• Title/Summary/Keyword: Virtual methods

Search Result 1,407, Processing Time 0.029 seconds

In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

  • Huh, Young-June;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.139-146
    • /
    • 2012
  • Purpose: An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. Materials and Methods: A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. Results: The deviation of the entry point and angulation of the central axis in the reference plane were $0.47{\pm}0.27$ mm, $0.57{\pm}0.23$ mm, and $0.64{\pm}0.16^{\circ}$, $0.57{\pm}0.15^{\circ}$, respectively. However, for the two different angulations in each group, the $20^{\circ}$ angulation showed a greater error in the deviation of the entry point than did the $10^{\circ}$ angulation. Conclusion: The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position (디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과)

  • Kim, Mi-Ja;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-SUk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

A Study on the Statistical GIS for Regional Analysis (지역분석을 위한 웹 기반 통계GIS 연구)

  • 박기호;이양원
    • Spatial Information Research
    • /
    • v.9 no.2
    • /
    • pp.239-261
    • /
    • 2001
  • A large suite of official statistical data sets has been compiled for geographical units under the national directives, and it is the quantitative regional analysis procedures that could add values to them. This paper reports our attempts at prototyping a statistical GIS which is capable of serving over the Web a variety of regional analysis routines as well as value-added statistics and maps. A pilot database of some major statistical data was ingested for the city of Seoul. The baseline subset of regional analysis methods of practical usage was selected and accommodated into the business logic of the target system, which ranges from descriptive statistics, regional structure/inequality measures, spatial ANOVA, spatial (auto) correlation to regression and residual analysis. The leading-edge information technologies including the application server were adopted in the system design and implementation so that the database, analysis modules and analytic mapping components may cooperate seamlessly behind the Web front-end. The prototyped system supports tables, maps, and files of downloadable format for input and output of the analyses. One of the most salient features of out proposed system is that both the database and analysis modules are extensible via the bi-directional interface for end users; The system provides users with operators and parsers for algebraic formulae such that the stored statistical variables may be transformed and combined into the newly-derived set of variables. This functionality eventually leads to on-the-fly fabrication of user-defined regional analysis algorithms. The stored dataset may also be temporarily augmented by user-uploaded dataset; The extension of this form, in essence, results in a virtual database which awaits for users commands as usual. An initial evaluation of the proposed system confirms that the issues involving the usage and dissemination of information can be addressed with success.

  • PDF

A Study on Abroad Export Strategy by Country of Spatial Open Platform -Focused on the Kingdom of Cambodia and the Emirate of Abu Dhabi- (공간정보 오픈플랫폼의 국가별 해외 수출 전략 연구 -캄보디아와 아부다비 에미리트를 중심으로-)

  • Kim, Kirl;Jeong, Jin Do;Lee, Jae Yong
    • Spatial Information Research
    • /
    • v.22 no.3
    • /
    • pp.9-21
    • /
    • 2014
  • Recently the environment in geospatial information has conversed into the plaform. The platform based geospatial information contributes to save time and cost as well as maintain the consistency and stability in spatial data infrastructure. The Republic of Korea is now constructing and operating the spatial open platform called as the V-World(Virtual World), and searching for the possibility of its abroad export. The purpose of this study is to elicit the abroad export strategy by country of spatial open platform by comparing the cases of developing country, the Kingdom of Cambodia and newly developed country, the Emirate of Abu Dhabi, The Kingdom of Cambodia depends on foreign aids to develop the spatial data infrastructure and the Emirate of Abu Dhabi is inducing an advanced technology and high human power from overseas based on abundant oil money. This study establishes the abroad export strategy based on two country models such as Cambodia and Abu Dhabi by considering the characteristics in geospatial information, and suggests the ways of abroad export and the methods on fund raising for spatial open platform.

