• Title/Summary/Keyword: Volume Flux

Search Result 476, Processing Time 0.213 seconds

A Study on the Ignition Characteristics at Constant Volume Combustion Chamber of LPG (LPG 정적연소실내 점화특성에 관한 연구)

  • 박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.75-82
    • /
    • 2004
  • The allowable exhaust standard has been intensified as a part of the countermeasure to decrease air pollution in the world. As the cars with an alternative fuel starts to get into the spotlight, the cars with low emission has been introduced and exhaust gas regulation forced in this country. These days, LPG vehicles, which infrastructure of fuel was already built up, and CNG vehicles are recognized for alternative fuel cars in this country. In this study, the constant volume combustion chamber was manufactured and used for experiments to obtain the ignition characteristics of LPG fuel and the optimal ignition energy. The experiment measured the combustion characteristics, in regard to the change of combustion variable, and the change of ignition energy. During the combustion of fuel, the maximum temperature inside the combustion chamber is higher when the initial pressure is higher. The burning velocity also seems to have the same characteristic as the temperature. However, the heat flux did not change much with the theoretical correct mixture but the various initial temperature of the combustion chamber. The heat flux got faster and ignition energy bigger as the dwell time of the ignition system expanded. When the dwell time get longer, the ignition energy also increased then fixed. The ignition energy increased as the initial pressure inside the combustion chamber higher. The heat flux got faster as the dwell time expanded.

Characterization of Pervaporation Membranes and Its Operation Parameters for Alcohol Concentration (알코올 농축을 위한 투과증발막의 특성 및 조업변수 연구)

  • 임군택;김현일;김성수
    • Membrane Journal
    • /
    • v.9 no.2
    • /
    • pp.107-113
    • /
    • 1999
  • Alcohol concentration via pervaporation process was performed by using commercial PDMS(polydimethylsiloxane) composite membrane and plasma treated PP(polypropylene) membranes. Effects of operating parameters of pcrvaporation process were examined. With the increase of butanol concentration in the feed, flux and selectivity increased due to the greater affinity of butanol with PDMS than that of water. As the operating temperature increased, free volume as well as the solubilities and diffusivities of alcohol and water increased to result in the greater flux and less selectivity of the membrane. As solubility parameter difference between alcohol and PDMS membrane decreased, high flux and good selectivity were obtained. When PP membrane was plasma treated with methanol, it has 6 times greater flux than PDMS membrane with equivalent separation factor. With the increase of plasma treatment time, flux and selectivity were enhanced. However, excess treatment time caused pore blocking to result in the flux decrease.

  • PDF

A Effect of Fuel Properties on Spray Structure for Dual Orifice Fuel Injector (연료의 물성치 변화가 이중 오리피스 연료 노즐의 분무 구조에 미치는 영향에 관한 연구)

  • Lee, Dong-Hun;Choi, Seong-Man;Park, Jeong-Bae
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.179-188
    • /
    • 2003
  • The spray characteristics of dual orifice injector were investigated under two different fuels through measurement of SMD, number density and volume flux by using PDPA system. In this experiment, we found out that the droplet size and spray structure are strongly depend on fuel density and viscosity.

  • PDF

Numerical Experiments on the Evaluation of Effective Permeability and Tunnel Excavation in the Three Dimensional Fracture Network Model (3차원 균열연결망 모델에서의 유효투수계수 평가 및 터널굴착 지하수 유동해석에 대한 수치실험)

  • 장근무
    • Tunnel and Underground Space
    • /
    • v.8 no.4
    • /
    • pp.275-286
    • /
    • 1998
  • The effective permeability and the representative element volume(REV) of fracture network model were evaluated based on the parameters such as permeability tensor, principal permeability and the direction of principal permeability. The effective permeability ranges between the harmonic mean and the arithmetic mean of the local permeabilities of subdivided blocks. From the numerical experiments, which were for investigating the influence of model volume on the variation of flux for the cubic models, it was found that the variation of flux became reduced as the model volume approached REV. The variation of groundwater flux into the tunnel in the fracture network model was mainly dependent on the ratio of the tunnel length to model size rather than REV. And it was found that groundwater flux into the tunnel was not completely consistent between the fracture network model and the equivalent porous media model, especially when the ratio of the tunnel length to model size is small.

