• Title/Summary/Keyword: Vision correction

Search Result 208, Processing Time 0.025 seconds

The Awareness Survey of Vision Correction Surgery Side Effect (시력교정술 부작용 인지도 조사)

  • Lee, Jeung-Young;Seo, Jung-Ick;Park, Eun-Kyoo
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.737-741
    • /
    • 2016
  • Purpose. To investigate awareness of vision correction surgery side effects and investigated side effects affect vision correction surgery decisions. Methods. This study was performed on 85 college students. The awareness of vision correction surgery, the awareness of vision correction surgery side effects, and investigated side effects affect surgery decisions. Results. 37.6 % (32 people) replied that the drying effects is representative side effects of the eye correction surgery. 68.2% (58 people) answered the reason of eye surgery is uncomfortable wearing glasses. 74.1%(63 people) answered the side effects does not affect vision correction surgery decision. Prior to hear a description of side effects, 31.8% percent people hope the surgery. after listening to explain of side effects, only 10.6% percent people hope the surgery. Conclusions. People who want to get vision correction surgery should check their vision condition through prior examination and consultation. What side effects in the operation should be reviewed. That is the only way to reduce side effects.

Comparison between Accommodative Response Change on the Full Vision Correction and Low Vision Correction (완전교정과 저교정 상태에서 조절반응 변화량의 비교)

  • Bae, Sung-Hyun;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • Purpose: The study tried to figure out accommodative changes by measuring accommodative response, appearing on the full vision correction and low vision correction, with both eyes open-view auto-refractometer (Nvision-K5001, Shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 79 college students (58 males and 21 females) aged between 20 and 30($21.14{\pm}2.00$), by measuring accommodative changes with fixation distance at 1.0 m for eyesight of 1.0 after full version correction. The distances of 5.0 m, 1.0 m, 0.50 m, 0.33 m and 0.25 m for eyesight of 0.8, 0.7 and 0.6 after low vision correction arbitrarily added plus lens were applied. Results: the shorter measure fixation distances were, the greater changes accommodative response showed a tendency in the state of both full vision correction and low vision correction(0.7). The state of full vision correction showed a greater change of accommodative response than that of low vision correction(0.7). Both right and left eyes showed low accommodative responses in the state of low vision correction(0.7) than that of full vision correction. As a result of analyzing accommodative response at an eyesight of 0.8, 0.7, and 0.6 after low vision correction, the poorer eyesight was the lower accommodative response. Conclusions: Low vision correction from a near distance is expected to avoid unnecessary accommodative response, make eyes relaxed and prevent accommodative function disorder.

Optimal design of water distribution system using modified hybrid vision correction algorithm (Modified hybrid vision correction algorithm을 활용한 상수관망 최적설계)

  • Ryu, Yong Min;Lee, Eui Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1271-1282
    • /
    • 2022
  • The optimal design of Water Distribution System (WDS) is used in various ways according to the purpose set by the user. The optimal design of WDS has various purposes, such as minimizing costs and minimizing energy generated when manufacturing pipes. In this study, based on the Modified Hybrid Vision Correction Algorithm (MHVCA), a cost-optimal design was conducted for various WDSs. We also propose a new evaluation index, Best Rate (BR). BR is an evaluation index developed based on the K-mean Clustering Algorithm. Through BR, a comparison was made on the possibility of searching for the optimal design of each algorithm used in the optimal design of WDS. The results of MHVCA for WDS were compared with Vision Correction Algorithm (VCA) and Hybrid Vision Correction Algorithm (HVCA). MHVCA showed a lower cost design than VCA and HVCA. In addition, MHVCA showed better probability of lower cost designs than VCA and HVCA. MHVCA will be able to show good results when applied to the optimal design of WDS for various purposes as well as the optimal design of WDS for cost minimization applied in this study.

A Case Study of the Effects of Vision Therapy on a Recurrent Intermittent Exotropia Patient Before and After Surgical Correction (간헐성외사시의 수술 전과 수술 후 재발 환자의 비젼세라피 효과 증례)

  • Lee, Chang-Seon;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.127-131
    • /
    • 2009
  • Purpose: The purpose of this case study is to study effect of the vision therapy on a recurrent intermittent exotropia patient before and after surgical correction. Methods: The vision therapy observation included both before and after the surgical correction of intermittent exotropia patients who had binocular vision disorder without opthalmic diseases. Results: According to the results, vision therapy method showed improvement, both case before and after the surgical correction of intermittent exotropia patients. Conclusions: Therefore we suggest that vision therapy is an effective and alternative method for intermittent exotropia patients.

