• Title/Summary/Keyword: Voltage Change

Search Result 1,833, Processing Time 0.034 seconds

Analytical Model of Threshold Voltage for Negative Capacitance Junctionless Double Gate MOSFET Using Ferroelectric (강유전체를 이용한 음의 정전용량 무접합 이중 게이트 MOSFET의 문턱전압 모델)

  • Hakkee Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.2
    • /
    • pp.129-135
    • /
    • 2023
  • An analytical threshold voltage model is presented to observe the change in threshold voltage shift ΔVth of a junctionless double gate MOSFET using ferroelectric-metal-SiO2 as a gate oxide film. The negative capacitance transistors using ferroelectric have the characteristics of increasing on-current and lowering off-current. The change in the threshold voltage of the transistor affects the power dissipation. Therefore, the change in the threshold voltage as a function of theferroelectric thickness is analyzed. The presented threshold voltage model is in a good agreement with the results of TCAD. As a results of our analysis using this analytical threshold voltage model, the change in the threshold voltage with respect to the change in the ferroelectric thickness showed that the threshold voltage increased with the increase of the absolute value of charges in the employed ferroelectric. This suggests that it is possible to obtain an optimum ferroelectric thickness at which the threshold voltage shift becomes 0 V by the voltage across the ferroelectric even when the channel length is reduced. It was also found that the ferroelectric thickness increased as the silicon thickness increased when the channel length was less than 30 nm, but the ferroelectric thickness decreased as the silicon thickness increased when the channel length was 30 nm or more in order to satisfy ΔVth=0.

DC-Link Voltage Unbalance Compensation of Reactive Power Compensator using Multi-level Inverter (멀티레벨 인버터를 이용한 무효전력 보상장치에서의 DC-Link 전압 불평형 보상)

  • Kim, Hyo-Jin;Jung, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.422-428
    • /
    • 2013
  • Recently, we use a static synchronous compensator(STATCOM) with cascaded H-bride topologies, because it is easy to increase capacity and to reduce total harmonic distortion(THD). When we use equipment for reactive power compensation, dc-link voltage unbalances occur from several reasons although loads are balanced. In the past, switching pattern change of single phase inverter and reference voltage magnitude change of inverter equipped with power sensor have been used for dc-link voltage balance. But previous methods are more complicated and expensive because of additional component costs. Therefore, this paper explains reasons of dc-link voltage unbalance and proposes solution. This solution is complex method that is composed of reference voltage magnitude change of inverter without additional hardware and shifted phase angle of inverter reference voltages change. It proves possibility through 1000[KVA] system simulation.

Multi-level UnderVoltage Load Shedding Scheme Considering Rate of Change of Voltage for Voltage Stability (전압 변동률을 고려한 수도권 전압 안정화 다단계 부하차단 적용 방안)

  • Lee, Yun-Hwan;Kim, Tae-Gyun;Kim, Ji-Hun;Lee, Byong-Jun;Kang, Bu-Il;Cho, Jong-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2335-2341
    • /
    • 2009
  • High technique growth of modem times and high industrial facility in consequence of buildings demand for electric power of an extensive scale with stability supply and maintenance of high quality. But, power system always have risk of network contingency. When power system break out disturbance, it circumstantially happen like uncontrolled loss of load developing from of cascading. Severely which would be raised wide area blackout, plan to prevent, which make stability through a little of load shedding and multi-level UnderVoltageLoadShdding should work. This paper presents target, sensitivity of bus voltage have choose appropriating load shedding location and load shedding decision making logic with considering rate of change of voltage have studied multi-level under voltage load shedding scheme. Calculation of rate of change of voltage applied method of least square. As a result, we are studied an dynamic analysis of 2008 summer peak data. We have been known that network analysis is a little development and developing UnderVoltageLoadShedding scheme.

