• Title/Summary/Keyword: Voltage Detector

Search Result 508, Processing Time 0.028 seconds

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

  • Kim, Kyung-O;Ahn, Woo-Sang;Kwon, Tae-Je;Kim, Soon-Young;Kim, Jong-Kyung;Ha, Jang-Ho
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.567-572
    • /
    • 2011
  • A sensitivity analysis of the methods used to evaluate the transport properties of a CdZnTe detector was performed using two different radiations (${\alpha}$ particle and gamma-ray) emitted from an $^{241}Am$ source. The mobility-lifetime products of the electron-hole pair in a planar CZT detector ($5{\times}5{\times}2\;mm^3$) were determined by fitting the peak position as a function of biased voltage data to the Hecht equation. To verify the accuracy of these products derived from ${\alpha}$ particles and low-energy gamma-rays, an energy spectrum considering the transport property of the CZT detector was simulated through a combination of the deposited energy and the charge collection efficiency at a specific position. It was found that the shaping time of the amplifier module significantly affects the determination of the (${\mu}{\tau}$) products; the ${\alpha}$ particle method was stabilized with an increase in the shaping time and was less sensitive to this change compared to when the gamma-ray method was used. In the case of the simulated energy spectrum with transport properties evaluated by the ${\alpha}$ particle method, the peak position and tail were slightly different from the measured result, whereas the energy spectrum derived from the low-energy gamma-ray was in good agreement with the experimental results. From these results, it was confirmed that low-energy gamma-rays are more useful when seeking to obtain the transport properties of carriers than ${\alpha}$ particles because the methods that use gamma-rays are less influenced by the surface condition of the CZT detector. Furthermore, the analysis system employed in this study, which was configured by a combination of Monte Carlo simulation and the Hecht model, is expected to be highly applicable to the study of the characteristics of CZT detectors.

Development of a Small Animal CT using a Linear Detector Array and Small-Scale Slip Rings

  • An Ung Hwan;Chun In Kon;Lee Sang Chul;Cho Min Hyoung;Lee Soo Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.43-47
    • /
    • 2005
  • We have developed a small bore x-ray CT for small animal imaging with a linear x-ray detector array and small-scale slip rings. The linear x-ray detector array consists of 1024 elements of 400□m×400□m with a gadolinium oxysulfide (GOS) scintillator on top of them. To avoid use of expensive large diameter slip rings for projection data transmission from the X­ray detector to the image reconstruction system, we used the wireless LAN technology. The projection data are temporally stored in the data acquisition system residing on the rotating gantry during the scan and they are transmitted to the image reconstruction system after the scan. With the wireless LAN technology, we only needed to use small-scale slip rings to deliver the AC electric power to the X-ray generator and the power supply on the rotating gantry. The performances of the small animal CT system, such as SNR, contrast, and spatial resolution, have been evaluated through experiments using various phantoms. It has been experimentally found that the SNR is almost linearly proportional to the tube current and tube voltage, and the minimum resolvable contrast is less than 30 CT numbers at 40kVp/3.0㎃. The spatial resolution of the small animal CT system has been found to be about 0.9Ip/㎜. Postmortem images of a piglet is also presented.

The fabrication and characterization of a phase change type micro actuator (상 변화방식 마이크로 액츄에이터의 제조 및 성능에 관한 연구)

  • Park, Seung-In;Hwang, Jun-Young;Lee, Sang-Ho;Kang, Kyung-Tae;Kang, Hee-Suk;Kang, Shin-Ill
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1433-1438
    • /
    • 2007
  • Characteristics of a phase change type micro actuator have been studied. The micro actuator has been designed for a micro-pump in an active direct methanol fuel cell(DMFC), consisting of an actuating chamber, a membrane, an electric heater, and a sensor of resistance temperature detector (RTD). In the present study, researches have been focused on the response of the actuator to control algorithm of the heater. The experiments demonstrated that the displacement of the membrane increase with temperature variation which is a function of applied voltage, duty ratio, and operating frequency of heating. The results also showed that operation of the actuator with high voltage at small duty of heating is more efficient than the same power consumption of heating with low voltage at large duty.

  • PDF

Primary side control of Flyback converter using sawtooth wave (톱니파를 이용한 플라이백 컨버터의 일차 측 제어)

  • Nam, Sang-Guk;Kim, Ki-Hyun;Kim, Min-Sung;Seo, Kil-Soo;Kim, Nam-Kyun;Song, Han-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.932-933
    • /
    • 2015
  • This paper presents methods to achieve and control accurate output voltage. PSR removed secondary output voltage sensing circuit, therefore standby power loss can be decreased. When sensing the auxiliary winding voltage, sensing must be done at accurate branch which has $V_O$ information. For this reason this paper presents the PSR sensing technique using sawtooth wave and peak detector. Circuit verification carried out with Spectre in Cadence corporation and Manga/Hynix $0.35{\mu}m$ 700V process.

