The most appropriate starling method for induction moter (수도사업장 펌프모터(유도전동기)의 합리적 기동방법 시행을 위한 현장 실험)

  • Kim, Gi-Tae;Lee, Eun-Woong;Lee, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.33-34
    • /
    • 2006
  • When high-voltage motors are started, inrush current is rising as a serious power quality problem in terms of electric power line. So, this study is measured electrical data from induction motor's various starting method and is proposed the most appropriate starting method for induction motor at WTPs.

  • PDF

Bipolar Integrated Optical Link Receiver with Low Supply Voltage (바이폴라 집적된 저전압구동 광연결 수신기)

  • 장지근;이상열
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.9-14
    • /
    • 2003
  • The new optical link receiver with data transfer rate higher than 10Mbps at the supply voltage of 1.8V was designed and fabricated using bipolar technology. The fabricated IC showed the dissipation current of 4.6mA under high level input voltage of 1.5V. The high level output voltage($V_{OH}$) and the low level output voltage($V_{OL}$) were 1.15V and 0V, respectively, for a given 10 Mbps signal which has duty ratio of 50%, $V_{IL}$(low level input voltage) of 0.5V, and $V_{IH}$(high level input voltage) of 1.5V, The duty ratio of output waveform was 52.6%. The rising time(t$_{r}$) and the falling time(t$_{f}$) were 9.5ns and 6.8ns, respectively. The propagation delay difference($t_{PHC}-t_{PLH}$) and the jitter($t_j$) were 11.7ns and 4.3ns, respectively.y.

  • PDF

Implementation of Speed Limitation Controller Considering Motor Parameter Variation in High Speed Operation (모터 파라미터 산포를 고려한 고속 운전에서의 속도제한 제어기 구현)

  • Kim, Kyung-Hoon;Yun, Chul;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1584-1590
    • /
    • 2017
  • This paper presents a implementation method of reliable speed limitation controller considering motor parameter variation in high speed operation. In spinning process of drum washing machine, speed increase has to be limited when unallowable imbalance mass is detected. Otherwise, severe noise and vibration can happen because noise and vibration are proportional to imbalance mass. To detect imbalance mass, d-axis current magnitude is used. However, we have to compensate for back-emf and power supply variation by means of detecting them because d-axis current is affected by both of them. On the other hand, we have to carefully estimate back-emf because back-emf is affected by stator resistance variation and inverter voltage error. Stator resistance variation can happen by manufacturing process for mass production or temperature variation in running. And there are inverter voltage errors between command voltage from micro-computer to inverter and real voltage from inverter to motor because of rising and falling time delay and turn-on resistance of power semiconductor switch. To solve this problem, we propose 2-step align current injection method which is to inject step-wise current right before starting. By this method, we can simply obtain stator resistance by ratio of voltage without inverter voltage error and current, and we can measure inverter voltage error. So we can obtain more exact model current, and then by simple calculation with compensation gain, we can estimate more accurate motor back-emf. We show that this method works well. It is verified through experiments.

A Study on the Characteristics of the Electric Field and Electromagnetic Loss according to Bus Bar Size for a cost-effective 24kV High Voltage Switchgear (비용 효율이 높은 24kV급 고압배전반 개발을 위한 Bus Bar 사이즈에 따른 전·자기 손실 특성 분석)

  • Hong, Jonggi;Heo, Jeong Il;Nam, Seokho;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.220-224
    • /
    • 2012
  • The analysis on the bus bar effect is conducted to develop a cost effective 24kV/2,000A switchgear. The temperature enclosures and bus bars could rise due to several heat sources such as eddy current losses and copper losses. Therefore, a study on the characteristics of the electric field intensity and electromagnetic loss according to the bus bar size in a bus bar compartment is essential to design a electrically reliable high voltage switchgear. It is investigated that the electromagnetic influence to the temperature rising and the dielectric stability according to various bus bar sizes by using finite element method(FEM). The electric field intensity and electromagnetic loss according to various bus bar sizes are calculated to design a reliable and a high voltage switchgear. As results, it is found that the electromagnetic loss and the dielectric stability of bus bar could be determined by a bus bar size. It means that a cost effective 24kV/2,000A high voltage switchgear could be developed by selecting the proper size of a bus bar. Also, it is recognized that the electromagnetic characteristics according to various bus bar sizes in order to design an electrically stable high voltage switchgear when the enclosure size is determined as a fixed value. Futhermore, studies on the various nominal voltage class and bus bar sizes will be conducted to develop a cost effective high voltage switchgear.