  • PDF

Enhanced Skin Permeation of a New Capsaicin Derivative (DA-5018) from a Binary Vehicle System Composed of Isopropyl-myristate and Ethoxydiglycol

  • Cha, Bong-Jin;Lee, Eung-Doo;Kim, Won-Bae;Chung, Suk-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • v.24 no.3
    • /
    • pp.224-228
    • /
    • 2001
  • DA-5018, a recently synthesized capsaicin analog, appears to possess potent analgesic activity when administered topically. The objective of this study is to test the feasibility of the topical administration of this compound. Specifically, our goal was to identify vehicle system that permit a reasonable transdermal permeation of the compound in mice. Among the vehicles examined, isopropyl myristate (IPM) showed the largest in vitro permeability across the intact skin (83.6 ${\pm}$ 5.42${\mu}$l/$\textrm{cm}^2$/h ). However, due to the limited solubility of DA-5018 in IPM (0.53 mg/ml), the maximal flux from the IPM medium remained at only 44.3 ${\pm}2.87{\mu}$g/$\textrm{cm}^2$/hr. In order to increase the flux, addition of better solvents for DA-5018 was attempted, under the assumption that flux is the result of both solubility and permeability. Ethoxydiglycol (EG) and oleic acid (OA) were selected as examples of food solvents. The addition of IC or OA to IPM at a 1:1 volume ratio resulted in a comparable increase in the solubility of the compound (i.e., to 61.1 and 50.2 mg/ml for EG and OA, respectively). However, the addition of EG at a 1:1 volume ratio, for example, increased the flux 6.3 fold (i.e., $279{\mu}$g/$\textrm{cm}^2$/hr), while OA, at a 1:1 volume ratio, decreased the flux 5 fold (i.e., $9.26{\mu}$g/$\textrm{cm}^2$//hr). The mechanism of this discrepancy between EG and OA was investigated by measuring the permeabilty of DA-5018 across the stratum corneum-removed skin of the mouse, under the hypothesis that the viable skin layer may serve as a barrier for the permeation of lipophilic substances such as DA 5018. The permeability of DA-5018, from the medium of EG or OA, across the viable skin differed greatly for EG ($0.41{\mu}$l/$\textrm{cm}^2$/hr) and OA ($0.086{\mu}$l/$\textrm{cm}^2$/hr), suggesting that a higher permeability across the viable skin layer is needed for the second solvents. The maximum flux across the intact skin was achieved for DA-5018 when EG was added to IPM at a 1:1 volume ratio. Thus, the use of a binary system appears to be the best approach for realizing the transdermal delivery of DA-5018 at a reasonable rate.

  • PDF

EVALUATION OF NUMERICAL APPROXIMATIONS OF CONVECTION FLUX IN UNSTRUCTURED CELL-CENTERED METHOD (비정렬 셀 중심 방법에서 대류플럭스의 수치근사벙법 평가)

  • Myong H.K.
    • Journal of computational fluids engineering
    • /
    • v.11 no.1 s.32
    • /
    • pp.36-42
    • /
    • 2006
  • The existing numerical approximations of convection flux, especially the spatial higher-order difference schemes, in unstructured cell-centered finite volume methods are examined in detail with each other and evaluated with respect to the accuracy through their application to a 2-D benchmark problem. Six higher-order schemes are examined, which include two second-order upwind schemes, two central difference schemes and two hybrid schemes. It is found that the 2nd-order upwind scheme by Mathur and Murthy(1997) and the central difference scheme by Demirdzic and Muzaferija(1995) have more accurate prediction performance than the other higher-order schemes used in unstructured cell-centered finite volume methods.

