• 제목/요약/키워드: Viscoelastic damper

검색결과 82건 처리시간 0.023초

점성 유체 감쇠기의 크기 변화에 따른 성능 변화 예측 (Prediction of the Ability of a Viscous Fluid Damper with Respect to Change of the Size of the Damper)

  • 박화용;윤종민;유성환;김창열;이재응
    • 한국소음진동공학회논문집
    • /
    • 제22권1호
    • /
    • pp.53-60
    • /
    • 2012
  • To reduce the vibration in industrial settings, the viscous fluid dampers have been widely used. Since the damper shows a viscoelastic behavior, many methods to predict the behavior have been investigated. But the methods did not consider a change of damper size that is important factor for practical design engineer. In this study, to predict a change of damper ability with respect to a change of damper size, the dynamic experiment were conducted with fixed aspect ratio and gap. The damping coefficient at zero frequency was computed through theoretical and experiment approach in order to fit the experimental results using fractional derivative Maxwell model.

압전형 센서/액추에이터를 이용한 진동구조물의 능동-수동제어 (Active-passive control of flexible sturctures using piezoelectric sensor/actuator)

  • 고병식
    • 소음진동
    • /
    • 제5권3호
    • /
    • pp.313-325
    • /
    • 1995
  • Two active/passive vibration dampers were designed to control a cantilever beam first mode of vibration. The active element was a piezoelectric polymer, polyvinlidene fluoride (PVDF). The passive damping was provided by the application of a viscoelastic layer on the surface of the steel beam. Two substantially different damper configurations were designed and tested. One damper consisted of a piezoelectric actuator bonded to one face of the beam, with a viscoelastic layer applied to the other surface of the beam. The second one was composed of a layer viscoeastic layer with one surface bonded to the beam, and with other being constrained by nine piezoelectric actuators connected in parallel. A control law based on the sign of the angular velocity of the cantilever beam was implemented to control the beam first mode of vibration. The piezoelectric sensor output was digitally differentiated to obtain the transverse linear velocity, and its sign was used in the control algorith. Two dampers provided the system a damping increase of a factor of four for the first damper and three for the second damper. Both dampers were found to work well at low levels of vibration, suggesting that they can be used effectively to prevent resonant vibrations in flexible structure from initiating and building up.

  • PDF

점탄성-슬릿 복합댐퍼로 보강된 건물의 내진성능평가 (Seismic Performance Evaluation of Structures Retrofitted with Viscoelastic-Slit Hybrid Dampers)

  • 김민성;자오동쉬;김진구
    • 한국지진공학회논문집
    • /
    • 제22권7호
    • /
    • pp.361-367
    • /
    • 2018
  • This study investigates the seismic performance of a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A moment-framed structure is designed without seismic load and is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis of the structure with and without the dampers. The analysis results show that after seismic retrofit the probability of reaching damage states, especially the complete damage state, of the structure turn out to be significantly reduced.

점탄성 감쇠기가 설치된 철골조 건물의 비탄성 해석 (Inelastic Analysis of Steel Frame Structures with Viscoelastic Damper)

  • 김진구
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.186-193
    • /
    • 2000
  • In this study the effect and applicability of viscoelastic dampers on the seismic reinforcement of steel framed structures are investigated in the context of the performance based design approach. The effect of the damper on dissipating the input seismic energy was investigated with a single degree of freedom system. For analysis models a five-story steel frame subjected to gravity load and a ten-story structure subjected to gravity and wind load were designed. the code-specified design spectrums were constructed for each soil type and performance objective and artificial ground excitation records to be used in the nonlinear time history analysis were generated based on the design spectrums. Interstory drift was adopted as the primary performance criterion. According to the analysis results both model structures turned out to satisfy the life safety performance level for most of the soil conditions except for the soft soil. It was also found that the seismic performance could be greatly enhanced by installing viscoelastic dampers on appropriate locations.

  • PDF

실 구조물 진동제어를 위한 점탄성 댐퍼 설계 및 적용 실험 (Designs and Tests for the Vibration Control of Full-Scale Steel Frame Structure with Added Viscoelastic Dampers)

  • 정정교;김두훈;김영찬;박진일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.687-692
    • /
    • 2002
  • In order to verify the effectiveness of adding visooelastic dampers to full-scale steel frame structure on the reduction of their seismic and wind response a experimental work was carried out. First, The test was conducted on the VE dampers subjected to sinusoidal excitations under a variety of ambient temperatures, frequency, and the damper strain. Results from these tests showed that the viscoelastic dampers have high energy dissipation capacity. Second, The vibration tests was conducted of the full-scale steel frame structure with md without added VE dampers at different temperatures. Viscoelastically damped full-scale structure test result on the effect of ambient temperature show that viscoelastic dampers are very effective in reducing excessive vibration of the structure due to sinusoidal excitation over a wide ringe of ambient temperature.

