• Title/Summary/Keyword: Volume Efficiency

Search Result 2,145, Processing Time 0.03 seconds

Quality Characteristics of White Pan Bread with Different Water Types (물의 종류에 따른 식빵의 품질특성)

  • Kim, Yoon-A;Ko, Jae-Youn;Yoo, Se-Ran;Jang, Se-Jin;Kang, Sang-Hyeon;Han, Doo-Won;Kim, Sung-Hwan;Seo, Ji-Hye
    • Culinary science and hospitality research
    • /
    • v.24 no.3
    • /
    • pp.104-112
    • /
    • 2018
  • The purpose of this study was to examine the quality characteristics of white pan bread according to the different types of water (tap water (still water), purified water, still water, light water, classical water, and bold water). Pan breads were statistically analyzed using texture profile analysis, fermentation, texture, suitability, image analysis, color, moisture content, and statistical analysis. This result will contribute to the commercialization of pan bread using various kinds of water. Ultimately, we analyzed the quality characteristics of various kinds of water, depending on the carbonic acid content on the dough and the pan bread, and to derive the optimum kinds and ratios of the water to be applied to the pan bread. As a result of the study, the best findings were obtained with water containing carbonic acid content more than the classical water according to overall characteristics, durability (Width of Tail and Integral), foot efficiency, softness, volume and preference check. Therefore, when white pan bread is produced by using water containing a carbonic acid content (5~7.5 mg/L) or more of the classical water, it affects the quality characteristics and a good obtains positive response to from consumers. In this study, the quality characteristics of pan bread based different kinds of water which were not available in the past, and the quality characteristics of pan bread, which can be used as the basic data for future research, were well analyzed.

Radiofrequency Coil Design for in vivo Sodium Magnetic Resonance Imaging of Mouse Kidney at 9.4T

  • Lim, Song-I;Woo, Chul-Woong;Kim, Sang-Tae;Choe, Bo-Young;Woo, Dong-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.65-70
    • /
    • 2018
  • The objective of this study was to describe a radiofrequency (RF) coil design for in vivo sodium magnetic resonance imaging (MRI) for use in small animals. Accumulating evidence has indicated the importance and potential of sodium imaging with improved magnet strength (> 7T), faster gradient, better hardware, multi-nucleus imaging methods, and optimal coil design for patient and animal studies. Thus, we developed a saddle-shaped sodium volume coil with a diameter/length of 30/30 mm. To evaluate the efficiency of this coil, bench-level measurement was performed. Unloaded Q value, loaded Q value, and ratio of these two values were estimated to be 352.8, 211.18, and 1.67, respectively. Thereafter, in vivo acquisition of sodium images was performed using normal mice (12 weeks old; n = 5) with a two-dimensional gradient echo sequence and minimized echo time to increase spatial resolution of images. Sodium signal-to-noise ratio in mouse kidneys (renal cortex, medulla, and pelvis) was measured. We successfully acquired sodium MR images of the mouse kidney with high spatial resolution (approximately 0.625 mm) through a combination of sodium-proton coils.

Optimization of Drag-sail Storage Inspired from Blossom Method (개화형상을 모사한 가항력 돛 수납최적화)

  • Kim, Heekyung;Jung, Jinwon;Lee, Gunhee;Lee, Dongyun;Choi, Junwoo;Kim, Byungkyu
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.16-21
    • /
    • 2017
  • In this paper, we propose a new folding method (the blossom method) to increase storage efficiency of drag-sail. To resolve the issue caused by increase in the thickness of the sail, we allowed margin space (offset) along the folding line and made holes at the intersection of offset lines to prevent distortion of film. In addition, to verify applicability of the blossom method, we fabricated quarter of the sail by using Mylar film and conducted a deployment experiment. If the blossom method is applied, storage ratio (storage volume: deployed area) is 1: 68.64, that is approximately 1.88 times more than the z-fold method of folding sailing.