Path-Planning for Group Movement in Dynamic Environments (동적 환경에서 그룹 이동을 위한 경로 계획)

  • Yu, Kyeonah;Cho, Su-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.2
    • /
    • pp.117-126
    • /
    • 2013
  • Path planning is an essential problem to make virtual characters navigate in many applications including computer games. In many cases, multiple characters move in a group and qualitative aspects of planned paths are emphasized rather than optimality unlike Robotics. In this paper, we propose a two-level path planning algorithm in which the global path is planned for a single character specified as a leader and then the local path is planned to avoid dynamic obstacles while the group following this path. The space for group movement is achieved in the form of square grid array called a grid window. Member characters are located relatively to the leader within a space and moved. The static environment is reduced to the configuration space of this grid window to generate a roadmap on which a grid window can move. In local path planning, only the leader avoids dynamic obstacles by using an artificial potential field and the rest of members are located relatively to the leader in the grid window, which reduces computational load. Efficient algorithms to implement the proposed planning methods are introduced. The simulation results show that a group can handle with dynamic obstacles effectively while moving along the planned path for a static environment.

MEASUREMENT OF MAXILLARY SINUS VOLUME FOR THE PLACEMENT OF GRAFT MATERIAL - A CASE CONTROL STUDY USING CT IMAGE (상악동 골이식술을 위한 이식재의 부피 측정 - CT를 이용한 환자 대조군 연구)

  • Kim, Hyung-Wook;Lee, Seul-Ki;Chung, Jae-An;Shin, Jin-Eob;Um, Yun-Sub;Kim, Ki-Young;Kim, Jong-Sik;Song, Yun-Jung;Hong, Soon-Min;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.511-517
    • /
    • 2007
  • Purpose: The aim of this study is to determine whether a difference in the amount of bone graft material is needed between edentulous patients and dentulous patients and to calculate the amount of augmentation for a sinus lift procedure. Methods: 19 patients(20 sinuses) were included to measure maxillary sinus volume. Facial CT scanning was performed using MX 8000 IDT CT devices(Philips, USA). And it was used for IDLvm(The IDL Virtual Machine) 6.0, CT Volume Analyzer Ver 2.3 program to measure maxillary sinus volumes Results: At edentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.56{\pm}0.13cm^3$(5mm height), $2.35{\pm}0.57cm^3$(10mm height), $4.85{\pm}1.10cm^3$(15mm height). At dentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.41{\pm}0.18cm^3$(5mm height), $1.76{\pm}0.42cm^3$(10mm height), $3.80{\pm}0.84cm^3$ (15mm height). A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume.(p=0.027, p=0.018, p=0.044) Conclusions: A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume. Detailed preoperative knowledge of sinus lift augmentation volume is helpful in determining the appropriate amount of the bone graft material.

Planning of Optimal Work Path for Minimizing Exposure Dose During Radiation Work in Radwaste Storage (방사성 폐기물 저장시설에서의 방사선 작업 중 피폭선량 최소화를 위한 최적 작업경로 계획)

  • Park, Won-Man;Kim, Kyung-Soo;Whang, Joo-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.17-25
    • /
    • 2005
  • Since the safety of nuclear power plant has been becoming a big social issue the exposure dose of radiation for workers has been one of the important factors concerning the safety problem. The existing calculation methods of radiation dose used in the planning of radiation work assume that dose rate does not depend on the location within a work space thus the variation of exposure dose by different work path is not considered. In this study, a modified numerical method was presented to estimate the exposure dose during radiation work in radwaste storage considering the effects of the distance between a worker and sources. And a new numerical algorithm was suggested to search the optimal work path minimizing the exposure dose in pre-defined work space with given radiation sources. Finally, a virtual work simulation program was developed to visualize the exposure dose of radiation doting radiation works in radwaste storage and provide the capability of simulation for work planning. As a numerical example, a test radiation work was simulated under given space and two radiation sources, and the suggested optimal work path was compared with three predefined work paths. The optimal work path obtained in the study could reduce the exposure dose for the given test work. Based on the results, tile developed numerical method and simulation program could be useful tools in the planning of radiation work.

