• 제목/요약/키워드: Voltage feedback

검색결과 609건 처리시간 0.024초

극배치에 의한 동기발전기의 전압제어기 설계 (Voltage Controller Design of Synchronous Generator by Pole Assignment)

  • Yim, Han-Suck
    • 대한전기학회논문지
    • /
    • 제34권12호
    • /
    • pp.472-484
    • /
    • 1985
  • A design of robust voltage controller for high speed excitation of synchronous machine was carried out by pole assignment techniques. An affine map from characteristic polynomial coefficients to feedback parameters is formulated in order to place the system eigen values in the desired region. The feedback parameters determined from linearized model are tested on nonlinear model subjecting it to small disturbances and system faults to show the effectiveness of the controller designed by the proposed technique. The results obtained indicate that the controller presented improves the dynamic stability and system performances of conventionally controlled synchronous machine significantly.

  • PDF

Feedback Linearization을 이용한 PSS-AVR 설계 (PSS-AVR Design using Feedback Linearization)

  • 염동희;정정주
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.202-202
    • /
    • 2000
  • In this paper, the synchronous generator model which is derived from the swing equation and the Park's equation is transformed to an adequate form for feedback linearization. And the single controller is designed in order to play the role of both PSS and AVR. The result of the simulations shows that the stability of the system is guaranteed in the wide range of operating points.

여자기와 거버너를 이용한 전력계통 단자전압과 주파수의 비선형제어 (Design of nonlinear controller for voltage and frequency of power system using excitation and governor system)

  • 임선;윤태웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.669-671
    • /
    • 2004
  • This paper presents a MIMO nonlinear controller for the power system consisting of a turbine and a synchronous generator connected to an infinite bus. The controller proposed is based on feedback input-output linearization; its main goal is to regulate the terminal voltage and frequency, and is to improve the transient stability under large disturbances and unexpected faults. It is guaranteed that the voltage converges to its reference value exponentially, and that the frequency and the mechanical/electrical power are bounded. The design procedure is tested on a single machine infinite bus power system through simulations, and is seen to be effective.

  • PDF

새로운 영전압 스위칭 이단방식의 고역률 컨버터 (Novel Two Stage AC-to-DC Converter with Single Switched Zero Voltage Transition Boost Pre-Regulator using DC-Linked Energy Feedback)

  • 노정욱;문건우;정영석;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.385-387
    • /
    • 1996
  • A novel two stage soft-switching ac-to-dc convener with power factor correction is proposed. The proposed convener provides zero-voltage-switching (ZVS) condition to main switch of boost pre-regulator without auxiliary switch. Comparing to the conventional two stage approach(ZVS-PWM boost rectifier followed by off-line ZVS dc-dc step down converter), the proposed approach is simple and reducing EMI noise problem. A new simple DC-linked energy feedback circuit provides zero-voltage-switching condition to boost pre-regulator without imposing additional voltage and current stresses and loss of PWM capability. Operational principle, analysis, control of the proposed converter together with the simulation results of 1KW prototype are presented.

  • PDF

산업현장에서 벡터제어용 유도전동기의 오프라인 파라미터 추정 (Off-line parameter Estimation of Induction Motors for Vector Control in Industrial Field)

  • 권병기;박가우;신원창;조응상;이진섭;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1998
  • Parameter estimation of induction motor for vector control presented in this paper can be easily implemented and applied to inverters in the industrial field, because it needs no additional hardware such as voltage sensor and measuring equipment. At first, the stator resistance including switching loss of inverter is measured by simple voltage-current equation. Next, in pre-magnetization of machine by imposing the d-axis constant field-current, q-axis torque current is forced to the machine until its speed feedback reachs to pre-defined level of speed limit. At this time, we can measure the rotor time-constant by decreasing the distorted output-voltage of inverter. At last, stator inductance, transient inductance, and moment of inertia can be measured by the relationship of output voltage, output torque and speed feedback. The validity and usufulness of this method is verified by experimental results.