Design and SAR Analysis of Wearable Antenna on Various Parts of Human Body, Using Conventional and Artificial Ground Planes

  • Ali, Usman;Ullah, Sadiq;Khan, Jalal;Shafi, Muhammad;Kamal, Babar;Basir, Abdul;Flint, James A;Seager, Rob D.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.317-328
    • /
    • 2017
  • This paper presents design and specific absorption rate analysis of a 2.4 GHz wearable patch antenna on a conventional and electromagnetic bandgap (EBG) ground planes, under normal and bent conditions. Wearable materials are used in the design of the antenna and EBG surfaces. A woven fabric (Zelt) is used as a conductive material and a 3 mm thicker Wash Cotton is used as a substrate. The dielectric constant and tangent loss of the substrate are 1.51 and 0.02 respectively. The volume of the proposed antenna is $113{\times}96.4{\times}3mm^3$. The metamaterial surface is used as a high impedance surface which shields the body from the hazards of electromagnetic radiations to reduce the Specific Absorption Rate (SAR). For on-body analysis a three layer model (containing skin, fats and muscles) of human arm is used. Antenna employing the EBG ground plane gives safe value of SAR (i.e. 1.77W/kg<2W/kg), when worn on human arm. This value is obtained using the safe limit of 2 W/kg, averaged over 10g of tissue, specified by the International Commission of Non Ionization Radiation Protection (ICNIRP). The SAR is reduced by 83.82 % as compare to the conventional antenna (8.16 W/kg>2W/kg). The efficiency of the EBG based antenna is improved from 52 to 74 %, relative to the conventional counterpart. The proposed antenna can be used in wearable electronics and smart clothing.

Finding Frequent Route of Taxi Trip Events Based on MapReduce and MongoDB (택시 데이터에 대한 효율적인 Top-K 빈도 검색)

  • Putri, Fadhilah Kurnia;An, Seonga;Purnaningtyas, Magdalena Trie;Jeong, Han-You;Kwon, Joonho
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.9
    • /
    • pp.347-356
    • /
    • 2015
  • Due to the rapid development of IoT(Internet of Things) technology, traditional taxis are connected through dispatchers and location systems. Typically, modern taxis have embedded with GPS(Global Positioning System), which aims for obtaining the route information. By analyzing the frequency of taxi trip events, we can find the frequent route for a given query time. However, a scalability problem would occur when we convert the raw location data of taxi trip events into the analyzed frequency information due to the volume of location data. For this problem, we propose a NoSQL based top-K query system for taxi trip events. First, we analyze raw taxi trip events and extract frequencies of all routes. Then, we store the frequency information into hash-based index structure of MongoDB which is a document-oriented NoSQL database. Efficient top-K query processing for frequent route is done with the top of the MongoDB. We validate the efficiency of our algorithms by using real taxi trip events of New York City.

Numerical Analysis on the Increasing Temperature Characteristics of Vaporizer Fin for Liquefied Natural Gas with Super Low Temperature (초저온 액화 천연 가스용 기화기 핀의 승온 특성에 관한 수치 해석)

  • Yi, C.S.;Kong, T.W.;Lee, H.D.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.81-87
    • /
    • 2005
  • This study is numerical analysis on the increasing temperature characteristics of vaporizer fin for liquefied natural gas with super low temperature. Existing LNG vaporizers use the direct contact heat transfer mode where the extreme super low temperature LNG of $-162^{\circ}C$ flows inside of the tubes and about $20^{\circ}C$air flows on outside of the fin. Recently, the vaporizers with great enhanced performance compared to conventional type have been developed to fulfill these requirements. The vaporizing characteristic of LNG vaporizer with air as heat source has a fixed iced. These characteristic cause a low efficiency in vaporizer, total plant cost and installing space can be increased. The vaporizing characteristics of LNG via heat exchanger with air are analytically studied for an air heating type vaporizer. This study is intended to supply the design data for the domestic fabrication of the thickness and angle vaporizer fin. Governing conservation equations for mass, momentum and energy are solved by STAR-CD based on an finite volume method and SIMPLE algorithm. Calculation parameter is fin thickness, setup angle and LNG temperature. If the vaporization performance of the early stage and late stage of operating is considered, the case of ${\phi}=90^{\circ}$ was very suitable. In this paper was estimated that the heat transfer was most promoted in case of THF=2mm.

  • PDF

A Method of Generating Traffic Travel Information Based on the Loop Detector Data from COSMOS (실시간신호제어시스템 루프검지기 수집정보를 활용한 소통정보 생성방안에 관한 연구)

  • Lee, Choul-Ki;Lee, Sang-Soo;Yun, Byeong-Ju;Song, Sung-Ju
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.2
    • /
    • pp.34-44
    • /
    • 2007
  • Many urban cities deployed ITS technologies to improve the efficiency of traffic operation and management including a real-time franc control system (i.e., COSMOS). The system adopted loop detector system to collect traffic information such as volume, occupancy time, degree of saturation, and queue length. This paper investigated the applicability of detector information within COSMOS to represent the congestion level of the links. Initially, link travel times obtained from the field study were related with each of detector information. Results showed that queue length was highly correlated with link travel time, and direct link travel time estimation using the spot speed data produced high estimation error rates. From this analysis, a procedure was proposed to estimate congestion level of the links using both degree of saturation and queue length information.

