• 제목/요약/키워드: Voltage Transformer

검색결과 1,683건 처리시간 0.04초

용량성배전변압기에 관한 연구 (A study on capacitive transformer)

  • 이승원
    • 전기의세계
    • /
    • 제18권2호
    • /
    • pp.7-14
    • /
    • 1969
  • From the first customer located right at the substation to the last customer at the end of the line, voltage must be held within close limits, so the voltage regulation is more important than the thermal limit. On a typical distribution system during the peak load period, the voltage drop may be serious enough to cause unsatisfactory operation of home appliances in the residential area, and present many problems to manufacturing industries, where the voltage must be maintained within close limits to insure smooth operation. Among all the factors contributing to voltage drop in the distribution system, the voltage drop in the distribution transformer may account for 30% of this figure. If we can eliminate this factor, the power companies can provide better quality electricity to more customers with the existing distribution facilities, thus saving on initial investment costs. Taking all these problems into consideration, the author undertook the design of a capacitive transformer which would give zero voltage drop at rated load and at 80% lagging power factor while incorporating overload features to withstand 400% overload for at least 100 seconds. The following are the results obtained through design, manufacture and test of an initial experimental transformer built with these specific purposes.

  • PDF

압전 트랜스포머형 액츄에이터를 사용한 고전압 계측 방법에 관한 연구 (A Study on the high voltage measurement method using piezoelectric transformer type-actuator)

  • 이용우;윤광희;류주현;윤현상;김성구;박창엽;정영호;하복남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.177-181
    • /
    • 1998
  • In this paper, we used the $BaTiO_3$ system ceramics with high temperature stability for high voltage devision, and rosen type-piezoelectric transformer for high voltage measurement. when Line-high voltage is 13,20O[V], Input voltage of piezoelectric transformer type-actuator is about 390CV1, and output voltage of it is 26.5FVI on the no-load. And also, temperature stability from >$-25^{\circ}C$ to >$50^{\circ}C$ is less than ${\pm}4.45%$

  • PDF

200 kV 교류 고전압 국가표준 시스템 구축 (Establishment of 200 kV AC High Voltage National Standard System)

  • 정재갑;권성원;이상화;강전홍;송양섭;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1414-1415
    • /
    • 2007
  • 200 kV AC high voltage national standard system has been established with a purpose for support of heavy electrical industry. The system consists of high AC voltage source and regulating unit, the standard voltage transformer, voltage transformer comparator, and voltage transformer burden, and voltage transformer under test.

  • PDF

여자전압의 파형에 따른 Parametric Transformer의 특성 (A Study on the Effects of Exitation Voltage Waveforms on the Performances of Parametric Transformer)

  • 우정인;정기화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.706-709
    • /
    • 1992
  • This paper deals with the operation of a parametric transformer through the normalization of system equations. Based on these equations, the effects of excitation voltage waveforms on the performances of the parametric transformer are analyzed.

  • PDF

과전압에 의한 변압기 철공진 분석 및 방지대책 (Analysis for the Ferroresonance on the Transformer by Overvoltage and Prevention Measures)

  • 윤동현;신동열;차한주
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1543-1550
    • /
    • 2015
  • Ferroresonance is a non-linear vibrational phenomenon that is generated by the electrical interaction of the inductance component with the capacitor component of a certain capacitance as the device of the inductance component such as a transformer is saturated due to the degradation, the waveform distortion of current and voltage, and the oscillation of overcurrent and overvoltage in a system. Recently, ferroresonance was generated from the waveform distortion of current and voltage, or the overvoltage or undervoltage phenomenon caused by the nature of an electrical power system and design technology of the transformer in the three phase transformer system. Hence, in general, ferroresonance analyzed by converting to the LC equivalent circuit. However, in general, the aforementioned analytical method only applies to the resonance phenomenon that is generated by the interaction of the capacitance of bussbar and grounding, and switching as the capacitor component with PT and the transformer as the inductance component in a system. Subsequently, the condition where ferroresonance was generated since overvoltage was supplied as line voltage to the phase voltage and thus the iron core is saturated due to the interconnection between grounded and ungrounded systems could not be analyzed when single phase PT was connected in a ${\Delta}$/Y connection system. In this study, voltage swell in the configuration of grounded circuit of a step-up transformer with the ${\Delta}-{\Delta}$ connection linked to PT for control power and the ferroresonance generated by overvoltage when the line voltage of the ${\Delta}-{\Delta}$ connection was connected to the phase voltage of the grounded Y-Y connection were analyzed using PSCAD / EMTDC through the failure case of the transformer caused by ferroresonance in the system with the ${\Delta}-{\Delta}$/Y-Y connection, and subsequently, the preventive measure of ferroresonance was proposed.