  • PDF

Development of the new meta-heuristic optimization algorithm inspired by a vision correction procedure: Vision Correction Algorithm (시력교정 과정에서 착안된 새로운 메타휴리스틱 최적화 알고리즘의 개발: Vision Correction Algorithm)

  • Lee, Eui Hoon;Yoo, Do Guen;Choi, Young Hwan;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.117-126
    • /
    • 2016
  • In this study, a new meta-heuristic optimization algorithm, Vision Correction Algorithm (VCA), designed according to the optical properties of glasses was developed. The VCA is a technique applying optometry and vision correction procedure to optimization algorithm through the process of myopic/hyperopic correction-brightness adjustment-compression enforcement-astigmatism adjustment. The proposed VCA unlike the conventional meta-heuristic algorithm is an automatically adjusting global/local search rate and global search direction based on accumulated optimization results. The proposed algorithm was applied to the representative optimization problem (mathematical and engineering problem) and results of the application are compared with that of the present algorithms.

Development of Self-Adaptive Meta-Heuristic Optimization Algorithm: Self-Adaptive Vision Correction Algorithm (자가 적응형 메타휴리스틱 최적화 알고리즘 개발: Self-Adaptive Vision Correction Algorithm)

  • Lee, Eui Hoon;Lee, Ho Min;Choi, Young Hwan;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.314-321
    • /
    • 2019
  • The Self-Adaptive Vision Correction Algorithm (SAVCA) developed in this study was suggested for improving usability by modifying four parameters (Modulation Transfer Function Rate, Astigmatic Rate, Astigmatic Factor and Compression Factor) except for Division Rate 1 and Division Rate 2 among six parameters in Vision Correction Algorithm (VCA). For verification, SAVCA was applied to two-dimensional mathematical benchmark functions (Six hump camel back / Easton and fenton) and 30-dimensional mathematical benchmark functions (Schwefel / Hyper sphere). It showed superior performance to other algorithms (Harmony Search, Water Cycle Algorithm, VCA, Genetic Algorithms with Floating-point representation, Shuffled Complex Evolution algorithm and Modified Shuffled Complex Evolution). Finally, SAVCA showed the best results in the engineering problem (speed reducer design). SAVCA, which has not been subjected to complicated parameter adjustment procedures, will be applicable in various fields.

Application of modified hybrid vision correction algorithm for an optimal design of water distribution system (상수관망 최적설계를 위한 Modified Hybrid Vision Correction Algorithm의 적용)

  • Ryu, Yong Min;Lee, Eui Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.7
    • /
    • pp.475-484
    • /
    • 2021
  • The optimal design for water distribution system (WDS) is not only satisfying the minimum required water pressure of the nodes, but also minimizing pipe cost, etc. The number of designs of WDS increases exponentially due to the arrangement of various pipes. Various optimization algorithms were applied to propose an optimized design of WDS. In this study, Modified Hybrid Vision Correction Algorithm (MHVCA) with improved self-adapting parameter was applied to optimal design of WDS. The performance was improved by changing the Hybrid Rate (HR) of the existing Hybrid Vision Correction Algorithm (HVCA) to nonlinear HR. To verify the performance of the proposed MHVCA, it applied to mathematical problems consisting of 2 and 30 decision variables and constrained mathematical problems. In order to review the application results of MHVCA, it was compared with Harmony Search (HS), Improved Harmony Search (IHS), Vision Correction Algorithm (VCA) and HVCA. Finally, MHVCA was applied to the optimal design problem of WDS and the results were compared with other algorithms. MHVCA showed better results than other algorithms in mathematical problems and WDS problem. MHVCA will be able to show good results by applying to various water resource engineering problems as well as problems applied in this study.