A Study on the Spray Cooling Characteristics on the Angle of Hot Heat Transfer Surface (고온 열전달면의 각도에 따른 분무냉각특성에 관한 연구)

  • Yoon, D.H.;Kim, K.K.;Kim, M.H.;Oh, C.;Yoon, S.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.8-14
    • /
    • 2001
  • The purpose of this study is to elucidate heat characteristics according to inclination angle of the hot flat plate at the spray cooling. As results of this experiment, the heat flux, the heat transfer coefficient and the cooling speed are increased as the liquid volume flux and subcooled temperature go up. And as the inclination angle of the heat transfer surface is increased, the cooling speed on the inclined flat plate becomes faster. It means that the cooling ability is increased because droplets were excluded by gravity.

  • PDF

Effect of Concentration of Solution and Temperature on Water Flux by Semi-Permeability of Hardened Cement Paste (시멘트경화체의 반투과성에 의한 수분이동에 미치는 용액농도와 환경온도의 영향)

  • 배기선;오상근;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.131-136
    • /
    • 1997
  • It is well known that concrete is typical porous material. We pay attention to Hansen's idea that concrete may be expected to act as semi-permeable membrane, and report the effect of concentration of solution and temperature on water flux in forward osmosis. In order to measuring volume of water flux from distilled water to solution of sodium chloride through hardened cement paste, specially designed apparatus was constructed, and the following result were obtained: (1) hardened cement paste acts as semi-permeable membrane, consequently, water flux in forward osmosis may occur. (2) Rate of water flux is proportion to concentration of dilute solution, and this suggests hardened cement paste is agreeable to the theory of membrane. (3) Effect of temperature on water flux is agreeable to Arrehenius equation and is great.

  • PDF

Atomization Characteristics of Small LRE-Injector Spray According to Injection Pressure Variation (소형 액체로켓엔진 인젝터 분무의 분사압력 변이에 따른 미립화 특성)

  • Jung, Hun;Kim, Jin-Seok;Kim, Jeong-Soo;Park, Jeong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.125-128
    • /
    • 2008
  • Atomization characteristics of small LRE-injector spray are investigated by using dual-mode phase Doppler anemometry (DPDA). Velocity, size, number density, and volume flux were measured at various injection pressures along the radial distance to make a close inquiry into spatial distribution characteristic of spray droplets. As the injection pressure increases, the velocity, turbulence intensity, number density, and volume flux of spray droplets become higher, whereas the droplet size ($D_{10}$ or $D_{32}$) gets smaller. Also, velocity and volume flux are proportional to Sauter mean diameter (SMD, $D_{32}$).

  • PDF

Spray Characteristics of a Pulsed Liquid Jet into a Cross-flow of Air (아음속 횡단 유동장으로 펄스 분사된 액체 제트의 분무특성)

  • Lee, In-Chul;Byun, Young-Wu;Koo, Ja-Ye
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.61-64
    • /
    • 2008
  • The present study of these experiments are close examination of spray characteristics that are continuous liquid jet and modulated pressure pulse liquid jet. The experiments were conducted using water, over a range of cross-flow velocities from 42${\sim}$136 m/s, with injection frequencies of 35.7${\sim}$166.2 Hz. Between continuous cross-flow jet and pressure pulsed cross-flow jet for characteristics of penetration, breakup point, spray angle and macro spray shape are investigated experimentally. In cross-flow field, main parameter of liquid jet for breakup was cross-flow stream rather than pressure pulse frequency. As oscillation of the periodic pressure that could make liquid jet moved up and down, the mixing efficiency was increased. Also, a bulk of liquid jet puff was detected at upper field of liquid surface. So, this phenomenon has a good advantage of mixing spray from concentration of center area to outer area. Because of pressure pulsation frequency, an inclination of SMD for the structured layer was evanescent. Cross-sectional characteristics of SMD at downstream area were non-structured distributions. Then cross-sectional characteristics of SMD size were about same tendency over a range that is effect of spray mixing. The tendency of volume flux value for various frequency of pressure pulse was same distribution. And volume flux was decreased when the frequency of pressure pulse increase.

  • PDF