Study on the Electrical Characteristics of 600 V Trench Gate IGBT with Single N+ Emitter (600 V급 IGBT Single N+ Emitter Trench Gate 구조에 따른 전기적 특성)

  • Shin, Myeong Cheol;Yuek, Jinkeoung;Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.5
    • /
    • pp.366-370
    • /
    • 2019
  • In this paper, a single N+ emitter trench gate-type insulated gate bipolar transistor (IGBT) device was studied using T-CAD, in order to achieve a low on-state voltage drop (Vce-sat) and high breakdown voltage, which would reduce power loss and device reliability. Using the simulation, the threshold voltage, breakdown voltage, and on-state voltage drop were studied as a function of the temperature, the length of time in the diffusion process (drive-in) after implant, and the trench gate depth. During the drive-in process, a $20^{\circ}C$ change in temperature from 1,000 to $1,160^{\circ}C$ over a 150 minute time frame resulted in a 1 to 4 V change in the threshold voltage and a 24 to 2.6 V change in the on-state voltage drop. As a result, a 0.5 um change in the trench depth of 3.5 to 7.5 um resulted in the breakdown voltage decreasing from 802 to 692 V.

The study on the thickness change of tantalum oxide as voltage drop in electrolyte

  • Hur, Chang-Wu;Lee, Kyu-Chung
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.4
    • /
    • pp.453-456
    • /
    • 2010
  • Tantalum oxide ($Ta_2O_5$) films are of considerable interest for a range of application, including optical waveguide devices, high temperature resistors, and oxygen sensors. In this paper, we establish an anode oxidation process of tantalum thin film. The voltage drop in the electrolyte is affected not in voltage change but in current change. If the voltage drop in the electrolyte is same with cathode oxidation voltage, the current changes logarithmically in proportion to the voltage drop in interface of tantalum oxide and electrolyte. As a result of the measurement on the electrical property of tantalum oxide thin film, when the thickness of the insulator film is $1500{\AA}$, the breakdown voltage is 350volts and dielectric constant is 29.

Analysis for Evaluating the Impact of PEVs on New-Town Distribution System in Korea

  • Choi, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.859-864
    • /
    • 2015
  • This paper analyzes the impact of Plug-in Electric vehicles(PEVs) on power demand and voltage change when PEVs are connected to the domestic distribution system. Specifically, it assesses PEVs charging load by charging method in accordance with PEVs penetration scenarios, its percentage of total load, and voltage range under load conditions. Concretely, we develop EMTDC modelling to perform a voltage distribution analysis when the PEVs charging system by their charging scenario was connected to the distribution system under the load condition. Furthermore we present evaluation algorithm to determine whether it is possible to adjust it such that it is in the allowed range by applying ULTC when the voltage change rate by PEVs charging scenario exceed its allowed range. Also, detailed analysis of the impact of PEVs on power distribution system was carried out by calculating existing electric power load and additional PEVs charge load by each scenario on new-town in Korea to estimate total load increases, and also by interpreting the subsequent voltage range for system circuits and demonstrating conditions for countermeasures. It was concluded that total loads including PEVs charging load on new-town distribution system in Korea by PEVs penetration scenario increase significantly, and the voltage range when considering ULTC, is allowable in terms of voltage tolerance range up to a PEVs penetration of 20% by scenario. Finally, we propose the charging capacity of PEVs that can delay the reinforcement of power distribution system while satisfying the permitted voltage change rate conditions when PEVs charging load is connected to the power distribution system by their charging penetration scenario.

Dynamic Response Improvement of Stand Alone Engine-Generator System using Double Voltage Detection Method (전압 이중 검출법에 의한 독립형 엔진-발전기 시스템 응답특성 개선)

  • Lee, Dong-Hee;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1195-1199
    • /
    • 2008
  • In this paper, peak detector of generator's output voltage and variable gain controller are introduced for a fast dynamic response. The conventional r,m.s, signal detected has inherent time delay, and the dynamic response of generator using conventional PID controller has some problem in sudden load change. In this paper, the peak detector and signal selector with variable gain controller is used to overcome this problem. The main controller can check the voltage state from the peak detector. When a sudden load change, the over-voltage and under-voltage signal from peak detector change the controller's gain and exciter's current reference. The proposed scheme can improve the dynamic response, which is verified from experimental test of 200kW diesel engine-generator.