  • PDF

CORRECTION OF GAS MULTIPLICATION UNIFORMITY OF X-RAY DETECTOR BY VOLTAGE COMPANSATION METHOD (전압 보상법에의한 X-선 검출기의 이득 보정)

  • 남욱원;최철성;문신행
    • Journal of Astronomy and Space Sciences
    • /
    • v.10 no.1
    • /
    • pp.86-93
    • /
    • 1993
  • We experiment of the method to obtain the uniform gas multiplication in multiwire proportional counter. The general techenique of anode wire connection for the high voltage supply could not secure the uniformity of multiplication because of the edge effect at the outer anode wires. We found that the variation of the multiplication could be corrected in the accuracy of $\pm$1.6% rms using the voltage compansation method.

  • PDF

Analysis of Insulation Aging in Operating High Voltage Motors (운전중인 고압전동기에서 절연열화 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

A Study on Micom Algorithm Design for Prevention of Serial Parallel Arc Accident (직병렬아크사고 예방을 위한 마이컴 알고리즘 설계에 관한 연구)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl;Choi, Shin-Hyeong;Jung, Do-Young;Kim, Dae-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.9-11
    • /
    • 2018
  • This paper studies on the development of an electric fire prevention system with the detection and alarm in case of parallel arc fault occurrence in low voltage distribution lines. The proposed detector has the characteristics of high speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. The line voltage is always feedback, and when an arc or a spark occurs, these are detected by the microcomputer. In addition, we design and develop algorithms using high speed and high precision microcomputer. A new conceptual control technique is adopted that RCD cuts-off by forming a forced short circuit between the phase voltage and ground in the event of an electrical accident. Some experimental tests of the proposed system also confirm practicality and the validity of the analytical results.

  • PDF

A Design of LLC Resonant Controller IC in 0.35 um 2P3M BCD Process (0.35 um 2P3M BCD 공정을 이용한 LLC 공진 제어 IC 설계)

  • Cho, Hoo-Hyun;Hong, Seong-Wha;Han, Dae-Hoon;Cheon, Jeong-In;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.5
    • /
    • pp.71-79
    • /
    • 2010
  • This paper presents a design of a LLC resonant controller IC. LLC resonant controller IC controls the voltage of the 2nd side by adjusting frequency the input frequency of the external resonant circuit. The clock generator is integrated to provide the pulse to the resonant circuit and its frequency is controlled by the external resistor. Also, the frequency of the VCO is adjusted by the feedback voltage. The protection circuits such as UVLO(Under Voltage Lock Out), brown out, fault detector are implemented for the reliable and stable operation. The HVG, and LVG drivers can provide the high current and voltage to the IGBT. The designed LLC resonant controller IC is fabricated with the 0.35 um 2P3M BCD process. The overall die size is $1400um{\times}1450um$, and supply voltage is 5V, 15V.

Study on the Plasma Oscillation for Gas Chromatographic detector (플라즈마진동을 이용한 기체크로마토그래프의 검출기에 대한 연구)

  • Kim, Hyo Jin;Mang, Dae Young;Kang, Jong Seong
    • Analytical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.369-374
    • /
    • 1993
  • Plasma oscillation has been observed during the development of the glow discharge as detector for gas chromatography. The variation of oscillation frequency shows the better stability and detection limits than the changes in the dischange curent. To investigate the range of useful operating conditions and to gain insight into the mechanism, the effect of experimental parameters on plasma oscillation have been studied. This study includes the variation of discharge current, pressure and discharge gap. Frequency ranges of 10KHz to 10MHz have been observed with the various shapes of oscillation. Two kinds of mode for oscillation are observed with the variation of electrode gap at low pressure and low voltage.

  • PDF

In-orbit performance prediction for Amon-Ra energy channel instrument

  • Seong, Se-Hyun;Hong, Jin-Suk;Ryu, Dong-Ok;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.30.2-30.2
    • /
    • 2011
  • In this report, we present in-orbit radiometric performance prediction for the Amon-Ra (Albedo Monitor and Radiometer) energy channel instrument. The Integrated Ray Tracing (IRT) computational technique uses the ray sets arriving at the Amon-Ra instrument aperture orbiting around the L1 halo orbit. Using this, the variation of flux arriving at the energy channel detector was obtained when the Amon-Ra instrument including the energy channel design observes the Sun and Earth alternately. The flux detectability was verified at the energy channel detector (LME-500-A, InfraTecTM). The detector time response and RMS signal voltage were then derived from the simulated flux variation results. The computation results demonstrate that the designed energy channel optical system satisfies the in-orbit detectability requirement. The technical details of energy channel instrument design, IRT model construction, radiative transfer simulation and output signal computation results are presented together with future development plan.

  • PDF