A Study of the Mitigating Effect Comparison of Voltage Sags by WTG Types Based on the Concept of Area of Vulnerability (타입별 풍력 발전기 설치에 따른 민감 부하의 순간전압강하 저감 효과 비교 분석 연구)

  • Park, Se-Jun;Yoon, Min-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1682-1688
    • /
    • 2017
  • In modern society, the number of industrial customers using equipment sensitive particularly to voltage sags is rapidly increasing. As voltage sags can cause loss of information as well as false operation of the control device, it results in the vast economic damage in industrial processes. One way to mitigate voltage sags in the sensitive loads is the installation of distributed generation (DGs) on the periphery of these loads. In addition, renewable energy sources are currently in the spot light as the potential solution for the energy crisis and environmental issues. In particular, wind power generation which is connected to a grid is rising rapidly because it is energy efficient and also economically feasible compared to other renewable energy sources. On the basis of the above information, in this paper, with Wind Turbine Generators (WTGs) installed nearby the sensitive load, the analysis of the mitigating effect comparison by types of WTGs is performed using voltage sag assessment on the IEEE-30 bus test system. That is, the areas of vulnerability according to types of WTGs are expected to be different by how much reactive power is produced or consumed as WTG reactive power capability is related to the types of WTGs. Using the concept of 'Vulnerable area' with the failure rate for buses and lines, the annual number of voltage sags at the sensitive load with the installation of WTGs per type is studied. This research will be anticipated to be useful data when determining the interconnection of wind power generation in the power system with the consideration of voltage sags.

광 경화성 단분자를 이용한 수직 배향 액정 표시 소자의 노광 조건에 따른 표면 안정화의 연구

  • Kim, Hye-Yeong;Kim, Dae-Hyeon;Gwon, Dong-Won;Kim, U-Il;Jo, In-Yeong;Kim, Seong-Min;Lee, Seung-Hui;Jeong, Yeon-Hak;Ryu, Jae-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.187-187
    • /
    • 2009
  • The PVA(patterned vertical alignment) mode has a excellent dark state at normal direction. but they has a disclination area at divided domain region at voltage on state. so this disclination make a slow response time and decrease transmittance. To overcome this problem, we research about polymer stabilized vertical alignment (PS-VA) method which was using the UV curable reactive mesogen. According to our research, UV exposure condition which was UV dosage condition effected to rising time and decay time and also threshold voltage.

  • PDF

LED Driver Design with Power Optimum Control Function (전력 최적제어 기능을 가진 LED 드라이버 설계)

  • Lee, Seung-Woo;Shin, Hong-Gyu;Cho, Seong-Ik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.253-256
    • /
    • 2011
  • LEDs have small size, long lifespan, high reliability, low power consumption and high color efficiency. Using such a characteristics, LED Back Light Unit has been studying actively. This paper proposes LED driver to minimize power consumption due to LED forward voltage($V_F$) difference and temperature rising. Compared to conventional LED driver, the proposed driver have excellent stability, brief structure and linear output voltage of DC-DC boost converter. Proposed LED Driver circuit was designed using 0.35um CMOS technology. And its operation was verified through simulation.

An Improved Method for Mesh Grounding System Using Unequally Spaced Arrangement (접지도체의 간격배치에 따른 개선된 접지설비 모델)

  • Choi, Hong-Kyoo;Song, Young-Joo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.259-265
    • /
    • 2004
  • No matter how well the equally spaced grounding grid is designed, there are questions keep rising, such as leakage of current from comer conductor, high voltage of touch voltage in corners of grid than in center, and high material cost for grounding grid. The best-fitted design for unequally spaced grounding grid is a part that must be considered. Explain advantages of unequally spaced grounding grid and lead formula by dividing the number of grid division, j, into 20, instead of 7. Then present $D_{ij}$, which is optimum rate for unequally spaced grounding grid and verify safety and economy of the unequally spaced grounding grid by computer simulation with a poly-nominal function form.

  • PDF

Fast Rise Time High Voltage Pulse Generator Applying The Marx Generator (Marx 펄스발생기를 응용한 소형 고전압 급준 펄스 발생장치)

  • Park, Seung-Lok;Chung, Suk-Hwan;Kim, Jin-Gyu;Moon, Jae-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.72-78
    • /
    • 2001
  • A compact size high voltage pulse generator with nanosecond rise time has been designed and investigated experimentally. The inductance of a pulse generator can be reduced by fixing the Marx generator and pulse forming network components into a single cylindrical unit. As a result, nanosecond rise time about $8{\sim}10[ns]$ and pulse width of several hundred [ns] can be obtained from a modified Marx pulse generator. And parametric studies showed that the rise time of the output pulse was depended little on the change of the load resistance and the charging capacitance while, the pulse width of the output pulse was depended greatly upon the change of the load resistance and the charging capacitance. The theoretical showed the possibility to design the laboratory-size pulse generator very fast rising time and a proper pulse width by minimizing stray inductance and varying resistance and capacitance.

  • PDF

The Study on the Optimal Transmission Efficiency Characteristics of Pulse Energy Using Magnetic Pulse Compressors (가포화 자기스위치 MPC를 적용한 저온 플라즈마의 펄스에너지 전송효율 특성)

  • 이유수;정종한;정현주;김문환;김희제
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.383-387
    • /
    • 2003
  • In this paper, we have studied about optimal transmission efficiency characteristics of pulse energy in a coal plant for removing environmental polluted gas. The electrical efficiency of pulse power systems depends on impedance of the reactor. To obtain high efficiency, we used MPC(Magnetic pulse compressor) as the power switch and tested their characteristics as electrode length of the reactor and charging voltage of capacitor, As results, we obtained a compressed pulse such as pulse voltage of 10㎸, rising time 200ns and pulse width of 500ns. With increasing electrode length, the load impedance was decreased but the electrical efficiency was increased.