• Title/Summary/Keyword: Volume Efficiency

Search Result 2,145, Processing Time 0.03 seconds

Effect of Ozone Concentration on AOP Efficiency of Secondary Effluent from Pig Slurry Purification System (오존 접촉농도가 양돈슬러리 2차 처리수의 고도처리 효율에 미치는 영향)

  • Jeong, K.H.;Jeon, S.K.;Ryu, S.H.;Kim, J.H.;Kwag, J.H.;Ann, H.K.;Jeong, M.S.;Yoo, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.181-188
    • /
    • 2011
  • With an increasing livestock population, animal manure production has been steadily increasing in Korea. This trend has forced farmers to spend more money for animal manure treatment in their farm. Therefore, research utilizing animal manure as a renewable resources has become increasingly important. The purpose of this study was to develop a stable advanced wastewater treatment system can be applied to conventional animal wastewater treatment processes and evaluate its contribution to reduce effluent discharge volume by recycling as flushing water. AOP (advanced oxidation process) process improved wastewater treatment efficiency in terms of color, suspended solids (SS) and chemical oxygen demand (COD). Due to the addition of Hydrogen peroxide ($H_2O_2$), pathogens, Salmonella and E. coli, reduction was accomplished. To enhance ozone treatment effect, three levels of ozone test on secondary effluent of pig slurry purification system were conducted. At the level of 5 g/hr, 6.7 g/hr and 8.4 g/hr color of secondary effluent of pig slurry purification system were decreased from 2,433 to 2,199, 2,433 to 1,980 and 2,433 to 243, respectively.

Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads : Effect of Nitrogen Back-flushing Period and Time (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리 : 질소 역세척 주기와 시간의 영향)

  • Hong, Sung Tack;Park, Jin Yong
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.70-79
    • /
    • 2013
  • The $N_2$ back-flushing period (FT) and time (BT) were investigated in hybrid process of ceramic microfiltration and PES (polyethersulfone) beads loaded with titanium dioxide ($TiO_2$) photocatalyst for advanced drinking water treatment in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). As decreasing FT and increasing BT, $R_f$ decreased and J increased, and finally the maximum $V_T$ could be acquired at FT 10 min and BT 30 sec. In FT effect experiment, treatment efficiencies of turbidity and dissolved organic matters (DOM) were the highest at no back-flushing (NBF) because of dramatic membrane fouling. As result of BT effect, the treatment efficiencies were the maximum at BT 30 sec, which was different with the FT result. Because the photocatalyst beads could be cleaned effectively as decreasing FT and increasing BT, turbidity treatment efficiency increased a little from 95.4% to 97.5% as decreasing FT, and from 95.9% to 98.5% as increasing BT. Also DOM treatment efficiency increased from 70.8% to 80.6% as decreasing FT, and from 75.1% to 85.8% as increasing BT. The optimal condition, where the treatment efficiencies and $V_T$ were the maximum, should be FT 10 min and BT 30 sec in our experimental range.

A Study on the Performance of Flat-plate Solar Air Collector and its Application to Grain Drying (평면식 태양열집열기를 이용한 곡물 건조개선에 관한 연구)

  • 민영봉;최규홍
    • Journal of Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.114-125
    • /
    • 1978
  • The use of petroleum fuels in grain drying causes problems of high cost and management. To solve these problems, it is required to study on soLar energy as an alternative to petroleum fuels for grain drying. The purposes of this study were to find out the optimum received area and air flow rate of a flat-plate solar air collector for grain drying and to assess its effects on grain drying with a small grain bin. The results of this study are summarized as follows ; 1. The calculated optimum tilt angles of the collector in the summer and autumn drying seasons were 20 and 50 degress, respectively, in suwon area. 2. The outlet temperature of the collector was $36^\circ C$ on the daily average with the maximum of $36^\circ C$ at 12:00 o clock. Solar radiation on the collector surface was 1.04 ly( 1 langley = 1 cal/$cm^2$) per minute on the daily average and 1.30 ly per minute on the maximum at 11:00am. The thermal efficiency of the collector was 62.4 percent on the daily average, and the air flow-rate per unit receiving are was 1.03 $m^3$/min/$m^2$.4. The calculated optimum receiving area and the air flow-rate per unit cubic volume for paddy in autumn drying season was 2 $m^2$ and 2$m^3$/min , respectively. 5. not significantly difference in the collector efficiency was appeared between the rotating and fixed type of solar collector. 6. For drying of wheat with 0.6 meter of the depth in the bin, approximately 9 hours were required to reduce the moisture content from 21.6% to 13% with air follow rate of 5 $m^3$/min an initial moisture per cubic meter of wheat and with air temperature of $52^\circ C$. 7. In the drying test of rough rice with a turning operation in a grain bin approximately 21 hours were required to reduced the moisture from 21% to 14.5% with airflow rate of 2 $m^3$/min per cubic meter of rice and the air temperature of $43.5^\circ C$. 8. Over-drying at the bottom and less -drying at the top of the grain mass was resulted from the high -temperature of drying air which was obtained from the flat-plate solar collector in this test. An appropriate operation should be prepared for the uniform moisture of the grain in the bin.