Development of FURA Code and Application for Load Follow Operation (FURA 코드 개발과 부하 추종 운전에 대한 적용)

  • Park, Young-Seob;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.88-104
    • /
    • 1988
  • The FUel Rod Analysis(FURA) code is developed using two-dimensional finite element methods for axisymmetric and plane stress analysis of fuel rod. It predicts the thermal and mechanical behavior of fuel rod during normal and load follow operations. To evaluate the exact temperature distribution and the inner gas pressure, the radial deformation of pellet and clad, the fission gas release are considered over the full-length of fuel rod. The thermal element equation is derived using Galerkin's techniques. The displacement element equation is derived using the principle of virtual works. The mechanical analysis can accommodate various components of strain: elastic, plastic, creep and thermal strain as well as strain due to swelling, relocation and densification. The 4-node quadratic isoparametric elements are adopted, and the geometric model is confined to a half-pellet-height region with the assumption that pellet-pellet interaction is symmetrical. The pellet cracking and crack healing, pellet-cladding interaction are modelled. The Newton-Raphson iteration with an implicit algorithm is applied to perform the analysis of non-linear material behavior accurately and stably. The pellet and cladding model has been compared with both analytical solutions and experimental results. The observed and predicted results are in good agreement. The general behavior of fuel rod is calculated by axisymmetric system and the cladding behavior against radial crack is used by plane stress system. The sensitivity of strain aging of PWR fuel cladding tube due to load following is evaluated in terms of linear power, load cycle frequency and amplitude.

  • PDF

Developing and Valuating 3D Building Models Based on Multi Sensor Data (LiDAR, Digital Image and Digital Map) (멀티센서 데이터를 이용한 건물의 3차원 모델링 기법 개발 및 평가)

  • Wie, Gwang-Jae;Kim, Eun-Young;Yun, Hong-Sic;Kang, In-Gu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2007
  • Modeling 3D buildings is an essential process to revive the real world into a computer. There are two ways to create a 3D building model. The first method is to use the building layer of 1:1000 digital maps based on high density point data gained from airborne laser surveying. The second method is to use LiDAR point data with digital images achieved with LiDAR. In this research we tested one sheet area of 1:1000 digital map with both methods to process a 3D building model. We have developed a process, analyzed quantitatively and evaluated the efficiency, accuracy, and reality. The resulted differed depending on the buildings shape. The first method was effective on simple buildings, and the second method was effective on complicated buildings. Also, we evaluated the accuracy of the produced model. Comparing the 3D building based on LiDAR data and digital image with digital maps, the horizontal accuracy was within ${\pm}50cm$. From the above we derived a conclusion that 3D building modeling is more effective when it is based on LiDAR data and digital maps. Using produced 3D building modeling data, we will be utilized as digital contents in various fields like 3D GIS, U-City, telematics, navigation, virtual reality and games etc.

A study of incidence of palatal side abfractions in maxillary posterior teeth (상악 구치에서의 구개측 굴곡파절 발현 비율 연구)

  • Song, Joo-Hun;Heo, Yuri;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.206-213
    • /
    • 2019
  • Purpose: Most of studies dealing with abfractions are limited to the buccal surfaces of the teeth. In this study, we analyzed the cause for abfraction by investigating the incidence of palatal side abfractions in maxillary posterior teeth. Materials and Methods: We investigated a total of 3193 maxillary posterior teeth by an intraoral examination, model observation, and observation of virtual model fabricated using model scanning. We recorded the results and classified them depending on the type of teeth, age, gender, and side of arches. We also performed Chi-square test to evaluate the statistical significance among the groups (α = 0.05). Results: The incidence of palatal side abfraction of the maxillary molars (10.8%) was higher than the premolars (6.8%), and among them, the incidence of the 1st molars (39.1%) were the highest. The incidence of palatal side abfraction increased with age and was statistically significant (P < 0.05). There was no statistical significance in the difference by gender (P > 0.05); in the case of arches, left arch showed higher incidence and it was statistically significant (P < 0.05). Conclusion: Palatal side abfraction in maxillary posterior teeth was frequently observed in the maxillary 1st molars, and the incidence increased with age. This result suggests that the main reason for abfraction is due to occlusal force.