  • PDF

Performance of carbon fiber added to anodes of conductive cement-graphite pastes used in electrochemical chloride extraction in concretes

  • Pellegrini-Cervantes, M.J.;Barrios-Durstewitz, C.P.;Nunez-Jaquez, R.E.;Baldenebro-Lopez, F.J.;Corral-Higuera, R.;Arredondo-Rea, S.P.;Rodriguez-Rodriguez, M.;Llanes-Cardenas, O.;Beltran-Chacon, R.
    • Carbon letters
    • /
    • v.26
    • /
    • pp.18-24
    • /
    • 2018
  • Pollution of chloride ion-reinforced concrete can trigger active corrosion processes that reduce the useful life of structures. Multifunctional materials used as a counter-electrode by electrochemical techniques have been used to rehabilitate contaminated concrete. Cement-based pastes added to carbonaceous material, fibers or dust, have been used as an anode in the non-destructive Electrochemical Chloride Extraction (ECE) technique. We studied the performance of the addition of Carbon Fiber (CF) in a cement-graphite powder base paste used as an anode in ECE of concretes contaminated with chlorides from the preparation of the mixture. The experimental parameters were: 2.3% of free chlorides, 21 days of ECE application, a Carbon Fiber Volume Fraction (CFVF) of 0.1, 0.3, 0.6, 0.9%, a lithium borate alkaline electrolyte, a current density of $4.0A/m^2$ and a cement/graphite ratio of 1.0 for the paste. The efficiency of the ECE in the traditional technique using metal mesh as an anode was 77.6% and for CFVF of 0.9% it was 90.4%, with a tendency to increase to higher percentages of the CFVF in the conductive cement-graphite paste, keeping the pH stable and achieving a homogeneous ECE in the mass of the concrete contaminated with chlorides.

Determination of $^{241}Pu$ in Environmental Samples Using Liquid Scintillation Counting System (액체섬광계수기를 이용한 환경시료중 $^{241}Pu$분석)

  • Lee, Myung-Ho;Hong, Kwang-Hee;Choi, Yong-Ho;Kim, Sang-Bog;Choi, Geun-Sik;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 1996
  • An optimized method for determining beta-emitting $^{241}Pu$ in the presence of alpha-emitting nuclides was developed using a liquid scintillation counting system. Pulse shape analysis (PSA) level was set using pulse-shape discrimination method and the $^{241}Pu$ counting channel was adjusted for maximum value of figure of merit using the 241pu standard source. The volume of scintillant was determined for the maximum value of counting efficiency. This optimized method has been applied to environmental samples to measure concentration of $^{241}Pu$ in soils and mosses. Also it has been identified the origin of Pu deposited in Korea from the activity ratio of $^{241}Pu/^{239,\;240}Pu$.

  • PDF

An Application of Optimum Heat Exchanger for the Grasp on Performance Characteristics of $NH_3$ Refrigeration System

  • Ha Ok Nam;Kwon Il Wook;Hong Suck Ju;Kim Jae Yeol;Lee Jong In;Jeon Sang Sin;Ha Kyung Soo;Lee Seung Jae;Park Chan Soo;Jeong Song Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.2
    • /
    • pp.69-74
    • /
    • 2005
  • Since the use of CFC and HCFC refrigerants is to be restricted due to the depletion of ozone layer, this experiment applies the $NH_{3}$ gas to study the performance characteristics from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1500kPa to 1600kPa by 50kPa and for degree of superheat from $0^{circ}$ to $1^{circ}$ by $10^{circ}$ at each condensing pressure. As a result of experiment, 1) As degree of superheat increased, evaporating pressure of the compressor decreased so equilibrium temperature decreased. And specific volume of refrigerant vapors increased so refrigerant mass flow and heat load of the evaporator decreased. 2) An influence of change of condensing pressure on heat load of the evaporator was insignificant. 3) With the identical degree of superheat, change of compressed temperature was insignificant according to each condensing pressure, so there was little change in enthalpy.4) when the degree of superheat is $0^{circ}$C at each condensing pressure, the refrigeration system has the hi띤est performance.