  • PDF

A Practical New Technology of Removing Algal Bloom: K-water GATe Water Combine (조류(藻類)제어를 위한 실용적 신기술 : K-water 녹조수상콤바인)

  • Shin, Jae-Ki;Kim, Hojoon;Kim, Sea Won;Chong, Sun-A;Moon, Byong Cheun;Lee, Sanghyup;Choi, Jae Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.3
    • /
    • pp.214-218
    • /
    • 2014
  • We introduce a technical equipment of GATe (Green (algae)-tide) water combine developed by K-water. The GATe water combine consists of five modules: main body and buoyant, transfer hopper, screen conveyer, sludge remover, and separator of algae and waste. Also a sprinkler, as the pre-treatment step if necessary, is equipped to the device to spread out environmental-friendly algaecide under the circumstance that the level of algal bloom does not reach to the scum-forming condition. The overall module system of this device is very simple. Based on the field test, the device covers surface area of ca. $500,000m^2day^{-1}$ during the period from May to July, and treats water volume as much as $500,000m^3day^{-1}$ in spite of some variation depending on the water quality condition. The removal efficiency of the device appeared to be over 90%. In addition, the operating duration of the device was able to expand to cover the period between March and November. We expect this new technology can be used to solve algal bloom problems in drinking water resource and public water area.

INDUCTION OF APOPTOSIS IN ORAL CANCER CELL LINE THROUGH AN RECOMBINANT HCCS-1 ADENOVIRUS (재조합 HCCS-1 아데노바이러스를 이용한 구강암 세포주의 세포사멸 유발)

  • Kim, Chang-Hyen;Lee, Dong-Ju;Lee, ll-Kyu;Kim, Myung-Jin;Kim, Jin-Woo;Pyo, Sung-Woon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.4
    • /
    • pp.306-311
    • /
    • 2005
  • Despite advances in surgery, radiotherapy, and chemotherapy, the survival of patients with oral squamous cell carcinoma has not significantly improved over the past several decades. Gene therapy is currently under investigation and shows us new possibility of cancer curing method. This experiment was undergone to find out the cell growth inhibition effect and evidence of apoptosis by HCCS-1(human cervical cancer suppressor-1), one of the candidates of tumor suppressor gene, transducted to human oral cancer cell line. To determine the efficiency of the adenovirus as a gene delivery vector cell line was transducted with LacZ gene and analysed with X-gal staining. Northern blot was performed to confirm the transfection with HSCC-1 gene and cell viability was assessed by cell cytotoxicity assay using cell count kit(CCK). To show the evidence of apoptosis, DNA fragmentation assay and flow cytometry(FACS) were performed. We had successfully construct the recombinant HSCC-1 adenovirus(Ad5CMV-HCCS-1), and importation efficiency was 20% at 2 MOI(multiplicity of infection), 80% at 20 MOI. Northern blot analysis showed that a single 0.6kb mRNA transcript was expressed in Ad5CMV-HCCS-1 transducted cell lines. As a result of CCK, when comparing to control subjects, transducted group showed 50% growth inhibition. In DNA fragmentation assay, according to increasing of MOI, DNA volume was diminished. In FACS analysis, DNA distribution showed fragmentation. This results imply that HCCS-1gene has growth inhibition effect in human oral cancer cell lines through apoptosis induction.

Anaerobic Digestion Efficiency of Remainder from Bacterial Cellulose Production Process using Food Wastes (음식 폐기물을 이용한 박테리아 셀룰로오스 생산 공정 잔류물의 혐기성 소화효율)

  • Jin, Sheng-De;Kim, Seong-Jun
    • KSBB Journal
    • /
    • v.22 no.2
    • /
    • pp.97-101
    • /
    • 2007
  • This study was performed to examine the availability of anaerobic digestion of the remainders caused by bacterial cellulose production process using food wastes. They maybe to be considered as others second pollution sources. Thus, this study was targeted to minimize content of organic material and to obtain more energy in those remnants using two-phase UASB reactor. The working volume of first hydrolysis fermentor was 35 L (total 55 L) and the second methane fermentor was 40 L (total 50 L). The organic loading rate of hydrolysis fermentor was 3 g-VS/L${\cdot}$day and 25,000 ppm of $COD_{cr}$ for methane fermentor. The hydraulic retention time was 18 days for hydrolysis reactor and 33 days for methane reactor. The hydrolysis reactor and methane reactor were performed at 35, 40$^{\circ}C$ respectively. For the efficient stable performance, the composition of organic wastes at each stage was as follow; Food waste with bacterial culture remnants (1 : 1), bacterial cellulose remnants, bacterial cellulose culture remnants with food wastes saccharified solids (1 : 1). When the anaerobic digestion was performed stably at each stage, the COD removal efficiency was 88, 90, 91 % respectively. At this time, methane production rate was 0.26, 0.34, $0.32m^3\;CH_4/kg-COD_{remove}$. As well as the values of anaerobic digestion at third stage were more higher than values of anaerobic digestion using food wastes. It is clearly to say that the food wastes zero-emission system constructed in our lab is more efficient way to treat and reclaim food wastes.

