• Title/Summary/Keyword: Volume quantification

Search Result 139, Processing Time 0.024 seconds

Experimental In-Vivo Models Used in Fat Grafting Research for Volume Augmentation in Soft Tissue Reconstruction

  • Lujan-Hernandez, Jorge;Appasani, Raghu;Sullivan, Kylee;Siegel-Reamer, Leah;Lalikos, Janice F.
    • Archives of Plastic Surgery
    • /
    • v.44 no.5
    • /
    • pp.361-369
    • /
    • 2017
  • As the popularity of fat grafting research increases, animal models are being used as the source of pre-clinical experimental information for discovery and to enhance techniques. To date, animal models used in this research have not been compared to provide a standardized model. We analyzed publications from 1968-2015 to compare published accounts of animal models in fat grafting research. Data collected included: species used, graft characteristics (donor tissue, recipient area, amount injected, injection technique), time of sacrifice and quantification methods. Mice were most commonly used (56% of studies), with the "athymic nude" strain utilized most frequently (44%). Autologous fat was the most common source of grafted tissue (52%). Subcutaneous dorsum was the most common recipient site (51%). On average, $0.80{\pm}0.60mL$ of fat was grafted. A single bolus technique was used in 57% of studies. Fat volume assessment was typically completed at the end of the study, occurring at less than 1 week to one year. Graft volume was quantified by weight (63%), usually in conjunction with another analysis. The results demonstrate the current heterogeneity of animal models in this research. We propose that the research community reach a consensus to allow better comparison of techniques and results. One example is the model used in our laboratory and others; this model is described in detail. Eventually, larger animal models may better translate to the human condition but, given increased financial costs and animal facility capability, should be explored when data obtained from small animal studies is exhausted or inconclusive.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Development of Simplified Computer Program for the Design of Size and Culvert Outlet in Detention Pond (저류지의 규모 및 방류암거의 설계를 위한 간편프로그램 개발)

  • Lee, Jae Joon;Ahn, Jae Chan;Kim, Byung Il
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.7
    • /
    • pp.587-598
    • /
    • 2014
  • Recently runoff reduction facilities such as detention ponds were rarely used and limited primarily to cases. A specific installation criteria and method of design for runoff reduction facilities is insignificant in our country. Also it has difficult problems with quantification. A detention pond being installed at outfalls and generalized in our country is adopted as basic form with infiltration facilities because quantification index for runoff reduction facilities have not been developed. A processing of detention pond design has to determinate storage volume and outlet form is very complex and wasting human resources and time in the planning step. In this study, we have been unified FFC11-SimPOND being able to simply calculate size with simplified design method of culvert outlet and made a computing model (SimPOND-CO) for practical users.

Quantitative Determination and Antioxidant Effects of Cheonwangbosimdan (LC-MS/MS를 이용한 천왕보심단(天王補心丹)의 함량분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.4
    • /
    • pp.300-314
    • /
    • 2014
  • An ultra-performance liquid chromatography-electrospray ionization-mass spectrometer (UPLC-ESI-MS) method was established for the simultaneous quantification of eighteen marker compounds in traditional Korean formula, Cheonwangbosimdan (CWBSD). In addition, we evaluated the antioxidant effects of CWBSD. Eighteen marker components were separated on a UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$) and kept at $45^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as mobile phase. The flow rate was 0.3 mL/min and the injection volume was $2.0{\mu}L$. The antioxidant activities of CWBSD were assessed by measuring free radical scavenging activities on 2,2'-azinobis-3-ethylbenzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The calibration curves of all analytes showed good linearity (correlation coefficient ${\geq}0.9937$) within the test ranges. The limits of detection and quantification for the 18 marker compounds were 0.01-4.71 ng/mL and 0.03-14.13 ng/mL, respectively. The contents of the 18 compounds in CWBSD extract ranged from none to $1701.00{\mu}g/g$. The CWBSD showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction ($RC_{50}$) against ABTS and DPPH radicals were $149.42{\mu}g/mL$ and $339.24{\mu}g/mL$.