Improvement of Hybrid Vision Correction Algorithm for Water Resources Engineering Problem (수자원공학 문제 적용을 위한 Hybrid Vision Correction Algorithm의 개량)

  • Ryu, Yong Min;Lee, Eui Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.196-196
    • /
    • 2021
  • 상수관망은 많은 관을 통해 물의 수요가 있는 곳으로 물을 공급해주는 역할을 하는 사회기반 시설물이다. 상수관망 설계의 요점은 두 가지로 구분할 수 있다. 첫 번째 요점은 다양한 종류의 관배치로 인한 상수관망 설계안의 많은 경우의 수이다. 두 번째 요점은 상수관망 내 절점의 최저 요구수압 등의 제약조건이다. 두 가지 요점이 있는 상황에서 상수관망 설계비용의 최소화를 위한 상수관망 최적설계는 많은 계산이 요구된다. 많은 계산이 요구되기 때문에 상수관망 최적설계에 최적화 기법을 적용할 수 있다. 본 연구에서 상수관망 최적설계를 위해 적용된 최적화 기법은 Hybrid Rate(HR)를 개선한 Hybrid Vision Correction Algorithm(HVCA)이다. HVCA는 Vision Correction Algorithm(VCA)을 기반으로 추가적인 전역탐색을 실행하는 Centralized Global Search(CGS)의 적용 및 자가적응형 매개변수인 Hybrid Rate(HR)를 적용하여 사용성과 성능을 개량한 알고리즘이다. HVCA의 기존 HR은 선형적으로 증가하는 형태이다. 선형적으로 증가하는 HR로 인해 HVCA는 최적해 탐색과정에서 지역해에 빠지는 문제가 발생하였다. HVCA의 문제를 해결하기 위해 HR을 비선형적으로 증가하는 형태로 개량하였다. HR이 개량된 HVCA를 수자원공학 문제인 상수관망 최적설계 문제에 적용하여 결과를 비교하였다. 적용결과 HR이 개량된 HVCA가 기존의 HVCA보다 낮은 설계 비용을 나타내었다. 상수관망 최적설계 적용결과를 바탕으로 HR이 개량된 HVCA는 상수관망 최적설계 이외의 수자원공학 문제에도 적용가능할 것이다.

  • PDF

A Study on the Wearing Status of the Near Vision Refractive Error Correction Device for Presbyopia in Each Residential District (Chungcheongnam-do and Gyeonggi-do) (거주지별(충청남도와 경기도) 노안의 근거리 시력교정안경 착용 실태)

  • Kim, Jung-Hee;Lee, Young-Il;Kang, Su-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.103-108
    • /
    • 2009
  • Purpose: The objective of this study is to compare and analyze the wearing status of refractive error correction devices of elders who reside in a city or in a small town district. Methods: Each of opticians from a small town or a city was selected for the study of wearing status of presbyopia correction device for each residential district in units of percentage. with the analysis of the age and gender distributions of the elders, numbers of elderly members, and the kinds of presbyopia correction. Results: The wearing rate of progressive lens was reduced in reverse proportion to the increase of the age for the people of presbyopia in a twon. Pepople in 60s living in a town perferred to wearing bifocal lens, but people of 50~60s preferred to single vision lenses. However, none of people living in a city who is diagnosed as presbyopia had refractive error correction device, and no one used bifical lenses. The progressive lens was mostly used in the people of 40~50s and using rate of those lenses reduced with the age; and single vision lens had the highest rate of in the 40~50s but no one wore it in the 70s. Conclusions: Among the refractive error correction devices, the progressive lens was most widely worn by presbyopia group who is living in a town or a city. In particular, the refractive error correction devices were most preferred in 40~50s of early presbyopia. The highest preference for the progressive lens in the people with the early presbyopia indicates that the wearing rate of the progressive will be increased in future. Therefore, the opportunity of systematic education on the progressive lens should be increased.

  • PDF

Development of Hybrid Vision Correction Algorithm (Hybrid Vision Correction Algorithm의 개발)

  • Ryu, Yong Min;Lee, Eui Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.61-73
    • /
    • 2021
  • Metaheuristic search methods have been developed to solve problems with a range of purpose functions in situations lacking information and time constraints. In this study, the Hybrid Vision Correction Algorithm (HVCA), which enhances the performance of the Vision Correction Algorithm (VCA), was developed. The HVCA has applied two methods to improve the performance of VCA. The first method changes the parameters required by the user for self-adaptive parameters. The second method, the CGS structure of the Exponential Bandwidth Harmony Search With a Centralized Global Search (EBHS-CGS), was added to the HVCA. The HVCA consists of two structures: CGS and VCA. To use the two structures, a method was applied to increase the probability of selecting the structure with the optimal value as it was performed. The optimization problem was applied to determine the performance of the HVCA, and the results were compared with Harmony Search (HS), Improved Harmony Search (IHS), and VCA. The HVCA improved the number of times to find the optimal value during 100 repetitions compared to HS, IHS, and VCA. Moreover, the HVCA reduced the Number of Function Evaluations (NFEs). Therefore, the performance of the HVCA has been improved.