변압기 기반 3상 전압변동발생기의 전압강하 특성해석 (Analysis of Voltage Drop Characteristics of Transformer-based 3-phase Voltage Disturbance Generator)

  • 한흥수;이영호;송웅협;노의철;김인동;김흥근;전태원
    • 전력전자학회논문지
    • /
    • 제15권5호
    • /
    • pp.411-416
    • /
    • 2010
  • 본 논문에서는 변압기 기반 전압변동 발생기의 직렬변압기에 의한 전압강하 특성을 분석하였다. 전압변동 발생기의 회로구성 방식에는 여러 가지가 있으나 본 논문에서는 비교적 비용이 저렴하고 신뢰도가 높은 직렬변압기를 사용한 방식에 대해 다루고자 한다. 직렬변압기에 의한 전압강하는 변압기의 %Z와 부하용량 및 부하역률에 의해 결정된다. 직렬변압기의 설계가 잘못되면 전압강하가 심각하게 발생하여 제대로 된 성능을 확보할 수 없다. 본 논문에서는 10kVA급 전압변동 발생기에 대해 %Z가 4%인 직렬변압기를 사용한 경우 부하역률에 따른 전압강하를 분석하였으며 지상 부하일수록 전압강하가 증가하고 역률이 0.85 지상인 경우 전압강하가 4% 발생함을 시뮬레이션 및 실험을 통하여 확인하였다.

A Study on Novel Power Supply for Microwave Oven Using HVC Embedded High Frequency Transformer

  • Cho Jun-Seok;Park Kang-Hee;Jeong Byung-Hwan;Mok Hyung-Soo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.581-585
    • /
    • 2001
  • This paper describes novel high voltage capacitor(HVC) embedded high frequency transformer and novel inverter power supply topology for driving magnetron in microwave oven. This transformer is used to achieve down­sizing, low-cost and efficiency improvement. Proposed transformer has HVC in its secondary winding. Therefore, this transformer does not need external high voltage capacitor which used in conventional power supply. As use of this transformer, output voltage is shifted from ground to above 2000[V] and efficiency of microwave oven can be improved. The weight of proposed transformer is about one sixth of conventional one and efficiency is improved by seven percent compared to the efficiency of the conventional system.

  • PDF

절연형 풀브리지 DC-DC 컨버터에서의 변압기 포화에 관한 연구 (Study on Transformer Saturation in Isolated Full-Bridge DC-DC Converters)

  • 김정훈;차헌녕
    • 전력전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.261-268
    • /
    • 2020
  • Transformer saturation in full bridge (FB) isolated DC-DC converters is caused by uneven switching speeds and voltage drops in semiconductor devices and mismatched gate signals. In order to prevent transformer saturation, most popular and widely used approach is to insert a capacitor in series with the transformer windings. This study conducts extensive analyses on transformer saturation and the effect of DC blocking capacitors when they are placed in the primary or secondary windings of a transformer. The effect of the DC blocking capacitors is verified in voltage-fed and current-fed FB converters.

철심 코어형 전자식 전압 변성기 개발 (Development of the iron-cored electronic voltage transformer)

  • 강용철;박종민;장성일;김연희;최정환;김용균;송인준;안용호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.138-139
    • /
    • 2008
  • An iron-cored voltage transformer(VT) is usually used to obtain the standard low voltage signal for protection and measurement. Generally, the iron-cored transformers have errors due to the hysteresis characteristics of the iron-core. An error compensating algorithm for iron-cored instrument transformer can improve the accuracy of conventional voltage transformers. This paper describes the iron-cored electronic voltage transformer having the error compensating algorithm. The innovative product composes an iron-cored VT and an intelligent electronic device(IED) having the error compensating algorithm. The test results of the iron-cored electronic voltage transformers in Korea Electro-technology Research Institute(KERI) are presented.

  • PDF

식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구 (A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer)

  • 정중일;허창수
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.