Reproducibility of the Assessment of Myocardial Function Using Gated Tc-99m-MIBI SPECT and Quantitative Software (게이트 Tc-99m-MIBI SPECT와 Cedars 소프트웨어를 이용한 심근 기능 측정의 재현성)

  • Lee, Dong-Soo;Cheon, Gi-Jeong;Ahn, Ji-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.403-413
    • /
    • 1998
  • Purpose: We investigated reproducibility of the quantification of left ventricular volume and ejection fraction, and grading of myocardial wall motion and systolic thickening when we used gated myocardial SPECT and Cedars quantification software. Materials and Methods: We performed gated myocardial SPECT in 33 consecutive patients twice in the same position after Tc-99m-MIBI SPECT We used 16 frames per cycle for the gating of sequential Tc-99m-MIBI SPECT. After reconstruction, we used Cedars quantitative gated SPECT and calculated ventricular volume and ejection fraction (EF). Wall motion was graded using 5 point score. Wall thickening was graded using 4 point score. Coefficient of variation for re-examination of volume and fraction were calculated. Kappa values (k-value) for assessing reproducibility of wall motion or wall thickening were calculated. Results: Enddiastolic volumes (EDV) ranged from 58 ml to 248 ml (122 ml +/- 42 ml), endsystolic volumes (ESV) from 20 ml to 174 ml (65 ml +/- 39 ml), and EF from 20% to 65% (51% +/- 14%). Geometric mean of standard deviations of 33 patients was 5.0 ml for EDV, 3.9 ml for ESV and 1.9% for EF. Their average differences were not different from zero (p>0.05). k-value for wall motion using 2 consecutive images was 0.76 (confidence interval: 0.71-0.81). k-value was 0.87 (confidence interval: 0.83-0.90) for assessment of wall thickening. Conclusion: We concluded that quantification of functional indices, assessment of wall motion and wall thickening using gated Tc-99m-MIBI SPECT was reproducible and we could use this method for the evaluation of short-acting drug effect.

  • PDF

A Preliminary Quantification of $^{99m}Tc$-HMPAO Brain SPECT Images for Assessment of Volumetric Regional Cerebral Blood Flow ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 영상의 부위별 체적 혈류 평가에 관한 기초 연구)

  • Kwark, Cheol-Eun;Park, Seok-Gun;Yang, Hyung-In;Choi, Chang-Woon;Lee, Kyung-Han;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.170-174
    • /
    • 1993
  • The quantitative methods for the assessment of the cerebral blood flow using $^{99m}Tc$-HMPAO brain SPECT utilize the measured count distribution in some specific reconstructed tomographic slice or in algebraic summation of a few neighboring slices, rather than the true volumetric distribution, to estimate the relative regional cerebral blood flow, and consequently produce the biased estimates of the true regional cerebral blood flow. This kind of biases are thought to originate mainly from the arbitrarily irregular shape of the cerebral region of interest(ROI) which are analyzed. In this study, a semi-automated method for the direct quantification of the volumetric regional cerebral blood flow estimate is proposed, and the results are compared to those calculated by the previous planar approaches. Bias factors due to the partial volume effect and the uncertainty in ROI determination are not considered presently for the methodological comparison of planar/volumetric assessment protocol.

  • PDF

Impact of Model-Based Iterative Reconstruction on the Correlation between Computed Tomography Quantification of a Low Lung Attenuation Area and Airway Measurements and Pulmonary Function Test Results in Normal Subjects

  • Kim, Da Jung;Kim, Cherry;Shin, Chol;Lee, Seung Ku;Ko, Chang Sub;Lee, Ki Yeol
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1187-1195
    • /
    • 2018
  • Objective: To compare correlations between pulmonary function test (PFT) results and different reconstruction algorithms and to suggest the optimal reconstruction protocol for computed tomography (CT) quantification of low lung attenuation areas and airways in healthy individuals. Materials and Methods: A total of 259 subjects with normal PFT and chest CT results were included. CT scans were reconstructed using filtered back projection, hybrid-iterative reconstruction, and model-based IR (MIR). For quantitative analysis, the emphysema index (EI) and wall area percentage (WA%) were determined. Subgroup analysis according to smoking history was also performed. Results: The EIs of all the reconstruction algorithms correlated significantly with the forced expiratory volume in one second (FEV1)/forced vital capacity (FVC) (all p < 0.001). The EI of MIR showed the strongest correlation with FEV1/FVC (r = -0.437). WA% showed a significant correlation with FEV1 in all the reconstruction algorithms (all p < 0.05) correlated significantly with FEV1/FVC for MIR only (p < 0.001). The WA% of MIR showed the strongest correlations with FEV1 (r = -0.205) and FEV1/FVC (r = -0.250). In subgroup analysis, the EI of MIR had the strongest correlation with PFT in both eversmoker and never-smoker subgroups, although there was no significant difference in the EI between the reconstruction algorithms. WA% of MIR showed a significantly thinner airway thickness than the other algorithms ($49.7{\pm}7.6$ in ever-smokers and $49.5{\pm}7.5$ in never-smokers, all p < 0.001), and also showed the strongest correlation with PFT in both ever-smoker and never-smoker subgroups. Conclusion: CT quantification of low lung attenuation areas and airways by means of MIR showed the strongest correlation with PFT results among the algorithms used, in normal subjects.

