiency was $90\%$ or more and the maximum specific nitrification rate was $184.8\;mgTKN/L{\cdot}hr$. The denitrification rate was above $95\%$ and the concentration of $NO_3-N$ was below 20mg/L. This case was required to $3\;kgCH_3OH/kgNO_3-N$, and the effluent concentration of $NO_3^--N$ was below 20mg/L at $NO_3^--N$ volumetric loading below $0.7\;kgNO_3^--N/m^3{\cdot}d$ and v sludge loading below $0.12\;kgNO_3^-N/kgVSS{\cdot}d$. At this case, the maximum sludge production was $0.83\;kgTS/kgT-N_{re}$ and the specific denitrfication rate was $5.5\;mgNO_3-N/gVSS{\cdot}h$.