  • PDF

Observer-based Voltage Sensorless Control Scheme for an LCL-filtered Grid-connected Inverter

  • Lai, Ngoc Bao;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.266-267
    • /
    • 2017
  • To synchronize the distributed generation (DG) unit with the grid, the voltage sensors are generally employed to obtain the grid phase angle. This paper presents an observer-based voltage sensorless control scheme for a three-phase inverter connected to the grid through an LCL filter. The proposed control scheme consists of an augmented state observer and a feedback controller. The augmented state observer is used to estimate the grid voltages and states of the inverter system, which are then employed to determine the grid voltage angle and to construct the feedback controller. As a result of using the observer, only the grid current sensors are required to accomplish the control scheme. The simulation results are given to prove the validity of the proposed control scheme.

  • PDF

세 개의 부궤환 루프를 가진 저잡음 위상고정루프 (A Low Noise Phase Locked Loop with Three Negative Feedback Loops)

  • 최영식
    • 한국정보전자통신기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.167-172
    • /
    • 2023
  • 본 논문에서는 3개의 부궤환 루프를 가진 저잡음 위상고정루프를 제안하였다. 기존 구조의 위상고정루프는 하나의 부궤환 루프로 구성되어 있어 잡음 특성 개선이 쉽지 않다. 추가된 부궤환 루프는 지터 특성을 결정하는 전압제어발진기의 입력 전압 크기를 줄여주는 역할을 하여 기존 구조로 쉽지 않은 잡음 특성 개선을 가능하게 해준다. 시뮬레이션 결과는 부궤환 루프가 추가될 때마다 지터 특성이 개선되는 것을 보여주고 있다. 전력의 경우 10% 정도 약간 상승하게 되지만, 지터 특성은 2배 정도 개선된다. 제안된 위상고정루프는 1.8V 180nm CMOS 공정을 이용하여 Hspice로 시뮬레이션 하였다.

A Control Strategy Based on Small Signal Model for Three-Phase to Single-Phase Matrix Converters

  • Chen, Si;Ge, Hongjuan;Zhang, Wenbin;Lu, Song
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1456-1467
    • /
    • 2015
  • This paper presents a novel close-loop control scheme based on small signal modeling and weighted composite voltage feedback for a three-phase input and single-phase output Matrix Converter (3-1MC). A small non-polar capacitor is employed as the decoupling unit. The composite voltage weighted by the load voltage and the decoupling unit voltage is used as the feedback value for the voltage controller. Together with the current loop, the dual-loop control is implemented in the 3-1MC. In this paper, the weighted composite voltage expression is derived based on the sinusoidal pulse-width modulation (SPWM) strategy. The switch functions of the 3-1MC are deduced, and the average signal model and small signal model are built. Furthermore, the stability and dynamic performance of the 3-1MC are studied, and simulation and experiment studies are executed. The results show that the control method is effective and feasible. They also show that the design is reasonable and that the operating performance of the 3-1MC is good.

200MW MODULATOR의 출력안정화를 위한 DE-Q'ING SYSTEM에 관한 연구 (Study on the De-Q'ing System for the Output Voltage Stabilization of a 200MW Modulator)

  • 손윤규;오종석;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1612-1614
    • /
    • 1994
  • Modulators Installed in PLS(Pohang Light Source) Linac are composed of a DC high voltage section, a charging section and a discharging section. PFN is charged by a resonant charging mechanism, and discharged by a switching device through the primary of the pulse transformer connected to a load. Charged PFN voltage must be well regulated to obtain stable output pulse voltage at the load. For this purpose, DCHV is controlled by a SCR controller with feedback signal, and PFN voltage is regulated by a De-Q'ing circuit. The full power operation test shows the pulse voltage regulation within ${\pm}0.13%$ with SCR feedback control alone, and within ${\pm}0.08%$ together with De-Q'ing. This paper describes the design concept and operational characteristics of the De-Q'ing circuit.

  • PDF

UPS 용 3상 인버터의 LC필터단 출력전압 제어 방식 비교연구 (A Comparative Study on the Output Voltage Control Strategies of Three Phase Inverter with LC Filter for UPS)

  • 나운기;김태완;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.312-317
    • /
    • 1996
  • This paper compares the output voltage control strategies of three-phase PWM inverter for uninterruptible power supply. The feedforward control, feedforward/feedback control, and decoupled feedback control in both the synchronous reference frame and the stationary reference frame are examined. In particular, it is shown that the response of the decoupled feedback controller in the synchronous reference frame can be improved by pole-zero cancellation method. It is also shown that the pole-zero cancellation method reduces to the deadbeat control, when it is implemented with digital controller.

  • PDF