Automatic Left Ventricle Segmentation by Edge Classification and Region Growing on Cardiac MRI (심장 자기공명영상의 에지 분류 및 영역 확장 기법을 통한 자동 좌심실 분할 알고리즘)

  • Lee, Hae-Yeoun
    • The KIPS Transactions:PartB
    • /
    • v.15B no.6
    • /
    • pp.507-516
    • /
    • 2008
  • Cardiac disease is the leading cause of death in the world. Quantification of cardiac function is performed by manually calculating blood volume and ejection fraction in routine clinical practice, but it requires high computational costs. In this study, an automatic left ventricle (LV) segmentation algorithm using short-axis cine cardiac MRI is presented. We compensate coil sensitivity of magnitude images depending on coil location, classify edge information after extracting edges, and segment LV by applying region-growing segmentation. We design a weighting function for intensity signal and calculate a blood volume of LV considering partial voxel effects. Using cardiac cine SSFP of 38 subjects with Cornell University IRB approval, we compared our algorithm to manual contour tracing and MASS software. Without partial volume effects, we achieved segmentation accuracy of $3.3mL{\pm}5.8$ (standard deviation) and $3.2mL{\pm}4.3$ in diastolic and systolic phases, respectively. With partial volume effects, the accuracy was $19.1mL{\pm}8.8$ and $10.3mL{\pm}6.1$ in diastolic and systolic phases, respectively. Also in ejection fraction, the accuracy was $-1.3%{\pm}2.6$ and $-2.1%{\pm}2.4$ without and with partial volume effects, respectively. Results support that the proposed algorithm is exact and useful for clinical practice.

Feasibility of On-chip Detection of Endotoxin by LAL Test

  • Lee, Eun-Kyu;Suh, Chang-Woo;Hwang, Sang-Youn;Park, Hyo-Jin;Seong, Gi-Hoon;Ahn, Yoo-Min;Kim, Yang-Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.132-136
    • /
    • 2004
  • The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (lab-on-a-chip) prototype, 62mm (L) ${\times}$ 18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2mm (W) ${\times}$ 44.3mm (L) ${\times}$ 100 $\mu\textrm{m}$ (D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip thickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 to ca. 4.4 ${\mu}$L. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.

Easy and rapid quantification of lipid contents of marine dinoflagellates using the sulpho-phospho-vanillin method

  • Park, Jaeyeon;Jeong, Hae Jin;Yoon, Eun Young;Moon, Seung Joo
    • ALGAE
    • /
    • v.31 no.4
    • /
    • pp.391-401
    • /
    • 2016
  • To develop an easy and rapid method of quantifying lipid contents of marine dinoflagellates, we quantified lipid contents of common dinoflagellate species using a colorimetric method based on the sulpho-phospho-vanillin reaction. In this method, the optical density measured using a spectrophotometer was significantly positively correlated with the known lipid content of a standard oil (Canola oil). When using this method, the lipid content of each of the dinoflagellates Alexandrium minutum, Prorocentrum micans, P. minimum, and Lingulodinium polyedrum was also significantly positively correlated with the optical density and equivalent intensity of color. Thus, when comparing the color intensity or the optical density of a sample of a microalgal species with known color intensities or optical density, the lipid content of the target species could be rapidly quantified. Furthermore, the results of the sensitivity tests showed that only $1-3{\times}10^5cells$ of P. minimum and A. minutum, $10^4cells$ of P. micans, and $10^3cells$ of L. polyedrum (approximately 1-5 mL of dense cultures) were needed to determine the lipid content per cell. When the lipid content per cell of 9 dinoflagellates, a diatom, and a chlorophyte was analyzed using this method, the lipid content per cell of these microalgae, with the exception of the diatom, were significantly positively correlated with cell size, however, volume specific lipid content per cell was negatively correlated with cell size. Thus, this sulpho-phospho-vanillin method is an easy and rapid method of quantifying the lipid content of autotrophic, mixotrophic, and heterotrophic dinoflagellate species.