Distributed GIS-Based Watershed Rainfall-Runoff Model Development and Its Calibration using Weather Radar (기상레이더와 지형정보시스템을 이용한 분포형 강우-유출 유역모형의 개발과 검정)

  • Skahill, Brian E.;Choi, Woo-Hee;Kim, Min-Hwan;Kim, Sung-Kyun;Johnson, Lynn E.
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.2
    • /
    • pp.285-300
    • /
    • 2003
  • An event-based, kinematic, infiltration-excess, and distributed rainfall-runoff model using weather radar and Geographic Information System(GIS) was developed to acknowledge and account lot the spatial variability and uncertainty of several parameters relevant to storm surface runoff and surface flow The developed model is compatible with raster GIS and spatially and temporally varied rainfall data. To calibrate the model, Monte Carlo simulation and a likelihood measure are utilized; allowing for a range of possible system responses from the calibrated model. Using rain gauge adjusted radar-rainfall estimates, the developed model was applied and evaluated to a limited number of historical events for the Ralston Creek and Goldsmith Gulch basins within the Denver Urban Drainage and Flood Control District (UDFCD) that contain mixed land use classifications. While based on a limited number of Monte Carlo simulations and considered flood events, Nash and Sutcliffe efficiency score ranges of -0.19∼0.95 / -0.75∼0.81 were obtained from the calibrated models for the Ralston Creek and Goldsmith Gulch basins, based on a comparison of observed and simulated hydrographs. For the Ralston Creek and Goldsmith Gulch basins, Nash and Sutcliffe efficiency scores of 0.88/0.10, 0.14/0.71, and 0.99/0.95 for runoff volume, peak discharge, and time to peak, respectively, were obtained from the model.

Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool (일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가)

  • Park, Hae-Dong;Park, Hyun-Hee;Shin, Jung-Ah;Kim, Tae-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

Development of Naïve-Bayes classification and multiple linear regression model to predict agricultural reservoir storage rate based on weather forecast data (기상예보자료 기반의 농업용저수지 저수율 전망을 위한 나이브 베이즈 분류 및 다중선형 회귀모형 개발)

  • Kim, Jin Uk;Jung, Chung Gil;Lee, Ji Wan;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.10
    • /
    • pp.839-852
    • /
    • 2018
  • The purpose of this study is to predict monthly agricultural reservoir storage by developing weather data-based Multiple Linear Regression Model (MLRM) with precipitation, maximum temperature, minimum temperature, average temperature, and average wind speed. Using Naïve-Bayes classification, total 1,559 nationwide reservoirs were classified into 30 clusters based on geomorphological specification (effective storage volume, irrigation area, watershed area, latitude, longitude and frequency of drought). For each cluster, the monthly MLRM was derived using 13 years (2002~2014) meteorological data by KMA (Korea Meteorological Administration) and reservoir storage rate data by KRC (Korea Rural Community). The MLRM for reservoir storage rate showed the determination coefficient ($R^2$) of 0.76, Nash-Sutcliffe efficiency (NSE) of 0.73, and root mean square error (RMSE) of 8.33% respectively. The MLRM was evaluated for 2 years (2015~2016) using 3 months weather forecast data of GloSea5 (GS5) by KMA. The Reservoir Drought Index (RDI) that was represented by present and normal year reservoir storage rate showed that the ROC (Receiver Operating Characteristics) average hit rate was 0.80 using observed data and 0.73 using GS5 data in the MLRM. Using the results of this study, future reservoir storage rates can be predicted and used as decision-making data on stable future agricultural water supply.

A Study on Energy Efficiency Improvement of LDC Recycling Load Tester (LDC 재생형 부하 시험기의 효율 개선에 관한 연구)

  • Lee, Choon-il;Hong, Yeon-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.86-92
    • /
    • 2016
  • A high-capacity battery installed in a hybrid vehicle or electric vehicle is used to power, or as a power supply for, electric sub-assemblies. In order to use a high-capacity battery as a power supply for electric sub-assemblies, such as an electronic control unit or for lighting, radio, and navigation, there is a need for a DC converter that changes a high voltage of 240-400V to a low voltage of 12-14V, which is done with a low-voltage DC-DC converter (LDC). An LDC undergoes long-term aging so as to reduce latent defects in the production process. With regard to the usual aging method, an LDC is a DC-DC converter. So, a DC power supply is connected and used as input, and a programmable DC electronic load is the output. For stable operation, a product having a larger capacity by 10% (compared to an LDC) is used, and has a structure where electric power is dissipated into 100% heat. So, there is a problem with volume, based on the use of two pieces of equipment to test the LDC, and another problem based on the generation of heat in the programmable DC electronic load. Hence, this paper suggests a load test method as a way of recycling, where a significant portion of the electricity dissipated as heat in a load tester is returned as input. The method realizes savings of 80% or more in the electricity dissipated as heat through improvement in the efficiency of the recycling load tester.