Development Pole Transformer with Automatic Tap Changer (자동 탭 절환 내장형 주상변압기 개발에 관한 연구)

  • Nam-Koong, Won;Lee, Sung-Woo;Jang, Moon-Jong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.108-113
    • /
    • 2013
  • Change of supply voltage, customer load, output of distributed generation, etc cause voltage change in distribution system. OLTC and SVR are usually used to supply normal voltage at customer. But usage of these devices is inefficient and uneconomical in certain circumstances. To solve this problem, new pole transformer which has automatic tap changer is developed. The transformer changes tap when voltage changes. And it has latch switch and reactor for supplying power without outage. To verify normal operation of tap changer, test is conducted. SVR and 50kVA load is used for test.

Impedance Characteristics of Blue Fluorescent OLED According to Elapsed Time (경과 시간에 따른 청색 형광 OLED의 Impedance 특성)

  • Kong, Do-Hoon;Yang, Jae-Woong;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.5
    • /
    • pp.405-410
    • /
    • 2017
  • In order to study current-voltage-luminance and impedance characteristics according to elapsed time, a blue fluorescent OLED was fabricated. The current density and luminance gradually decreased in accordance with elapsed time and did not emit light after 480 hours, and the threshold voltage increased as time elapsed. The Cole-Cole plot was a semicircular shape of a very large size at 2 V of the applied voltage below the threshold voltage, and the maximum value of the real number impedance did not change greatly from 9314.5 to $9902.2{\Omega}$ as time elapsed. Applied voltages 4, 6, and 8 V above the threshold voltage showed a large change in the real number impedance value at the semicircle end to 9,678.2, 9,826, $9,535.4{\Omega}$ according to the elapsed time from 2,222.5, 183.7, $48.2{\Omega}$ immediately after fabricating the device. By increasing the applied voltage beyond the threshold voltage just after device fabrication, the energy difference between the device and the organic layer was overcome and the current flowed, the maximum value of the real number impedance sharply decreased. As time passed, current did not flow through the element even at high applied voltage due to degradation of the element, and even when the applied voltage was higher than the threshold voltage, it showed an impedance value such as applied voltage equal to or less than the threshold voltage. As a result, it can be learned that the change in the impedance with elapsed time reflects the characteristics due to the degradation of the OLED and can predict the characteristics and lifetime of the OLED.

Effects of Advertising according to the Altering Color Coordinates of the Outdoor Billboards a Inorganic Powder EL Lamp That was made by Screen Printing Technique (스크린 인쇄 기법에 의해 제작된 옥외 광고용 분산형 무기 EL 램프의 색좌표 변화와 광고 효과)

  • Moon, Kil-Hwan;Lee, Kwang-Sook
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.30 no.1
    • /
    • pp.47-58
    • /
    • 2012
  • The inorganic powder EL lamp was made by screen printing technique with a phosphor ink and a dielectric ink. Value of color coordinates X and Y increased under the condition of supplying driving power to the inorganic powder EL lamp and changing voltage with constant frequency. When frequency was changed under the constant voltage, value of color coordinates X and Y were decreased with increasing frequency. However, level of change of color coordinates X was different from color coordinates Y. When voltage was increased under constant frequency, changing degree of color coordinates X and Y shows similarity. But under the constant voltage with changing frequency, color coordinates X and Y were differently changed that degree of change of color coordinates Y showed five times more than that of color coordinates X. As increasing thickness of phosphor ink and dielectric ink, level of voltage and frequency, color coordinates X and Y were slightly changed. According to the thickness of phosphor ink and dielectric ink, and level of voltage and frequency, color coordinate of color light was changed. Frequency was most important element influencing on the change of color coordinate.