  • PDF

실 구조물 진동제어를 위한 점탄성 댐퍼 설계 및 적용 실험 (Designs and Tests for the Vibration Control of Full-Scale Steel Frame Structure with Added Viscoelastic Dampers)

  • Jeoung Jeoung Kyo;Kim Doo Hoon;Kim Young Chan;Park Jin Il
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.369.1-369
    • /
    • 2002
  • In order to verify the effectiveness of adding viscoelastic dampers to full-scale steel frame structure on the reduction of their seismic and wind response, a experimental work was carried out. First, The test was conducted on the VE dampers subjected to sinusoidal excitations under a variety of ambient temperatures, frequency, and the damper strain. Results from these tests showed that the viscoelastic dampers have high energy dissipation capacity Second, (omitted)

  • PDF

비선형 히스테리시스 댐퍼를 갖는 진동계의 해석 (Non-linear Vibration of a System Incorporating a Hysteretic Damper)

  • 양성영;장서일;김상주
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.531-535
    • /
    • 2000
  • A three-parameter model of viscoelastic damper which has a non-linear spring as an element is incorporated into an oscillator. The behavior of the damper model shows non-linear hysteresis curves which is qualitatively similar to those of real viscoelastic materials. The motion is governed by get analytic solutions of the system. The frequency-response curves show that multiple solutions co-exist and that the jump phenomena can occur. In addition it is shown that separate solution branch exists and that it can merge with the primary response curve. Saddle-node bifurcation sets explain the occurences of such non-linear phenomena. A direct time intergration of the original equation of motion validifies the use of the harmonic balance method to this sort of problem.

  • PDF

An integrated optimal design of energy dissipation structures under wind loads considering SSI effect

  • Zhao, Xuefei;Jiang, Han;Wang, Shuguang
    • Wind and Structures
    • /
    • 제29권2호
    • /
    • pp.99-110
    • /
    • 2019
  • This paper provides a simple numerical method to determine the optimal parameters of tuned mass damper (TMD) and viscoelastic dampers (VEDs) in frame structure for wind vibration control considering the soil-structure interation (SSI) effect in frequency domain. Firstly, the numerical model of frame structure equipped with TMD and VEDs considering SSI effect is established in frequency domain. Then, the genetic algorithm (GA) is applied to obtain the optimal parameters of VEDs and TMD. The optimization process is demonstrated by a 20-storey frame structure supported by pile group for different soil conditions. Two wind resistant systems are considered in the analysis, the Structure-TMD system and the Structure-TMD-VEDs system. The example proves that this method can quickly determine the optimal parameters of energy dissipation devices compared with the traditional finite element method, thus is practically valuable.

점탄성 감쇠기가 설치된 실물크기 5층 건물의 진동실험: 감쇠기의 설계 및 응답실험 (Vibration Test of a Full-Scale Five-Story Structure with Viscoelastic Dampers: Damper Design and Test for Response)

  • 민경원;이상현;김진구;이영철;이승준;김두훈
    • 한국지진공학회논문집
    • /
    • 제7권3호
    • /
    • pp.9-15
    • /
    • 2003
  • 본 논문에서는 동반논문에서 연구된 가진방법과 응답특성을 바탕으로, 실물크기의 철골건물에 설치될 점탄성 감쇠기의 설계과정을 다루었으며 가진실험을 수행하여 감쇠기의 진동제어효과를 검증하였다. 최대변위응답을 주어진 수준까지 감소시키기 위하여 요구되는 추가적인 감쇠비를 컨벡스 모델을 이용하여 구하였다. 모드변형에너지법을 이용하여 감쇠기 강성 변화에 따른 모드 감쇠비의 차이를 분석함으로써 감쇠기의 크기를 구하였다. 가새 강성의 효과 또한 모드의 특성을 구하는 과정에 반영하였다. 점탄성 감쇠기는 1층과 2층의 층간에 각각 2개씩 설치되었으며 응답효과를 검증하였다.

송전선에 의해 송전철탑에 전달되는 풍하중 저감을 위한 회전형 점탄성감쇠기 (Rotational Viscoelastic Dampers for the Mitigation of Wind Loads on Transmission Tower Transferred from Transmission Lines)

  • 문병욱;민경원
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.420-427
    • /
    • 2006
  • In this study, wind loads transmitted to a transmission tower from transmission lines are mitigated using rotational viscoelastic dampers. First, the wind load characteristics in a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower. From the result of the stochastic analysis, the background component of the overturing moment caused by the wind loads acting on the transmission lines are found to have considerable portion in the total overturning moment. Based on this observation result, a strategy Installing rotational viscoelastic damper (VED) between tower arm and transmission line is proposed for the mitigation of the transmission line reactions, which play a role as dynamic loads on a transmission tower. For the purpose of verification, time history analysis is conducted for different wind velocities and VED parameters. The analysis result shows that the rotational VED is effective for the mitigation of the background component rather than the resonance component of the transmission line reactions and achieves the reduction ratio of 50% even for higher wind speed.